DEKA SYNCHRO REPLA:Y EXCELLIUM 3.4 M104K1Recalls & reported problems
El.En. SPA · The Synchro Repla:y Excellium 3.4 is a medical laser workstation equipped with an High power Alexandrite 755 nm laser and an high power Nd:YAG 1064 nm laser. The system can also be equipped with a pulsed light handpieces. · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08057017760108), received between Nov 16, 2016 and Nov 16, 2016 — classified as 1 injury.
The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Incorrect, Inadequate or Imprecise Result or Readings1
Patient problems
- Burn(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 16, 2016Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
(B)(4) SALES AGENT FOR (B)(6) MR. (B)(6) NOTICED US ABOUT AN ADVERSE EVENT HE RECENTLY BECAME AWARE OF. INVOLVED DEVICE IS DEKA SYNCHRO REPLAY EXCELLIUM 3.4 MODEL NUMBER M104H1, S/N (B)(4), MANUFACTURED BY (B)(4). THE ACTUAL DATE OF THE EVENT IS UNKNOWN (BEST ESTIMATE DATE OF THE EVENT (B)(6) 2016) AND (B)(4) BECAME AWARE OF THE EVENT ON (B)(6) 2016. EVENT TOOK PLACE IN THE (B)(6). OUR SERVICE TECHNICIAN VISITED THE CUSTOMER AND INFORMED US THAT ONE DEKA SYNCHRO REPLAY EXCELLIUM 3.4 WAS INVOLVED IN A LASER TREATMENT FOR FACE BENIGN PIGMENTATED LESIONS (DARK SPOT ON CHEEK) ON PATIENT WHO DEVELOPED A BURN ON CHEEK. WE, THE MANUFACTURER OF THE DEVICE DEKA SYNCHRO REPLAY EXCELLIUM 3.4 MARKETED IN THE US TERRITORY, ACCORDING TO 21 CFR 803.50 SUBMITTED TO FDA AN OWN INITIAL 30 DAYS MDR REPORT. THIS EVENT IS REPORTED TO FDA IN THE SIDE ORF CAUTION DUE TO THE FACT THAT WE DID NOT HAVE ANY INFORMATION CONCERNING THE STATE OF HEALING OF THE PATIENT AT THE TIME AND THAN WE CONSIDER THE BURN AS A POTENTIAL EVOLVING TO A PERMANENT DAMAGE.
Patient problems: Burn(s)
MAUDE report 6105783 ↗
Other Powered Laser Surgical Instrument devices
- Moxy 0010-2400Boston Scientific Corporation · Powered Laser Surgical Instrument4,572 reports
- SOLTIVE TFL-PLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls450 reports
- Flexiva TracTip M0068403960Boston Scientific Corporation · Powered laser surgical instrument562 reports
- Moses™ AC-10030100Lumenis Ltd. · Powered Laser Surgical Instrument532 reports
- Flexiva M0068403910Boston Scientific Corporation · Powered laser surgical instrument376 reports
- Visualase 9735542Medtronic Navigation, Inc. · Powered laser surgical instrument1 recall2 deaths311 reports
- SOLTIVE TFL-SLSGyrus ACMI, LLC · Powered laser surgical instrument6 recalls33 reports
- NeuroBlate® System 20980Monteris Medical Inc · Powered laser surgical instrument7 deaths296 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page