Skip to content

Steelco ID 300/2Recalls & reported problems

Steelco SPA · This device drying cabinet provides fast drying of instruments, equipment and general item. Items are stored in controlled environment. · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08051520012693), received between Dec 29, 2025 and Dec 29, 2025 — classified as 1 malfunction.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Appropriate Device Problem Term/Code Not Available1

Patient problems

  • Keratitis1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 29, 2025Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    WHILE TROUBLESHOOTING AN ID 300/2 DRYING CABINET THAT DISPLAYED AN ERROR RELATED TO THE UV LAMP, THE TECHNICIAN REMOVED THE BPA FILTER TO CHECK IF ALL THREE LAMPS WERE FUNCTIONING. THE TECHNICIAN OBSERVED THE LAMPS FOR LESS THAN FIVE SECONDS ON THREE SEPARATE OCCASIONS BEFORE CLOSING THE SYSTEM. EXPOSURE TO THE UV LIGHT, EVEN FOR THESE BRIEF MOMENTS, RESULTED IN MILD PHOTOKERATITIS (A SENSATION SIMILAR TO HAVING SAND IN THE EYES). THE IRRITATION WAS TEMPORARY, WITH NO PERMANENT DAMAGE, AND VISION RETURNED TO NORMAL. ACCORDING TO THE DOCTOR'S NOTE, THE TECHNICIAN WAS CLEARED TO RETURN TO WORK THE SAME DAY. NO PATIENTS WERE INVOLVED IN THIS INCIDENT.

    Patient problems: Keratitis

    MAUDE report 23907476 ↗

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page