Captivator™ COLD M00561100Recalls & reported problems

Boston Scientific Corporation · Single-Use Snare · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Quick summary

This Boston Scientific Captivator snare has 371 reports, with no deaths and 37 injuries. Most describe the snare failing to cut polyps, and some describe the wire loop breaking or detaching, with a few mentioning bleeding. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
371
Deaths reported
0
Injuries reported
38
Recalls naming it
0

Summary

The FDA's MAUDE database contains 371 adverse event reports that list this exact device (DI 08714729971252), received between Nov 19, 2018 and Sep 18, 2026 — classified as 38 injuries, 333 malfunctions.

The most frequently reported specific device problem is “Failure to Cut” (258 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 5 reportsJan 2024: 4 reportsFeb 2024: 3 reportsMar 2024: 4 reportsApr 2024: 2 reportsMay 2024: 2 reportsJun 2024: 6 reportsJul 2024: 2 reportsAug 2024: 0 reportsSep 2024: 3 reportsOct 2024: 3 reportsNov 2024: 3 reportsDec 2024: 1 reportsJan 2025: 7 reportsFeb 2025: 11 reportsMar 2025: 9 reportsApr 2025: 5 reportsMay 2025: 20 reportsJun 2025: 10 reportsJul 2025: 8 reportsAug 2025: 27 reportsSep 2025: 7 reportsOct 2025: 19 reportsNov 2025: 30 reportsDec 2025: 20 reportsJan 2026: 15 reportsFeb 2026: 3 reportsMar 2026: 9 reportsApr 2026: 3 reportsMay 2026: 0 reportsJun 2026: 4 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reportsNov 2026: 0 reports20242025202630
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Cut258
  • Break50
  • Detachment of Device or Device Component38
  • Mechanical Problem31
  • Retraction Problem29
  • Difficult to Open or Close22
  • Adverse Event Without Identified Device or Use Problem17
  • Material Twisted/Bent14

Patient problems

  • No Clinical Signs, Symptoms or Conditions295
  • No Consequences Or Impact To Patient36
  • No Known Impact Or Consequence To Patient21
  • Hemorrhage/Blood Loss/Bleeding11
  • Unspecified Tissue Injury10
  • Exposure to Body Fluids3
  • Insufficient Information2
  • Anxiety1

Recent adverse event reports

The 25 most recent of 371 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 18, 2026Break

    It was reported to Boston Scientific Corporation that a Captivator Cold Snare was used in a polypectomy procedure performed on (b)(6)2026.\\During the procedure, the snare broke when the first cold polypectomy resection was done. The procedure was completed with another of the same device. \\There were no patient complications reported as a result of this event.\\No additional information has been received despite Good Faith Efforts.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50820518 ↗
  • MalfunctionJun 18, 2026Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A CAPTIVATOR COLD SNARE WAS USED IN THE COLON DURING A COLONOSCOPY WITH POLYPECTOMY PROCEDURE PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE METAL WIRE OF THE SNARE BECAME DETACHED FROM THE PLASTIC COMPONENT OF THE DEVICE, RESULTING IN IMMEDIATE LOSS OF FUNCTIONALITY AND INABILITY TO USE THE DEVICE AS INTENDED. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVE

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25545972 ↗
  • InjuryJun 16, 2026Entrapment of Device; Detachment of Device or Device Component

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A CAPTIVATOR COLD SNARE WAS USED IN THE COLON DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE PHYSICIAN SUCCESSFULLY COLD CUT THE POLYP, BUT AFTER CLOSING IT, THE LOOP DETACHED COMPLETELY FROM THE DEVICE AND FELL OUT INTO THE COLON. THE PIECE BECAME EMBEDDED IN PATIENTS TISSUE AND HAD TO BE RETRIEVED USING A RESCUE NET SNARE. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25524948 ↗
  • MalfunctionJun 15, 2026Failure to Cut; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC THAT A COLD SNARE WAS USED FOR A POLYPECTOMY PROCEDURE PERFORMED ON AN UNKNOWN DATE. DURING THE PROCEDURE THE SNARE FAILED TO CUT THE POLYP. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25498616 ↗
  • MalfunctionJun 1, 2026Detachment of Device or Device Component

