Emerge™ H7493918908300Recalls & reported problems

Boston Scientific Corporation · PTCA Dilatation Catheter · Class 2

All models of Emerge (54)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 08714729806547), received between Sep 10, 2018 and Jan 5, 2024 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Break1
  • Failure to Deflate1
  • Material Rupture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1
  • No Consequences Or Impact To Patient1
  • No Known Impact Or Consequence To Patient1
  • No Patient Involvement1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 5, 2024Failure to Deflate; Failure to Deflate

    IT WAS REPORTED THAT BALLOON DEFLATION ISSUE OCCURRED. A 3.00MM X 8MM EMERGE BALLOON CATHETER WAS USED IN A PERCUTANEOUS CORONARY INTERVENTION; HOWEVER, DEFLATION ISSUE WAS NOTED. THE DEVICE WAS REPLACED, AND THE PROCEDURE WAS COMPLETED WITH NO PATIENT COMPLICATIONS NOR INJURIES REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18450062 ↗
  • MalfunctionOct 25, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REPORTABLE BASED ON DEVICE ANALYSIS COMPLETED ON 04OCT2018. THIS 3.00MM X 8MM EMERGE BALLOON CATHETER WAS RECEIVED WITH NO REPORTED ISSUES. HOWEVER, RETURNED DEVICE ANALYSIS REVEALED SEPARATED HYPOTUBE. DEVICE EVALUATED BY MANUFACTURER: THE RETURNED PRODUCT CONSISTED OF AN EMERGE BALLOON CATHETER. THE OUTER SHAFT, INNER SHAFT, BALLOON AND TIP WERE VISUALLY AND MICROSCOPICALLY EXAMINED. VISUAL EXAMINATION REVEALED MULTIPLE KINKS ALONG THE HYPOTUBE. THE HYPOTUBE IS SEPARATED 79.6CM FROM THE HUB. MICROSCOPIC EXAMINATION REVEALED THAT THE TIP IS DAMAGED AND THE BALLOON IS LOOSE. THERE IS BLOOD PRESENT IN THE HUB, INFLATION LUMEN, AND BALLOON. THE BROKEN SHAFT WAS CONNECTED TO A TUOHY ADAPTER AND STOPCOCK THEN INFLATED USING A BALLOON INFLATION DEVICE TO CHECK FOR POSSIBLE DAMAGES TO THE BALLOON. THE BALLOON WAS INFLATED TO RBP OF 14ATM AND COULD HOLD PRESSURE FOR 5 MINUTES BEFORE IT WAS DEFLATED. INSPECTION OF THE REMAINDER OF THE DEVICE PRESENTED NO OTHER DAMAGE OR IRREGULARITIES.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8005690 ↗
  • MalfunctionSep 25, 2018Break; Break

    IT WAS REPORTED THAT SHAFT BREAK OCCURRED. DURING PREPARATION OF THE DEVICE, THE PHYSICIAN TOOK THE BALLOON OUT OF THE LOOP IN THE HYPOTUBE. IT WAS NOTICED THAT THE SHAFT SEPARATED WHERE THE HYPOTUBE MEETS THE BALLOON. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE, NO PATIENT COMPLICATIONS NOR INJURIES WERE REPORTED.

    Patient problems: No Patient Involvement

    MAUDE report 7906161 ↗
  • MalfunctionSep 10, 2018Material Rupture; Material Rupture

    IT WAS REPORTED THAT BALLOON RUPTURE OCCURRED. THE TARGET LESION WAS LOCATED IN A HEAVILY CALCIFIED VESSEL. A 3.00MM X 8MM EMERGE BALLOON CATHETER WAS ADVANCED FOR DILATATION. HOWEVER, THE BALLOON MATERIAL WAS TORN IN THE PROCESS. NO PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7862427 ↗

Other Catheters, transluminal coronary angioplasty, percutaneous devices

All Catheters, transluminal coronary angioplasty, percutaneous devices →