TREO Abdominal Stent-Graft System 28-L2-11-100URecalls & reported problems
Bolton Medical Inc. · Endovascular Stent-Graft System · Class 3 · Implant
All models of TREO Abdominal Stent-Graft System (73)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 08435761052050), received between Dec 5, 2024 and Dec 5, 2024 — classified as 2 injuries.
The most frequently reported specific device problem is “Device Stenosis” (2 reports).
1 other recall cover devices cleared under the same FDA submission (P190015); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Stenosis2
Patient problems
- Stenosis2
- Thrombosis/Thrombus2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryDec 5, 2024Device Stenosis; Device Stenosis
"(B)(6) HAD THEIR 3-YEAR FOLLOW-UP ON (B)(6)2024 AND RECENTLY DEVELOPED INCREASING CLAUDICATION SYMPTOMS ON THE RIGHT LEG THAT WERE DEBILITATING AND DIAGNOSED AS PROGRESSIVE EXTERNAL ILIAC OCCLUSIVE DISEASE. THE CT DATED (B)(6)2024 REFLECTED NO ENDOLEAKS, HOWEVER PER THE PI, THE CT "INDICATED THE ENDOGRAFT IN GOOD POSITION WITH SUCCESSFUL EXCLUSION OF ANEURYSM BUT THERE WAS A HIGH-GRADE STENOSIS OF THE OUTFLOW RIGHT EXTERNAL ILIAC ARTERY IN ITS PROXIMAL SEGMENT. THIS WAS FELT TO BE SEVERE AND COULD COMPROMISE FUNCTION IN THE GRAFT". ADDITIONALLY, THE STENOSIS "EXCEEDED 80% IF NOT 90%" POSING A RISK OF OCCLUSION WITH PROBABLE THROMBOSIS OF THE RIGHT LIMB OF THE GRAFT AND SEVERE ISCHEMIA. ON (B)(6)2024, THE SUBJECT UNDERWENT OUTPATIENT SURGERY INVOLVING AN ANGIOPLASTY WITH A 7MM BALLOON AND STENTING OF RIGHT EXTERNAL ILIAC ARTERY USING A 12X4 SMART STENT. THERE WERE NO COMPLICATIONS AND THE COMPLETION ANGIO REFLECTED THE RIGHT EXTERNAL ILIAC ARTERY AS WIDELY PATENT WITH NO RESIDUAL NARROWING." PATIENT OUTCOME: "THE SUBJECT WAS SEEN ON (B)(6)2024 AND HAD AN ULTRASOUND (US) ANKLE/BRACHIAL CONDUCTED SAME DAY REFLECTING AN IMPROVED ANKLE BRACHIAL INDEX (ABI) ON THE RIGHT SIDE AND NO FURT
Patient problems: Stenosis; Thrombosis/Thrombus
MAUDE report 20858394 ↗InjuryDec 5, 2024Device Stenosis; Device Stenosis
"SUBJECT (B)(6) HAD THEIR 3-YEAR FOLLOW-UP ON (B)(6) 2024 AND RECENTLY DEVELOPED INCREASING CLAUDICATION SYMPTOMS ON THE RIGHT LEG THAT WERE DEBILITATING AND DIAGNOSED AS PROGRESSIVE EXTERNAL ILIAC OCCLUSIVE DISEASE. THE CT DATED (B)(6) 2024 REFLECTED NO ENDOLEAKS, HOWEVER PER THE PI, THE CT "INDICATED THE ENDOGRAFT IN GOOD POSITION WITH SUCCESSFUL EXCLUSION OF ANEURYSM BUT THERE WAS A HIGH-GRADE STENOSIS OF THE OUTFLOW RIGHT EXTERNAL ILIAC ARTERY IN ITS PROXIMAL SEGMENT. THIS WAS FELT TO BE SEVERE AND COULD COMPROMISE FUNCTION IN THE GRAFT". ADDITIONALLY, THE STENOSIS "EXCEEDED 80% IF NOT 90%" POSING A RISK OF OCCLUSION WITH PROBABLE THROMBOSIS OF THE RIGHT LIMB OF THE GRAFT AND SEVERE ISCHEMIA. ON (B)(6) 2024, THE SUBJECT UNDERWENT OUTPATIENT SURGERY INVOLVING AN ANGIOPLASTY WITH A 7MM BALLOON AND STENTING OF RIGHT EXTERNAL ILIAC ARTERY USING A 12X4 SMART STENT. THERE WERE NO COMPLICATIONS AND THE COMPLETION ANGIO REFLECTED THE RIGHT EXTERNAL ILIAC ARTERY AS WIDELY PATENT WITH NO RESIDUAL NARROWING." PATIENT OUTCOME: "THE SUBJECT WAS SEEN ON (B)(6) 2024 AND HAD AN ULTRASOUND (US) ANKLE/BRACHIAL CONDUCTED SAME DAY REFLECTING AN IMPROVED ANKLE BRACHIAL INDEX (ABI) ON THE RIGHT SIDE
Patient problems: Stenosis; Thrombosis/Thrombus
MAUDE report 20857814 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P190015. One submission often covers many models, so check the product and lot details in each record.
- Z-1689-2023 · May 3, 2023 · Open, ClassifiedThe TREO ABDOMINAL STENT-GRAFT SYSTEM (TREO) consists of four types of implants, specifically a Main Bifurcated Stent-Graft, a Leg Extension Stent-Graft, a Proximal Cuff Stent-Graf
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page