Adverse event reports
1
Deaths reported
1
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08714729843856), received between Oct 23, 2020 and Oct 23, 2020 — classified as 1 death.

1 other recall cover devices cleared under the same FDA submission (P130030); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Death1
  • Low Blood Pressure/ Hypotension1
  • Stenosis1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • DeathOct 23, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT HYPOTENSION, VESSEL OCCLUSION OCCURRED AND PATIENT DIED. IT WAS REPORTED THAT HYPOTENSION, VESSEL OCCLUSION AND DEATH OCCURRED. THE PATIENT PRESENTED WITH GASTROINTESTINAL BLEEDING AND DEVELOPED ST-SEGMENT ELEVATION MYOCARDIAL INFARCTION. THE TARGET LESION LOCATED IN THE LEFT ANTERIOR DESCENDING ARTERY (LAD) WAS TREATED WITH 24 X 2.50, 20 X 3.00 AND 24 X 2.50 REBEL BARE METAL STENTS. POST PROCEDURE, THE PATIENT BECAME AGITATED WITH HYPOTENSION. THE PATIENT WENT INTO PULSELESS ELECTRICAL ACTIVITY, AND WAS CODED AND INTUBATED. A NON-BOSTON SCIENTIFIC TEMPORARY VENTRICULAR SUPPORT DEVICE WAS INSERTED. RE-CATHETERIZATION SHOWED TOTAL OCCLUSION IN THE LAD AND PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY WAS PERFORMED. THE PATIENT CONTINUED TO REQUIRE CARDIOPULMONARY RESUSCITATION AND MULTIPLE VASOPRESSOR IN THE INTENSIVE CARE UNIT. THE PATIENT SUBSEQUENTLY EXPIRED.

    Patient problems: Death; Low Blood Pressure/ Hypotension; Stenosis

    MAUDE report 10729634 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P130030. One submission often covers many models, so check the product and lot details in each record.

  • Z-0580-2020 · Oct 24, 2019 · Terminated
    Rebel Monorail PtCr Coronary Stent System, REF / Catalog No. H7493927324300, Rebel MR OUS 3.0mm x 24mm. The Rebel Monorail (MR) Stent System is a balloon expandable Platinum Chro

Other STENT, CORONARY devices

All STENT, CORONARY devices →