V-STEADY 800039Recalls & reported problems

G21 Srl · Radiopaque Bone Cement for vertebral consolidation · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08058964723819), received between May 15, 2024 and May 15, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Migration” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Migration1

Patient problems

  • Pulmonary Embolism1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 15, 2024Migration; Migration

    ON (B)(6) 2021 FLUOROSCOPY GUIDED KYPHOPLASTY AT THE T3/T4 USING V-STEADY BONE CEMENT TO STABILIZE VERTEBRAL BODIES OCCURRED ON PATIENT. SURGEON STATES "RADIOGRAPHS WERE OBTAINED THAT SHOWED GOOD FILLING WITH NO POSTERIOR EXTRAVASATION INTO THE SPINAL CANAL" AND "FINAL RADIOGRAPHS WERE OBTAINED THAT DEMONSTRATED APPROPRIATE FILLING PATTERNS." THE FOLLOWING DAY THE PATIENT RETURNED TO THE ER WITH PAINFUL BREATHING UPON INHALATION, AND EXPERIENCED PAIN IN HER THORACIC AREA WITH COUGHING, ANY MOVEMENT, AND BREATHING. PATIENT'S COMPLICATIONS PERSISTED AND ON (B)(6) 2021 A CT WITH CONTRAST SHOWED EXTRAVASATION OF METHYL METHACRYLATE SHOWING EVIDENCE THAT CEMENT WAS PROPAGATING FROM THE T7 VERTEBRAL BODY INTO A PERIVERTEBRAL DRAINING VEIN AND INTO/AROUND/NEAR THE HEART. AN ECHO (TTE X 4) WAS PERFORMED WHICH CONFIRMED THAT THERE WAS CEMENT IN THE VEINS TO PATIENT'S HEART. PHYSICIAN STATED THE CEMENT LEAKED INTO THE AZYGOS VEIN INTO THE MAIN ATRIUM IN THE HEART. THE CT SCAN REVEALED: "1. LONG LINEAR HYPERDENSE MATERIAL EXTENDING FROM THE T3 AND AND T4 VERTEBRAL BODIES (STATUS POST CEMENT AUGMENTATION), THROUGH THE RIGHT AZYGOS, RIGHT ATRIUM, AND RIGHT VENTRICLE. THIS IS FAVORED TO ALL REPR

    Patient problems: Pulmonary Embolism

    MAUDE report 19323097 ↗

FDA clearance and classification

Cleared through 510(k) K150408 on Dec 14, 2015 (decision: Substantially Equivalent). Submitted by G21, S.R.L. as “V-Steady, V-Fast”. The FDA review took 299 days. FDA record ↗

The FDA regulates product code NDN (cement, bone, vertebroplasty) under 21 CFR 888.3027 as a Class II device. 21 CFR 888.3027 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the V-STEADY 800039

Has the V-STEADY 800039 been recalled?

No FDA recall record in our data names this exact device identifier (DI 08058964723819), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the V-STEADY 800039?

The FDA's MAUDE database lists 1 adverse event report for this device, received on May 15, 2024. That report lists device problem “Migration” (1); patient problem “Pulmonary Embolism” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the V-STEADY 800039?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the V-STEADY 800039 FDA approved?

It was cleared through 510(k) K150408 on Dec 14, 2015. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the V-STEADY 800039 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the V-STEADY 800039, and is it still sold?

The FDA's device database lists G21 Srl as the company responsible for it (brand V-STEADY, model 800039). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Cement, Bone, Vertebroplasty devices

All Cement, Bone, Vertebroplasty devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page