    IT WAS REPORTED TO BOSTON SCIENTIFIC THAT A COLD SNARE WAS USED FOR A POLYP REMOVAL, DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE SNARE LOOP DETACHED FROM THE DEVICE. THE LOOP WAS REMOVED FROM THE PATIENT WITH THE SAME DEVICE. THE PROCEDURE WAS COMPLETED WITH ANOTHER SNARE. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25356317 ↗
  • MalfunctionApr 28, 2026Detachment of Device or Device Component

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A COLD SNARE DEVICE WAS USED FOR POLYPECTOMY DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, A METAL PIECE OF THE SNARE CAME OUT OF THE PLASTIC. THE PROCEDURE WAS COMPLETED WITH ANOTHER COLD SNARE DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. NO FURTHER INFORMATION HAS BEEN OBTAINED DESPITE GOOD FAITH EFFORTS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25021462 ↗
  • MalfunctionApr 28, 2026Failure to Cut; Difficult to Open or Close

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A CAPTIVATOR COLD SNARE WAS USED IN THE COLON DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE PHYSICIAN TRIED TO CUT THE POLYP AND THE SNARE WAS UNABLE TO CUT COLD. THE SNARE WAS ACTUATING WITH RESISTANCE WHEN TRYING TO OPEN. THE PROCEDURE WAS COMPLETED WITH THE ORIGINAL DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25017826 ↗
  • MalfunctionApr 16, 2026

    FROM STAFF: UPON OPENING SNARE FROM PACKAGING TO PREPARE FOR CASE, THE DEVICE BUCKLED AND WAS NOT FUNCTIONAL.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24895125 ↗
  • MalfunctionMar 30, 2026Break; Material Integrity Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A COLD SNARE WAS USED IN THE COLON DURING A COLONOSCOPY. THE EXACT PROCEDURE DATE WAS UNKNOWN. IT WAS REPORTED THAT THE WIRE SNAPPED DURING POLYP REMOVAL. THE PROCEDURE WAS COMPLETED, ALTHOUGH THERE WAS NO INFORMATION REGARDING WHICH DEVICE WAS USED TO FINISH THE CASE. THE PATIENT SUBSEQUENTLY UNDERWENT AN MRI, AND THE SCOPE INVOLVED IN THE EVENT IS CURRENTLY BEING REPAIRED. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. NO FURTHER INFORMATION HAS BEEN OBTAINED DESPITE GOOD FAITH EFFORTS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24717368 ↗
  • MalfunctionMar 25, 2026Failure to Cut

    IT WAS REPORTED TO BOSTON SCIENTIFIC THAT A CAPTIVATOR COLD SNARE WAS USED IN THE COLON FOR A POLYPECTOMY REMOVAL PROCEDURE, PERFORMED ON AN UNKNOWN DATE. DURING THE PROCEDURE, THE SNARE FAILED TO CUT THE POLYP. THE PROCEDURE WAS COMPLETED WITH AN ALTERNATE DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24690876 ↗
  • MalfunctionMar 24, 2026Failure to Cut

    IT WAS REPORTED TO BOSTON SCIENTIFIC THAT A CAPTIVATOR COLD SNARE WAS USED IN THE COLON FOR A POLYPECTOMY REMOVAL PROCEDURE, PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE SNARE FAILED TO CUT THE POLYP. THE PROCEDURE WAS COMPLETED WITH AN ALTERNATE DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24680716 ↗
  • MalfunctionMar 24, 2026Failure to Cut

    IT WAS REPORTED TO BOSTON SCIENTIFIC THAT A CAPTIVATOR COLD SNARE WAS USED IN THE COLON FOR A POLYPECTOMY REMOVAL PROCEDURE, PERFORMED ON AN UNKNOWN DATE. DURING THE PROCEDURE, THE SNARE FAILED TO CUT THE POLYP. THE PROCEDURE WAS COMPLETED WITH AN ALTERNATE DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24680645 ↗
  • MalfunctionMar 24, 2026Failure to Cut

