Renegade™ HI-FLO™ M001182910Recalls & reported problems
Boston Scientific Corporation · Microcatheter · Class 2
All models of Renegade HI-FLO (7)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08714729280668), received between Dec 14, 2022 and Feb 26, 2026 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Device Contamination with Chemical or Other Material1
- Difficult to Advance1
- Difficult to Remove1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 26, 2026Difficult to Remove; Difficult to Advance
IT WAS REPORTED THAT DEVICE REMOVAL DIFFICULTY OCCURRED. THE TARGET LESION WAS LOCATED IN THE VESSEL IN THE LIVER. A 150/20 RENEGADE HI FLO AND A .014/190CM GW TRANSEND PERIPH WAS SELECTED FOR USE. DURING THE PROCEDURE, THE RENEGADE AND TRANSCEND DEVICES WERE UNABLE TO ADVANCE THROUGH A 5F GUIDE CATHETER AT THE PROXIMAL END, JUST BEYOND THE HUB. A NEW GUIDE WAS ATTEMPTED, BUT THE SAME ISSUE OCCURRED WITH THE FIRST RENEGADE AND TRANSCEND. NEW RENEGADE AND TRANSCEND DEVICES WERE THEN OPENED AND ADVANCES TO THE TIP OF THE 5F GUIDE, THE RENEGADE WOULD NOT ADVANCE OUT THE TIP OF THE GUIDE. IT WAS NOTED THAT THERE WERE GRITTINESS AND FRICTION DURING INSERTION AND REMOVAL. THE PROCEDURE WAS COMPLETED WITH A NON-BOSTON DEVICE. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24456304 ↗MalfunctionSep 26, 2023Break; Break
IT WAS REPORTED THAT THE CATHETER WAS BROKEN. A RENEGADE HI-FLO CATHETER WAS SELECTED FOR USE IN AN EMBOLIZATION PROCEDURE. WHILE OPENING THE DEVICE PACKAGE AND REMOVING THE DEVICE, THE CATHETER BROKE. ANOTHER RENEGADE HI-FLO CATHETER WAS SELECTED FOR USE. THE PROCEDURE WAS COMPLETED. THERE WERE NO PATIENT CONSEQUENCES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17819858 ↗MalfunctionDec 14, 2022Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material
IT WAS REPORTED THAT A CONTAMINATION OCCURRED. THE TARGET LESION WAS LOCATED IN THE MODERATELY TORTUOUS VESSEL. A RENEGADE HI-FLO WAS SELECTED FOR USE. DURING THE PROCEDURE, WHEN THE DEVICE WAS REMOVED FROM THE WRAPPER, IT WAS NOTED THAT A SMALL FOREIGN OBJECT WAS FOUND IN THE HUB PART. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15983642 ↗
FDA clearance and classification
The FDA regulates product code KRA (catheter, continuous flush) under 21 CFR 870.1210 as a Class II device. 21 CFR 870.1210 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Renegade™ HI-FLO™ M001182910
Has the Renegade™ HI-FLO™ M001182910 been recalled?
No FDA recall record in our data names this exact device identifier (DI 08714729280668), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Renegade™ HI-FLO™ M001182910?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Dec 14, 2022 and Feb 26, 2026. In those reports, the most common specific device problems are “Break” (1), “Device Contamination with Chemical or Other Material” (1) and “Difficult to Advance” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Renegade™ HI-FLO™ M001182910?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Renegade™ HI-FLO™ M001182910, and is it still sold?
The FDA's device database lists Boston Scientific Corporation as the company responsible for it (brand Renegade™ HI-FLO™, model M001182910). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Catheter, continuous flush devices
- PROWLER SELECT 606-S255XMedos International Sàrl · Catheter, continuous flush2 deaths973 reports
- PhenomTM 27 Catheter FG15150-0615-1SMicro Therapeutics, Inc. · Catheter, continuous flush2 deaths139 reports
- MarathonTM 105-5056Micro Therapeutics, Inc. · Catheter, continuous flush124 reports
- Renegade™ HI-FLO™ Kit M001183020Boston Scientific Corporation · Catheter, continuous flush109 reports
- MarksmanTM FA-55150-1030Micro Therapeutics, Inc. · Catheter, continuous flush109 reports
- EkoSonic® 6779-002Boston Scientific Corporation · Catheter, Continuous Flush1 recall4 deaths55 reports
- Chameleon CH08-40-75USMozarc Medical US LLC · Catheter, continuous flush2 recalls4 reports
- RebarTM 105-5081-153Micro Therapeutics, Inc. · Catheter, continuous flush2 deaths102 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page