NC Quantum Apex™ H7493912412400Recalls & reported problems
Boston Scientific Corporation · PTCA Dilatation Catheter · Class 2
All models of NC Quantum Apex (48)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 08714729783305), received between Jan 10, 2017 and Apr 11, 2023 — classified as 1 injury, 4 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
- Contamination1
- Detachment of Device or Device Component1
- Entrapment of Device1
- Failure to Advance1
- Material Rupture1
Patient problems
- No Consequences Or Impact To Patient2
- No Clinical Signs, Symptoms or Conditions1
- No Code Available1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 11, 2023Contamination; Contamination
IT WAS REPORTED THAT DEVICE CONTAMINATION OCCURRED. A 12MM X 4.00MM NC QUANTUM APEX WAS SELECTED FOR USE IN A PERCUTANEOUS CORONARY INTERVENTION OF THE TARGET LESION LOCATED IN THE LEFT MAIN ARTERY. HOWEVER, UPON OPENING THE PACKAGE, THERE WAS NO STERILE POUCH IN THE BOX AND THE BALLOON HOOP AND INFLATION CARD WERE JUST SITTING IN THE BOX. THE DEVICE WAS NOT USED DURING THE PROCEDURE SINCE IT WAS CONSIDERED UNSTERILE. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16714448 ↗InjuryOct 8, 2019Break; Material Rupture; Break; Material Rupture
IT WAS REPORTED THAT BALLOON RUPTURE AND DEVICE FRACTURE OCCURRED. A 12 MM X 4.00 MM NC QUANTUM APEX BALLOON CATHETER WAS ADVANCED FOR DILATATION OF A CALCIFIED LESION. DURING INFLATION, THE BALLOON RUPTURED AND WHEN THE DEVICE WAS BEING REMOVED, IT FRACTURED. ANOTHER BALLOON WAS PINNED IN THE GUIDE TO PULL OUT THE FRACTURED BALLOON AND COMPLETE THE PROCEDURE.
Patient problems: No Code Available
MAUDE report 9170089 ↗MalfunctionJan 30, 2019Failure to Advance; Failure to Advance
REPORTABLE BASED ON DEVICE ANALYSIS COMPLETED ON 11-JAN-2019. IT WAS REPORTED THAT CROSSING DIFFICULTIES WERE ENCOUNTERED. VASCULAR ACCESS WAS OBTAINED VIA THE FEMORAL ARTERY. THE 12X4.0MM TARGET LESION WAS LOCATED IN THE MODERATELY TORTUOUS AND MILDLY CALCIFIED RIGHT CORONARY ARTERY. A 12MM X 4.00MM NC QUANTUM APEX BALLOON CATHETER WAS ADVANCED BUT FAILED TO CROSS THE LESION DUE TO TORTUOSITY. THE PROCEDURE WAS COMPLETED WITH A DIFFERENT DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED AND THE PATIENT'S STATUS WAS STABLE. HOWEVER, RETURNED DEVICE ANALYSIS REVEALED HYPOTUBE SEPARATION.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8290200 ↗MalfunctionDec 19, 2018Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT BALLOON DETACHMENT OCCURRED. A 12MM X 4.00MM NC QUANTUM APEX BALLOON CATHETER WAS SELECTED FOR USED TO DILATE THE LESION; HOWEVER, IT WAS NOTED THAT THE BALLOON RIPPED OFF. NO PATIENT COMPLICATIONS WERE REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8182292 ↗MalfunctionJan 10, 2017Entrapment of Device; Entrapment of Device
IT WAS REPORTED THAT DURING A PERCUTANEOUS CATHETER INTERVENTION PROCEDURE, CATHETER ENTRAPMENT OCCURRED. THE TARGET LESION WAS LOCATED IN THE RAMUS INTERMEDIUS. A 4.00X12MM NC QUANTUM APEX MR BALLOON CATHETER WAS ADVANCED TO THE LESION. AFTER DILATION WITH 22 BAR, THE BALLOON CATHETER WAS REMOVED, BUT IT ENTRAPPED ON THE GUIDEWIRE. BOTH DEVICES WERE REMOVED TOGETHER. THE PROCEDURE WAS COMPLETED WITH THIS DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED AND THE PATIENT'S STATUS WAS WELL.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6239510 ↗
Other Catheters, transluminal coronary angioplasty, percutaneous devices
- MINI TREK™ 1012270-15Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous223 reports
- Maverick²™ H7493892815200Boston Scientific Corporation · Catheters, transluminal coronary angioplasty, percutaneous1 death203 reports
- MINI TREK™ 1012270-12Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous162 reports
- Maverick²™ H7493892820200Boston Scientific Corporation · Catheters, transluminal coronary angioplasty, percutaneous161 reports
- NC TREK 1012454-08Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous2 recalls59 reports
- TREK™ 1012272-15Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous2 deaths158 reports
- NC TREK 1012453-12Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous1 recall84 reports
- NC TREK 1012453-15Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous1 recall1 death83 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page