Mach1™ H74934356520Recalls & reported problems
Boston Scientific Corporation · Guide Catheter · Class 2
All models of Mach1 (28)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08714729350781), received between Aug 7, 2019 and Aug 7, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Detachment of Device or Device Component1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 7, 2019Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT TIP DETACHMENT OCCURRED. THE 90% STENOSED TARGET LESION WAS LOCATED IN A MILDLY TORTUOUS AND SEVERELY CALCIFIED LEFT MAIN ARTERY. A MACH1 GUIDING CATHETER WAS SELECTED FOR USE IN A PERCUTANEOUS CORONARY INTERVENTION PROCEDURE. A STENT WAS PLACED FOLLOWED BY BALLOONING. THE BALLOON EXPANDED AFTER SLIGHTLY ENTERING INTO THE GUIDING CATHETER. IT WAS NOTED THAT THE TIP OF THE GUIDING CATHETER GOT SEPARATED, AND IT FLOWED INTO THE DIRECTION OF THE LEFT CIRCUMFLEX ARTERY. FLUOROSCOPY WAS PERFORMED AND IT WAS CONFIRMED THAT THE TIP DETACHED. THE PHYSICIAN TRIED TO RETRIEVE THE TIP WITH A BALLOON CATHETER, BUT IT COULD NOT BE RETRIEVED. IT WAS SUCCESSFULLY REMOVED WITH GOOSE NECK SNARE. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF SAME DEVICE. NO COMPLICATIONS WERE REPORTED. IT WAS FURTHER REPORTED THAT THE BALLOON CATHETER USED IN THE PROCEDURE WAS A NON-BSC BALLOON CATHETER AND THE PATIENT'S CURRENT CONDITION IS GOOD.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8869893 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page