Carotid WALLSTENT® M001719040Recalls & reported problems

Boston Scientific Corporation · Closed Cell Self-Expanding Stent · Class 3 · Implant

All models of Carotid WALLSTENT (7)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 08714729781103), received between Jul 10, 2017 and Aug 5, 2026 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Activation, Positioning or Separation Problem” (2 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Jul 7, 2025Class IOpen, Classified

    Certain batches are being removed due to an increase in complaints received in which physicians encountered greater than anticipated resistance while attempting to withdraw the stent delivery system (SDS) from the guidewire or embolic protection device (EPD) after successful stent deployment. The most serious potential adverse health consequence is stroke. Other risks include delay to procedure, vessel injury, vessel spasm, or stent disruption/damage necessitating additional intervention.

    Z-2273-2025 · Root cause: Process change control · Recall details · FDA record ↗

Most reported problems

Device problems

  • Activation, Positioning or Separation Problem2
  • Break1
  • Component Missing1
  • Device Damaged Prior to Use1
  • Material Deformation1
  • Mechanical Problem1
  • Positioning Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Patient Involvement1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 5, 2026Mechanical Problem; Activation, Positioning or Separation Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50141454 ↗
  • MalfunctionApr 22, 2025Break; Activation, Positioning or Separation Problem; Break; Activation, Positioning or Separation Problem

    IT WAS REPORTED THAT SHAFT BREAK OCCURRED. THE 95% STENOSED TARGET LESION WAS LOCATED IN THE NON-TORTUOUS AND NON-CALCIFIED CAROTID ARTERY. A 10X24,5.9F,135CM CAROTID WALLSTENT SELF-EXPANDING WAS SELECTED FOR USE. DURING DEPLOYMENT OF ABOUT 3/4 OF THE STENT, IT WAS NOTED THAT THE SHAFT BROKE AND PARTIALLY SEPARATED. EVENTUALLY, THE STENT WAS ABLE TO BE FULLY DEPLOYED AND THE WHOLE DELIVERY CATHETER WAS ABLE TO BE PULLED OUT. THE STENT WAS IMPLANTED AND WAS NOT RE-CONSTRAIN. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21886746 ↗
  • MalfunctionDec 16, 2021Positioning Failure; Material Deformation; Positioning Failure; Material Deformation

    IT WAS REPORTED THE STENT WAS BENT. A CAROTID WALLSTENT WAS SELECTED FOR USE IN A CORONARY ARTERY STENTING PROCEDURE. DURING THE PROCEDURE, AFTER THE STENT PASSED THE LESION, THE STENT WAS NOT ABLE DEPLOY. THE STENT TIP WAS FOUND TO BE BENT AND WAS REMOVED. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH A DIFFERENT DEVICE. THERE WERE NO PATIENT COMPLICATIONS AND THE PATIENT IS FINE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13019237 ↗
  • MalfunctionJul 10, 2017Device Damaged Prior to Use; Component Missing; Device Damaged Prior to Use; Component Missing

    IT WAS REPORTED THAT THE STENT WAS MISSING. DURING PREPARATION OF A 10X24,5.9F,135CM CAROTID WALLSTENT STENT, WHEN PHYSICIAN FLUSHED THE DEVICE, IT WAS NOTED THAT THERE WAS NO STENT ON THE DEVICE. THE DEVICE WAS NOT USED INSIDE THE PATIENT AND THE PROCEDURE WAS COMPLETED WITH A DIFFERENT DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: No Patient Involvement

    MAUDE report 6697280 ↗