Epic™ Vascular H74939200081020Recalls & reported problems

Boston Scientific Corporation · Self-Expanding Stent System · Class 3

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
1
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 08714729805564), received between Dec 16, 2016 and Jan 22, 2025 — classified as 1 death, 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Activation, Positioning or Separation Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Activation, Positioning or Separation Problem1
  • Difficult to Remove1
  • Entrapment of Device1
  • Failure to Advance1
  • Fracture1
  • Material Deformation1
  • Mechanical Jam1

Patient problems

  • No Consequences Or Impact To Patient2
  • Cardiac Arrest1
  • Foreign Body In Patient1
  • Low Blood Pressure/ Hypotension1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 22, 2025Difficult to Remove; Failure to Advance; Material Deformation; Difficult to Remove; Failure to Advance; Material Deformation

    IT WAS REPORTED THAT THE PATIENT EXPERIENCED CARDIAC ARREST AND HYPOTENSION REQUIRING ADDITIONAL INTERVENTION. THE PATIENT UNDERWENT ENDOVASCULAR REPAIR UNDER LOCAL ANESTHESIA. THE 60% STENOSED AND OCCLUDED TARGET LESION WAS LOCATED IN THE MODERATELY TORTUOUS AND MILDLY CALCIFIED COMMON ILIAC ARTERY, EXTERNAL ILIAC ARTERY, AND MID TO DISTAL END SUPERFICIAL FEMORAL ARTERY. AFTER GAINING VASCULAR ACCESS WITH A 5F FEMORAL ARTERY PUNCTURE SHEATH, A V-18 GUIDEWIRE WAS ADVANCED FOLLOWED BY PLACING A 6F 45CM SHEATH. PREDILATATION WAS PERFORMED USING AN 8X80 MUSTANG BALLOON FOLLOWED BY ADVANCING AN 8X100X120 EPIC VASCULAR SELF-EXPANDING STENT; HOWEVER, RESISTANCE WAS FELT DURING INTRODUCTION AND THE STENT COULD NOT REACH THE LESION SITE. DURING WITHDRAWAL, SIGNIFICANT RESISTANCE WAS NOTED AND THE PHYSICIAN APPLIED SIGNIFICANT FORCE. AFTER REMOVAL, IT WAS NOTED THAT THE STENT DELIVERY SHAFT AND THE MIDDLE SECTION OF THE STENT WAS KINKED WHICH LED TO CROSSING FAILURE. THE PATIENT IS OLDER AND HAD SUFFERED MULTIPLE UNDERLYING DISEASES, AND AT THIS POINT, THE PATIENT HAD A CARDIAC ARREST DUE TO DROP IN BLOOD PRESSURE. THE PHYSICIAN CARRIED OUT A SERIES OF FIRST-AID COMPRESSIONS. THE PATIENT'S

    Patient problems: Cardiac Arrest; Low Blood Pressure/ Hypotension

    MAUDE report 21211603 ↗
  • DeathFeb 3, 2022Fracture; Fracture

    IT WAS REPORTED THAT STENT FRACTURE OCCURRED. ON (B)(6) 2021, THE PATIENT PRESENTED DUE TO UPPER GASTROINTESTINAL BLEEDING AND TIPS (TRANS INTRAHEPATIC PORTAL SHUNT) WAS PERFORMED, AND THE PROCEDURE WAS SUCCESSFUL. ON (B)(6) 2022, COMPUTED TOMOGRAPHY REVEALED THAT THE STENT WAS FRACTURED. AT THE TIME OF THE REPORT, THERE WERE NO OBVIOUS SYMPTOMS.

    Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions

    MAUDE report 13446080 ↗
  • MalfunctionMar 8, 2019Activation, Positioning or Separation Problem; Mechanical Jam; Activation, Positioning or Separation Problem; Mechanical Jam

    IT WAS REPORTED THAT THE STENT PARTIALLY DEPLOYED. AN EPIC VASCULAR STENT WAS SELECTED FOR USE FOR A BALLOON DILATION AND PERCUTANEOUS INTERVENTIONAL PROCEDURE OF THE ILIAC ARTERY IN THE RIGHT LOWER EXTREMITY TO TREAT ARTERIAL STENOSIS. THE PHYSICIAN ATTEMPTED TO DEPLOY THE STENT IN THE LESION USING THE THUMBWHEEL, HOWEVER, THE THUMBWHEEL COULD NO LONGER BE USED AFTER THE TOP OF THE STENT WAS DEPLOYED. THE PHYSICIAN THEN WITHDREW THE ENTIRE STENT DELIVERY SYSTEM COMPLETELY. THERE WERE NO PATIENT COMPLICATIONS REPORTED. IT WAS FURTHER REPORTED THAT THE STENT WAS DEPLOYED A LITTLE, AND THE STENT WAS NOT FULLY APPOSED TO THE VESSEL WALLS. THERE WAS NO STENT DAMAGE. THE PROCEDURE WAS COMPLETED WITH A DIFFERENT DEVICE.NO PATIENT COMPLICATIONS WERE REPORTED AND THE PATIENT'S STATUS WAS STABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8403495 ↗
  • MalfunctionDec 16, 2016Entrapment of Device; Entrapment of Device

    IT WAS REPORTED THAT CATHETER ENTRAPMENT OCCURRED. THE TARGET LESION WAS LOCATED IN THE SUPERFICIAL FEMORAL ARTERY. A 8X100X120 EPIC¿ VASCULAR STENT WAS BEING DEPLOYED, HOWEVER, THE STENT WAS DIFFICULT TO DEPLOY AND GOT STUCK HALFWAY THROUGH DEPLOYING IT. THE PHYSICIAN WAS ABLE TO FULLY DEPLOY THE STENT. UPON WITHDRAWING THE CATHETER, IT WAS NOTED THE INNER PART OF THE WHITE TUBING GOT STUCK ON THE GUIDEWIRE. THE CATHETER AND GUIDEWIRE WERE REMOVED TOGETHER FROM THE PATIENT. BECAUSE WIRE ACCESS WAS LOST, THE CASE WAS ENDED PREMATURELY WITHOUT POST DILATING THE IMPLANTED STENT. THERE WERE NO PATIENT COMPLICATIONS AND THE PATIENT STATUS WAS OKAY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6180824 ↗

Other STENT, ILIAC devices

All STENT, ILIAC devices →