SMR System 1375.15.605Recalls & reported problems

Limacorporate SPA · SMR System - TT Baseplate Small-R · Class 2 · Implant

All models of SMR System (47)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08033390272797), received between Feb 12, 2026 and Jun 22, 2026 — classified as 3 injuries.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 2 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Patient Device Interaction Problem3
  • Detachment of Device or Device Component1
  • Mechanical Problem1

Patient problems

  • Joint Laxity2
  • Loose body in joint2

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 22, 2026Patient Device Interaction Problem

    REVISION SURGERY WAS PERFORMED ON (B)(6) 2026 DUE TO GLENOID LOOSENING IN A STUDY PATIENT. ORIGINAL SURGERY WAS PERFORMED ON (B)(6) 2026 WHEN THE FOLLOWING ASSEMBLY HAS BEEN IMPLANTED: GLENOID BASEPLATE SMALL-R (PN 1375.15.605, LOT 2536262, STERILIZATION (B)(4)), GLENOID PEG SMALL-R #S (PN 1375.14.651, LOT 2515773, STERILIZATION (B)(4)), 2X BONE SCREW (PN 8420.15.010, LOTS 2530046 AND 2523197, STERILIZATION (B)(4) RESPECTIVELY), CONNECTOR SMALL +2MM (PN 1374.15.312, LOT 2513801, STERILIZATION (B)(4)), REVERSE HP GLENOSPHERE (PN 1374.50.440, LOT 2228852, STERILIZATION (B)(4)), SMR STEMLESS REVERSE CORE #L (PN 1355.14.238, LOT 2119985, STERILIZATION (B)(4)), SMR STEMLESS REVERSE LINER #S (PN 1365.09.445, LOT 2222639, STERILIZATION (B)(4)). NO ADVERSE EVENTS OCCURRED DURING SURGICAL PROCEDURE AND SURGEON USED A DELTO-PECTORAL APPROACH. MIGRATION OF THE BASEPLATE WAS NOTICED IN THE EARLY POST OPERATIVE PERIOD (AROUND 6 WEEKS POST OP). PATIENT WAS OPERATING TRACTORS AGAINST MEDICAL ADVICE. THE WHOLE ASSEMBLY HAS BEEN REMOVED DURING REVISION AND REPLACED WITH DJO ALTIVATE REVERSE. THE EVENT OCCURRED IN THE UNITED STATES.

    Patient problems: Joint Laxity

    MAUDE report 25573951 ↗
  • InjuryFeb 12, 2026Patient Device Interaction Problem

    REVISION SURGERY WAS PERFORMED ON (B)(6) 2025 DUE TO COMPONENT LOOSENING. PREVIOUS SURGERY WAS PERFORMED ON (B)(6) 2025 TO IMPLANT FOLLOWING COMPONENTS: PRIMA STEM #2 (PN 1357.14.030, LOT 2224208, STERILIZATION (B)(4)), PRIMA REVERSE TRAY #MEDIUM (PN 1367.15.013, LOT 2419312, STERILIZATION (B)(4)), PRIMA REVERSE INSERT SHORT DIA36MM 0*CORR RETENTIVE (PN 1367.54.101, LOT 2124961, STERILIZATION (B)(4)), SMR TT BASEPLATE SMALL-R (PN 1375.15.605, LOT 2430324, STERILIZATION (B)(4)), SMR GLENOID PEG TT SMALL-R SHORT (PN 1375.14.651, LOT 2331269, STERILIZATION (B)(4)), SMR CONNECTOR SMALL-R (PN 1374.15.305, LOT 2430893, STERILIZATION (B)(4)), SMR GLENOSPHERE DIA36MM (PN 1374.09.111, LOT 2429216, STERILIZATION (B)(4)). DURING REVISION THE SURGEON REMOVED ALL ABOVE-MENTIONED GLENOID COMPONENTS, AS WELL AS THE REVERSE TRAY AND LINER TO IMPLANT A 6MM ECCENTRICAL ADAPTOR (PN 1367.15.706) AND A HUMERAL HEAD DIA46MM (PN 13.22.09.460) AND CONVERT THE PROSTHESIS FROM A REVERSE TO AN ANATOMIC CONFIGURATION. SURGERY WAS COMPLETED AS INTENDED. PATIENT IS FEMALE, DATE OF BIRTH (B)(6) 1951. THE EVENT OCCURRED IN THE UNITED STATES.

    Patient problems: Loose body in joint

    MAUDE report 24322375 ↗
  • InjuryFeb 12, 2026Mechanical Problem; Detachment of Device or Device Component; Patient Device Interaction Problem

    REVISION SURGERY WAS PERFORMED ON (B)(6) 2025 DUE TO GLENOID FAILURE. DURING REVISION, THE FOLLOWING PRE-EXISTING SHOULDER PROSTHESIS COMPONENTS WERE REMOVED: SMR GLENOID BASEPLATE SMALL-R (PN 1375.15.605, LOT 2511769, STERILIZATION (B)(4)), SMR GLENOID PEG TT SMALL-R #M (PN 1375.14.652, LOT 2514981, STERILIZATION (B)(4)), SMR CONNECTOR SMALL R (PN 1374.15.305, LOT 2509762, STERILIZATION (B)(4)), SMR GLENOSPHERE Ø 36MM (PN 1374.09.111, LOT 2512612, STERILIZATION (B)(4)), SMR REVERSE LINER + 6 MM (PN 1360.50.820, LOT 24AT5NV, STERILIZATION (B)(4)). SURGEON CONVERTED THE REMOVED REVERSE ASSEMBLY TO AN ANATOMIC CONFIGURATION IMPLANTING AN ADAPTOR 36MM FOR REVERSE BODY (PN 1352.15.200) AND A CTA HEAD DIA46MM (PN 1323.09.460). THE SURGERY WAS COMPLETED AS INTENDED. PREVIOUS SURGERY IS UNKNOWN. THE PATIENT IS FEMALE, DATE OF BIRTH (B)(6) 1943. THE EVENT OCCURRED IN THE UNITED STATES.

    Patient problems: Joint Laxity; Loose body in joint

    MAUDE report 24322374 ↗

Other Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented devices

All Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented devices →