Renegade™ HI-FLO™ M001182850Recalls & reported problems
Boston Scientific Corporation · Microcatheter · Class 2
All models of Renegade HI-FLO (7)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 08714729280606), received between Sep 13, 2019 and May 9, 2023 — classified as 1 injury, 3 malfunctions.
The most frequently reported specific device problem is “Physical Resistance/Sticking” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Physical Resistance/Sticking2
- Detachment of Device or Device Component1
- Difficult to Open or Remove Packaging Material1
- Entrapment of Device1
- Material Deformation1
- Material Integrity Problem1
- Stretched1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Consequences Or Impact To Patient1
- No Patient Involvement1
- Thrombosis/Thrombus1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryMay 9, 2023Physical Resistance/Sticking; Physical Resistance/Sticking
IT WAS REPORTED THAT A THROMBUS WAS NOTICED. A RENEGADE HI-FLO WAS SELECTED FOR USE IN A MODERATE TO MILDLY TORTUOUS VESSEL. DURING THE PROCEDURE, IT WAS NOTED THAT THE DEVICE DID NOT MOVE SMOOTHLY. WHEN IT WAS USED FOR GASTRO-RENAL SHUNT, IT DID NOT SLIDE WELL AND COULD NOT BE PLACED. THE THROMBUS MIGHT BE CLOGGED INSIDE. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED.
Patient problems: Thrombosis/Thrombus
MAUDE report 16899397 ↗MalfunctionSep 16, 2021Entrapment of Device; Detachment of Device or Device Component; Entrapment of Device; Detachment of Device or Device Component
IT WAS REPORTED THAT THE DEVICE GOT SEPARATED WHEN TAKEN OUT. THE 50% STENOSED TARGET LESION WAS LOCATED IN THE MILDLY TORTUOUS AND NONE CALCIFIED RENAL ARTERY. A 105/20 RENEGADE HI-FLO WAS SELECTED FOR USE. DURING PREPARATION, THE BOX WAS OPENED AND THE DEVICE WAS ATTEMPTED TO BE PULLED OUT BY OPENING THE VINYL. IT WAS NOTED THAT IT FELT LIKE THE LOOP (PROTECTIVE TUBE) AND THE DEVICE WERE ADHERED TO EACH OTHER. THE DEVICE ULTIMATELY SEPARATED WHEN TAKEN OUT OF THE PACKAGE AND WAS NOT USED. THE PROCEDURE WAS SUCCESSFULLY COMPLETED USING ANOTHER OF THE SAME DEVICE. THERE WAS NO EFFECT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12485839 ↗MalfunctionJan 26, 2021Stretched; Material Deformation; Physical Resistance/Sticking; Stretched; Material Deformation; Physical Resistance/Sticking
IT WAS REPORTED THAT THERE WAS A MILD RESISTANCE WHEN THE DEVICE WAS PULLED OUT. A 105/20 RENEGADE HI-FLO WAS SELECTED FOR USE. THE NON-STENOSED TARGET LESION WAS MODERATELY TORTUOUS AND NON-CALCIFIED. DURING REMOVAL OF THE DEVICE FROM THE PATIENT'S BODY, IT WAS NOTED THAT THERE WAS A MILD RESISTANCE WHEN THE DEVICE WAS PULLED OUT. UPON CHECKING ON THE DEVICE, IT WAS OBSERVED THAT THE TIP WAS STRETCHED AND DEFORMED. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF SAME DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED. IT WAS FURTHER REPORTED THAT THE TARGET LESION WAS IN THE HEPATIC ARTERY. THE MICROCATHETER WAS DELIVERED MULTIPLE TIMES. THE MICROCATHETER AND OTHER DEVICES WERE SUFFICIENTLY FLUSHED AND HYDRATED THROUGHOUT THE PROCEDURE. THE DEVICE WAS REMOVED FROM THE PATIENT'S BODY WITHOUT ANY PROBLEM.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Consequences Or Impact To Patient
MAUDE report 11232592 ↗MalfunctionSep 13, 2019Difficult to Open or Remove Packaging Material; Material Integrity Problem; Difficult to Open or Remove Packaging Material; Material Integrity Problem
REPORTABLE ON ANALYSIS COMPLETED ON 23AUGUST2019. IT WAS REPORTED THAT REMOVAL DIFFICULTIES FROM THE CARRIER TUBE OCCURRED. DURING PREPARATION OF A 105/20 RENEGADE HI-FLO CATHETER, THE CATHETER WAS DIFFICULT TO REMOVE FROM THE CARRIER TUBE. THE CARRIER TUBE WAS FLUSHED AGAIN AND ATTEMPTS TO REMOVE THE CATHETER RESULTED IN STRETCHING THE CATHETER WHEN IT WAS FINALLY RELEASED FROM THE CARRIER TUBE. HOWEVER RETURNED ANALYSIS REVEALED A DETACHED SHAFT.
Patient problems: No Patient Involvement
MAUDE report 9035803 ↗
FDA clearance and classification
The FDA regulates product code KRA (catheter, continuous flush) under 21 CFR 870.1210 as a Class II device. 21 CFR 870.1210 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Renegade™ HI-FLO™ M001182850
Has the Renegade™ HI-FLO™ M001182850 been recalled?
No FDA recall record in our data names this exact device identifier (DI 08714729280606), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Renegade™ HI-FLO™ M001182850?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Sep 13, 2019 and May 9, 2023. In those reports, the most common specific device problems are “Physical Resistance/Sticking” (2), “Detachment of Device or Device Component” (1) and “Difficult to Open or Remove Packaging Material” (1); the most common patient problem is “Thrombosis/Thrombus” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Renegade™ HI-FLO™ M001182850?
None of the reports are classified as deaths, 1 as an injury and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Renegade™ HI-FLO™ M001182850, and is it still sold?
The FDA's device database lists Boston Scientific Corporation as the company responsible for it (brand Renegade™ HI-FLO™, model M001182850). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Catheter, continuous flush devices
- PROWLER SELECT 606-S255XMedos International Sàrl · Catheter, continuous flush2 deaths973 reports
- PhenomTM 27 Catheter FG15150-0615-1SMicro Therapeutics, Inc. · Catheter, continuous flush2 deaths139 reports
- MarathonTM 105-5056Micro Therapeutics, Inc. · Catheter, continuous flush124 reports
- Renegade™ HI-FLO™ Kit M001183020Boston Scientific Corporation · Catheter, continuous flush109 reports
- MarksmanTM FA-55150-1030Micro Therapeutics, Inc. · Catheter, continuous flush109 reports
- EkoSonic® 6779-002Boston Scientific Corporation · Catheter, Continuous Flush1 recall4 deaths55 reports
- Chameleon CH08-40-75USMozarc Medical US LLC · Catheter, continuous flush2 recalls4 reports
- RebarTM 105-5081-153Micro Therapeutics, Inc. · Catheter, continuous flush2 deaths102 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page