Epic™ Vascular H74939200091070Recalls & reported problems

Boston Scientific Corporation · Self-Expanding Stent System · Class 3

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08714729805892), received between Jun 28, 2018 and Dec 22, 2023 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Bent” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Bent1
  • Difficult to Remove1
  • Entrapment of Device1
  • Failure to Advance1
  • Material Deformation1
  • Migration or Expulsion of Device1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 22, 2023Entrapment of Device; Difficult to Remove; Entrapment of Device; Difficult to Remove

    IT WAS REPORTED THAT DIFFICULTY IN REMOVING FROM GUIDEWIRE OCCURRED. THE 100% STENOSED TARGET LESION WAS LOCATED IN SEVERELY TORTUOUS AND SEVERELY CALCIFIED COMMON ILIAC ARTERY. AFTER CROSSING THE LESION WITH A NON-BSC GUIDEWIRE, A 9 X 100 X 75 EPIC STENT WAS ADVANCED AND SUCCESSFULLY DEPLOYED. AN ATTEMPT TO WITHDRAW THE DELIVERY SYSTEM WAS MADE, BUT IT WAS DIFFICULT TO REMOVE AND WAS STUCK TOGETHER WITH THE NON-BSC GUIDEWIRE. BOTH DEVICES WERE REMOVED AND THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS NOR INJURIES REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18383876 ↗
  • MalfunctionNov 18, 2021Failure to Advance; Material Deformation; Failure to Advance; Material Deformation

    REPORTABLE BASED ON DEVICE ANALYSIS COMPLETED ON 09-NOV-2021. IT WAS REPORTED THAT CROSSING DIFFICULTIES AND KINK OCCURRED. VASCULAR ACCESS WAS OBTAINED VIA CONTRALATERAL APPROACH. THE 95% STENOSED TARGET LESION WAS LOCATED IN THE SEVERELY TORTUOUS AND MODERATELY CALCIFIED EXTERNAL ILIAC ARTERY. FOLLOWING A 6F INTRODUCER SHEATH WAS PLACED, A .035 NON-BSC GUIDEWIRE WAS CROSSED THE LESION. PRE-DILATION WAS PERFORMED RESULTING TO A 60% RESIDUAL STENOSIS. A 9X100X75 EPIC VASCULAR STENT WAS ADVANCED FOR TREATMENT. HOWEVER, THE DEVICE UNABLE TO CROSS THE LESION AND KINK WAS NOTED. THE PROCEDURE WAS COMPLETED WITHOUT REPLACING THE DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED. HOWEVER, DEVICE ANALYSIS REVEALED STENT DEPLOYED OUTSIDE OF THE SHEATH.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12836349 ↗
  • InjuryJun 28, 2018Bent; Migration or Expulsion of Device; Bent; Migration or Expulsion of Device

    IT WAS REPORTED THAT STENT DAMAGE AND MIGRATION OCCURRED. THE 75% STENOSED TARGET LESION WAS LOCATED IN THE MILDLY TORTUOUS AND SEVERELY CALCIFIED ILIAC ARTERY. AFTER PRE-DILATION, A 9X100X75MM EPIC¿ VASCULAR STENT WAS IMPLANTED FOR TREATMENT. HOWEVER, WHEN PHYSICIAN TRIED TO ADVANCE THE SHEATH FURTHER WHILE USING DILATOR, IT WAS NOTED THAT THE EDGE OF THE STENT WAS CAUGHT IN THE GAP AND GOT FLATTENED. UPON PUSHING FURTHER, THE STENT SHIFTED. THE PROCEDURE WAS COMPLETED BY IMPLANTING ANOTHER STENT INSIDE THE EPIC STENT. NO PATIENT COMPLICATIONS NOR INJURIES WERE REPORTED. THE FLOW UNTIL THE DISTAL WAS ALSO GOOD.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7647823 ↗

Other STENT, ILIAC devices

All STENT, ILIAC devices →