TREO Abdominal Stent-Graft System 28-B2-24-080U (UDI 08435761052340)Recalls & reported problems
Bolton Medical Inc. · Endovascular Stent-Graft System · Class 3 · Implant
All models of TREO Abdominal Stent-Graft System (73)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 1
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08435761052340), received between Dec 3, 2024 and Jul 27, 2026 — classified as 1 death, 2 injuries.
The most frequently reported specific device problem is “Device Endoleak” (1 report).
1 other recall cover devices cleared under the same FDA submission (P190015); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Device Endoleak1
- Fracture1
- Insufficient Device Problem Information1
- No Apparent Adverse Event1
- Patient Device Interaction Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Clinical Endoleak1
- Insufficient Information1
- Thrombosis/Thrombus1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryJul 27, 2026Fracture
"The Core Lab sent notification on (b)(6) 2026 having identified a barb break at the proximal aspect of the uncovered stent for subject (b)(6) 4-year imaging dated (b)(6) 2026. Additional information received on 07/02/2026:The subject's 4-year follow-up occurred same day and remains asymptomatic from an aneurysmal perspective without Endo leaks and stable size of residual aneurysm sac. There were no AEs that occurred as a result of this barb break identified by the Core Lab.The PI reviewed the imaging and did not identify any stent graft integrity issues, therefore no device deficiency reported by the site. The x-ray report also states 'no gross evidence of migration or stent fracture'."Patient Outciome: "Pending details from the site regarding status of subject or if any AEs have occurred as a result of."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50017622 ↗DeathJan 27, 2025Adverse Event Without Identified Device or Use Problem; No Apparent Adverse Event; Insufficient Device Problem Information; Device Endoleak; Adverse Event Without Identified Device or Use Problem; No Apparent Adverse Event; Insufficient Device Problem Information; Device Endoleak
"SUBJECT (B)(6) WAS CONTACTED ON (B)(6)2024 TO SCHEDULE THEIR 2-YEAR FOLLOW-UP, AND THE SITE WAS TOLD BY THE SUBJECT'S SPOUSE THAT THE SUBJECT HAD PASSED AWAY AT HOME ON (B)(6)2024. THE CAUSE OF DEATH WAS PREVIOUSLY UNKNOWN DUE TO SIGNIFICANT SITE DIFFICULTIES OBTAINING ANY SOURCE. THE DEATH CERTIFICATE WAS RECENTLY OBTAINED CONFIRMING THE DATE OF DEATH AND CAUSE OF DEATH STATES ABDOMINAL AORTIC ANEURYSM. THE DEVICE RELATEDNESS IS PENDING ASSESSMENT BY THE PRINCIPAL INVESTIGATOR. FURTHER, THE SITE IS STILL ATTEMPTING TO OBTAIN POSSIBLE HOSPITALIZATION SOURCE FROM AN OUTSIDE INSTITUTION WHICH OCCURRED SHORTLY PRIOR TO THE SUBJECT'S DEATH TO FURTHER REVIEW AGAINST THE DEATH CERTIFICATE." PATIENT OUTCOME: "SUBJECT DEATH AS NOTED ABOVE."
Patient problems: Clinical Endoleak; Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 21242892 ↗InjuryDec 3, 2024Patient Device Interaction Problem; Patient Device Interaction Problem
"SUBJECT (B)(6) HAD THEIR 3-YEAR FOLLOW-UP ON 03JUL2024 WHERE IT WAS NOTED THAT HE HAD NO CHANGES IN HEALTH OTHER THAN NEW CLAUDICATION IN HIS LEFT LEG. THE CT DATED (B)(6) 2024 REFLECTED A NEW COMPLETE OCCLUSION OF THE LEFT ILIAC LIMB WHICH WAS 100% PATENT ON THEIR 2-YEAR IMAGING DATED (B)(6) 2023. THE REMAINDER OF THE DEVICE WAS PATENT, COMPLETE SAC REGRESSION, AND NO ENDOLEAK. DISTAL TO THE STENT GRAFT, THE LEFT COMMON, EXTERNAL, AND INTERNAL ILIAC ARTERIES ARE PATENT LIKELY VIA COLLATERALS. THE INVESTIGATOR DEEMED THE EVENT SERIOUS FOR THE CRITERIA "PERMANENT IMPAIRMENT OF A BODY STRUCTURE OR BODY FUNCTION", AND RELATED TO THE DEVICE, SPECIFICALLY ILIAC LEG. THE SUBJECT STATED THAT THE CLAUDICATION SYMPTOMS WERE NOT SEVERE ENOUGH AND DENIED SURGERY TO CORRECT IT AT THAT TIME. THE SUBJECT AGREED TO NOTIFY THE SITE IF HE DECIDED TO HAVE HIS CLAUDICATION TREATED IN THE FUTURE." PATIENT OUTCOME: "AS OF NOVEMBER 2024, THE SUBJECT HAS NOT CONTACTED THE SITE NOR HAD ANY ADDITIONAL FOLLOW-UPS TO DISCUSS PLANS FOR RE-INTERVENTION."
Patient problems: Thrombosis/Thrombus
MAUDE report 20831430 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P190015. One submission often covers many models, so check the product and lot details in each record.
- Z-1689-2023 · May 3, 2023 · Open, ClassifiedThe TREO ABDOMINAL STENT-GRAFT SYSTEM (TREO) consists of four types of implants, specifically a Main Bifurcated Stent-Graft, a Leg Extension Stent-Graft, a Proximal Cuff Stent-Graf
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page