PACIFIC XTREME PCU070200130 (UDI 08033477035383)Recalls & reported problems
Medtronic, Inc. · Cath PCU070200130 PCU US 07.00L200UL1300 · Class 2
All models of PACIFIC XTREME (25)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033477035383), received between Feb 14, 2017 and Feb 14, 2017 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Distortion” (1 report).
1 other recall cover devices cleared under the same FDA submission (K103464); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Distortion1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 14, 2017Material Distortion; Material Distortion
PHYSICIAN ATTEMPTED TO TREAT PATIENT AT THE LEFT, DISTAL SUPERFICIAL FEMORAL ARTERY USING A PACIFIC XTREME BALLOON. TARGET LESION WAS CALCIFIED AND FIBROUS WITH LITTLE TORTUOSITY, MODERATE CALCIFICATION AND 75% STENOSIS. ARTERY DIAMETER WAS 7 MM AND LESION LENGTH WAS 300 MM. IT IS REPORTED THAT WHEN INFLATING THE BALLOON TO 4 ATM USING AN INFLATION DEVICE AND FLUID (1:1, HEP SALINE: CONTRAST) A BALLOON TWIST OCCURRED. THE BALLOON WAS USED DURING 3 SEPARATE INFLATIONS, WITH THE TWIST BEING OBSERVED IN EVERY INFLATION.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6329170 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K103464. One submission often covers many models, so check the product and lot details in each record.
- Z-3055-2020 · Aug 26, 2020 · TerminatedPacific Xtreme (PTCA Balloon Dilation Catheter)
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page