Renegade™ M001182520Recalls & reported problems
Boston Scientific Corporation · Fiber Braided Microcatheter · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08714729235125), received between Mar 24, 2021 and Apr 29, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Material Integrity Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Material Integrity Problem2
- Break1
- Difficult to Insert1
- Material Deformation1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 29, 2025Material Deformation; Material Integrity Problem; Material Deformation; Material Integrity Problem
IT WAS REPORTED THAT COATING ISSUE OCCURRED. A 130/20/1TIP RENEGADE MICROCATHETER WAS SELECTED FOR USE IN THE LIVER FOR A TRANSCATHETER ARTERIAL CHEMOEMBOLIZATION (TACE) PROCEDURE. WHEN THE DEVICE WAS WITHDRAWN, IT WAS NOTED THAT THE COATING FELT A LITTLE BIT WRONG. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT. IT WAS FURTHER REPORTED THAT DURING PREPARATION. A KINK WAS OBSERVED ON THE DEVICE. WHEN REMOVED, THERE WAS A PEELING SECTION OF THE COATING ON THE DEVICE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21928575 ↗MalfunctionSep 25, 2023Break; Break
IT WAS REPORTED THAT BROKEN CATHETER OCCURRED. A 130/20 RENEGADE CATHETER-INFUSION WAS SELECTED FOR USE. DURING PREPARATION, IT WAS NOTED THAT 1CM FROM THE DISTAL PART OF THE CATHETER GOT BROKEN. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. NO COMPLICATIONS WERE REPORTED, AND THE PATIENT WAS STABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17809418 ↗MalfunctionMar 24, 2021Difficult to Insert; Material Integrity Problem; Difficult to Insert; Material Integrity Problem
IT WAS REPORTED THAT THE COATING PEELED OFF. THE TARGET LESION WAS LOCATED IN THE LIVER AREA. A RENEGADE WAS SELECTED FOR USE. DURING PROCEDURE, AFTER THE FIRST SESSION CHEMO DRUG INJECTION IN A LESION ANOTHER ARTERY SELECTION WAS PERFORMED. HOWEVER, THE DEVICE COULD NOT BE PUSHED AS THE POSITION OF THE RENEGADE IS JUST IN THE TIP OF THE RH CATHETER WHEN OBSERVED UNDER ANGIOGRAM BUT IT CAN'T BE PUSH OVER. BOTH CATHETER AND GUIDEWIRE WERE THEN REMOVED DIRECTLY FROM THE PATIENT'S BODY WITHOUT ANY FRICTION NOTED. UPON INSPECTION, THE CATHETER WAS ASTRINGENT TO TOUCH AS THE SURFACE WAS NOT SMOOTH, THUS IT WAS PRESUMED THAT THE HYDROPHILIC COATING OF RENEGADE CATHETER MIGHT BE PEELED OFF DURING THE OPERATION. THE PROCEDURE WAS COMPLETED WITH A DIFFERENT DEVICE. NO COMPLICATIONS REPORTED AND PATIENT IS STABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11561068 ↗
Other Catheter, continuous flush devices
- PROWLER SELECT 606-S255XMedos International Sàrl · Catheter, continuous flush2 deaths980 reports
- PhenomTM 27 Catheter FG15150-0615-1SMicro Therapeutics, Inc. · Catheter, continuous flush2 deaths139 reports
- MarathonTM 105-5056Micro Therapeutics, Inc. · Catheter, continuous flush124 reports
- MarksmanTM FA-55150-1030Micro Therapeutics, Inc. · Catheter, continuous flush109 reports
- Renegade™ HI-FLO™ Kit M001183020Boston Scientific Corporation · Catheter, continuous flush109 reports
- EkoSonic® 6779-002Boston Scientific Corporation · Catheter, Continuous Flush1 recall4 deaths56 reports
- Chameleon CH08-40-75USMozarc Medical US LLC · Catheter, continuous flush2 recalls4 reports
- RebarTM 105-5081-153Micro Therapeutics, Inc. · Catheter, continuous flush2 deaths102 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.