Guider Softip™ XF H965100480Recalls & reported problems

Boston Scientific Corporation · Guide Catheter · Class 2

All models of Guider Softip XF (17)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
1

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08714729202523), received between Dec 10, 2019 and Dec 15, 2023 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Fracture” (2 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Jul 27, 2023Class IIOpen, Classified

    Stryker Neurovascular has observed that certain lots of Guider Softip XF Guide Catheters appear to have the incorrect tip curve shape. The impacted products were distributed with a tip curve shape which differs from the labeled tip curve shape.

    Z-0014-2024 · Root cause: Employee error · Recall details · FDA record ↗

Most reported problems

Device problems

  • Fracture2
  • Peeled/Delaminated1

Patient problems

  • Foreign Body In Patient1
  • Muscle Weakness/Atrophy1
  • No Clinical Signs, Symptoms or Conditions1
  • No Known Impact Or Consequence To Patient1
  • Paralysis1
  • Stroke/CVA1
  • Syncope/Fainting1
  • Thrombosis/Thrombus1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 15, 2023Fracture; Fracture

    IT WAS REPORTED THAT PATIENT WITH STROKE WAS TREATED SUCCESSFULLY. HOWEVER, THE NEXT DAY PATIENT HAD SECOND STROKE AND HAD TO BE RETREATED. PHYSICIAN PERFORMED THROMBECTOMY PROCEDURE TO REMOVE THE CLOT. DURING THE PROCEDURE THE OPERATOR FOUND THE RADIOPAQUE MARKER OF THE SUBJECT GUIDE CATHETER IN THE M1 SEGMENT FROM THE FIRST PROCEDURE. ATTEMPTS WERE MADE TO REMOVE THE MARKER BUT WERE UNSUCCESSFUL AND WAS LEFT INSIDE THE PATIENT¿S ANATOMY. THERE WAS SURGICAL DELAY REPORTED DURING THE PROCEDURE.

    Patient problems: Foreign Body In Patient; Muscle Weakness/Atrophy; Paralysis; Stroke/CVA; Syncope/Fainting; Thrombosis/Thrombus

    MAUDE report 18334427 ↗
  • MalfunctionMay 23, 2022Peeled/Delaminated; Peeled/Delaminated

    THE DEVICE WAS RETURNED FOR ANALYSIS AND THE INVESTIGATION OF THE DEVICE REVEALED THAT THE CATHETER (SUBJECT DEVICE) PTFE COATING WAS PEELING. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14468940 ↗
  • InjuryDec 10, 2019Fracture; Fracture

    IT WAS REPORTED THAT DURING PROCEDURE, THE GUIDE CATHETER (SUBJECT DEVICE) DISTAL RADIOPAQUE MARKER CAME OFF DURING EMBOLIZATION OF A DURAL FISTULA. THE OPERATOR CHANGED THE INITIAL SHEATH TO A 12F SHEATH AND EXCHANGED THE GUIDEWIRE. THEN THE OPERATOR INFLATED A 8 X 4 BALLOON INSIDE THE TIP RING THAT BROKE OFF AND MANAGED TO RETRIEVE THE TIP FROM THE PATIENT. THIS WAS POSSIBLE AS THE WIRE KEPT THE RADIOPAQUE TIP CONSTRAINED INSIDE THE PATIENT. THERE WAS 1 HOUR SURGICAL DELAY. THERE WERE NO CLINICAL CONSEQUENCES TO THE PATIENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9448359 ↗

Other CATHETER, PERCUTANEOUS devices

All CATHETER, PERCUTANEOUS devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page