ADMIRAL XTREME ADM070040080Recalls & reported problems
Medtronic, Inc. · CATH ADM070040080 ADM US 07 00L40 UL0800 · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033477058078), received between Oct 7, 2017 and Oct 7, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Burst Container or Vessel” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Burst Container or Vessel1
Patient problems
- Patient Problem/Medical Problem1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 7, 2017Burst Container or Vessel; Burst Container or Vessel
THE PHYSICIAN INTENDED TO USE THE ADMIRAL XTREME PTA TO TREAT THE RIGHT ILIAC ARTERY. IT WAS REPORTED THE BALLOON WAS ADVANCED TO THE LESION, AND INFLATED ACROSS THE RIGHT ILIAC LESION AT 8 ATMOSPHERES FOR 60 SECONDS. DURING THE SECOND INFLATION AFTER 3 MINUTES THE BALLOON RUPTURED AT NOMINAL PRESSURE. THE BALLOON WAS REMOVED OVER A WIRE, IT WAS OBSERVED AFTER REMOVAL THAT A FRAGMENT OF THE BALLOON WAS CAUGHT AT THE SHEATH. THE PHYSICIAN PULLED THE SHEATH SLIGHTLY BACK AND WITH A BLADE CUT DOWN AND WITH HEMOSTATS RETRIEVED THE FRAGMENTED BALLOON PIECE. THE SHEATH WAS ADVANCED BACK AND HELD PRESSURE. THE SITE CONTINUED TO BLEED THE PHYSICIAN UPSIZED THE SHEATH FROM A 5F,6F,7F,8F TO A 9F SHEATH AND APPLIED PRESSURE. THE SIGHT STOPPED BLEEDING WITH NO FURTHER ISSUES REPORTED.
Patient problems: Patient Problem/Medical Problem
MAUDE report 6926171 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page