Blazer® II M0045031TK10Recalls & reported problems
Boston Scientific Corporation · Temperature Ablation Catheter · Class 3
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 08714729082439), received between Jul 12, 2019 and Aug 23, 2022 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Defective Device” (1 report).
3 other recalls cover devices cleared under the same FDA submission (P920047); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Defective Device1
- Difficult to Remove1
- Failure to Deliver Energy1
Patient problems
- Device Embedded In Tissue or Plaque1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 23, 2022Failure to Deliver Energy; Defective Device; Failure to Deliver Energy; Defective Device
IT WAS REPORTED THAT DURING A CARDIAC RADIOFREQUENCY ABLATION, A BLAZER II CATHETER WAS SELECTED FOR USE. DURING THE PROCEDURE, ABLATION THE DISCHARGE WAS ABNORMAL, AND THE ADJUSTMENT OF THE TAIL LINE COULD NOT BE SOLVED. THE CATHETER WAS REPLACED AND THE PROCEDURE WAS COMPLETED WITHOUT ANY PATIENT COMPLICATIONS. THIS CATHETER IS EXPECTED TO BE RETURNED FOR LABORATORY ANALYSIS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15276427 ↗InjuryJul 12, 2019Difficult to Remove; Difficult to Remove
IT WAS REPORTED THAT THE DEVICE WAS DIFFICULT TO WITHDRAW. DURING AN ABLATION PROCEDURE FOR WOLFF-PARKINSON-WHITE (WPW) SYNDROME, ABLATION WAS PERFORMED OF THE LEFT ATRIUM MITRAL VALVE ANNULUS WITH A BLAZER II CATHETER. THE PROCEDURE WAS STARTED BY APPROACHING FROM THE AORTA. WHEN THE CATHETER WAS REMOVED FROM THE LEFT ATRIUM AFTER COMPLETING THE ABLATION, THE TIP OF THE CATHETER WAS TANGLED WITH THE A VALVE CHORD AND IT BECAME UNABLE TO REMOVE. THE CATHETER WAS PLANNED TO BE REMOVED BY SURGICAL THORACOTOMY. WITH REGARDS TO CATHETER REMOVAL SURGICALLY, THE CATHETER COULD NOT BE REMOVED FROM THE "AO SIDE", BUT THE CATHETER COULD BE REMOVED BY PULLING IT OUT FROM THE VENTRICULAR SIDE. IT WAS ALSO REPORTED THAT THE DEVICE "REMAINED INSIDE" THE PATIENT. THE PROCEDURE WAS CANCELLED. THE PATIENT WAS "STILL ALIVE."
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 8784341 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P920047. One submission often covers many models, so check the product and lot details in each record.
- Z-0202-2019 · Jun 20, 2018 · Open, ClassifiedBoston Scientific Maestro 4000 Cardiac Ablation System, Firmware Version 5.14, Model Numbers: M00440000, M0044000D0, M0044000H0,M0044000R0, M0044000Z0,
- Z-0973-2011 · Jul 14, 2009 · TerminatedRF Ablation System Foot Switch, used with the EPT-1000 RF Generator, Foot Switch Model Number UPN M0048400, and in kits with UPNs M0044810 and M0044811. Intended use: The EPT-1000
- Z-1617-2008 · Feb 14, 2008 · TerminatedBoston Scientific SteeroCath-T Ablation Catheter. This catheter is indicated for general indications, treatment of supraventricular tachycardia (svt) and ventricular tachycardia (
Other Cardiac ablation percutaneous catheter devices
- THERMOCOOL SMARTTOUCH SF D134805Biosense Webster Inc · Cardiac ablation percutaneous catheter1 recall176 deaths4,106 reports
- THERMOCOOL SMARTTOUCH SF D134804Biosense Webster Inc · Cardiac ablation percutaneous catheter44 deaths784 reports
- THERMOCOOL SMARTTOUCH SF D134801Biosense Webster Inc · Cardiac ablation percutaneous catheter15 deaths608 reports
- ThermoCool SmartTouch D132705Biosense Webster Inc · Cardiac ablation percutaneous catheter25 deaths574 reports
- THERMOCOOL SMARTTOUCH SF D134702Biosense Webster Inc · Cardiac ablation percutaneous catheter19 deaths366 reports
- THERMOCOOL SMARTTOUCH SF D134701Biosense Webster Inc · Cardiac ablation percutaneous catheter11 deaths278 reports
- ThermoCool SmartTouch D133602Biosense Webster Inc · Cardiac ablation percutaneous catheter8 deaths225 reports
- SMARTABLATE SAT001Biosense Webster Inc · Cardiac ablation percutaneous catheter185 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page