    IT WAS REPORTED TO BOSTON SCIENTIFIC THAT A CAPTIVATOR COLD SNARE WAS USED IN THE COLON FOR A POLYPECTOMY REMOVAL PROCEDURE, PERFORMED ON AN UNKNOWN DATE. DURING THE PROCEDURE, THE SNARE FAILED TO CUT THE POLYP. THE PROCEDURE WAS COMPLETED WITH AN ALTERNATE DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24674483 ↗
  • MalfunctionMar 24, 2026Failure to Cut

    IT WAS REPORTED TO BOSTON SCIENTIFIC THAT A CAPTIVATOR COLD SNARE WAS USED IN THE COLON FOR A POLYPECTOMY REMOVAL PROCEDURE, PERFORMED ON AN UNKNOWN DATE. DURING THE PROCEDURE, THE SNARE FAILED TO CUT THE POLYP. THE PROCEDURE WAS COMPLETED WITH AN ALTERNATE DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24674475 ↗
  • MalfunctionMar 17, 2026Break

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A CAPTIVATOR COLD SINGLE-USE SNARE WAS USED DURING A COLONOSCOPY FOR THE TREATMENT OF POLYPS, ON (B)(6) 2026. DURING THE PROCEDURE, THE LOOP SNAPPED. THE PROCEDURE WAS COMPLETED WITH ANOTHER CAPTIVATOR COLD SINGLE-USE SNARE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24619284 ↗
  • MalfunctionMar 16, 2026Failure to Cut

    IT WAS REPORTED TO BOSTON SCIENTIFIC THAT A CAPTIVATOR COLD SNARE WAS USED IN THE COLON FOR A POLYPECTOMY PROCEDURE PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE CAPTIVATOR COLD SNARE FAILED TO CUT THE POLYP. ANOTHER UNKNOWN ALTERNATIVE METHOD WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24605980 ↗
  • InjuryMar 9, 2026Break; Detachment of Device or Device Component

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A COLD SNARE WAS USED IN THE COLON DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6), 2026. IT WAS REPORTED THAT THE PROCEDURE TOOK LONGER BECAUSE THE STAFF HAD TO WITHDRAW THE SNARE AND RETRIEVE IT USING A GRASPING FORCEPS. IN ADDITION, THE SNARE TIP HAD MIGRATED INTO THE LUMEN OF THE GUT. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24542361 ↗
  • MalfunctionFeb 24, 2026Failure to Cut

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A CAPTIVATOR COLD SINGLE-USE SNARE DEVICE WAS USED DURING A POLYPECTOMY PROCEDURE ON (B)(6) 2026, FOR THE TREATMENT OF POLYPS REMOVAL. DURING THE PROCEDURE, THE LOOP WOULD NOT CUT THROUGH THE POLYP. TROUBLESHOOTING STEPS WERE ATTEMPTED TO RESOLVE THE ISSUE, INCLUDING TRYING NUMEROUS TIMES. DESPITE THESE EFFORTS, THE PHYSICIAN HAD TO CHANGE THE DEVICE WITH ANOTHER OF THE SAME TO COMPLETE THE PROCEDURE. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24428161 ↗
  • MalfunctionFeb 18, 2026Retraction Problem; Difficult to Open or Close

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A CAPTIVATOR COLD SINGLE-USE SNARE WAS USED DURING A POLYP RETRIEVAL PROCEDURE ON (B)(6) 2026. DURING THE PROCEDURE, IT WAS DIFFICULT TO CLOSE THE SNARE SLOWLY AROUND THE POLYP. THE SNARE CLOSED RAPIDLY, RESULTING IN INADVERTENT CUTTING OF THE POLYP. THE POLYP WAS RETRIEVED, BUT NOT IN THE MANNER THE PHYSICIAN INTENDED. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24381411 ↗
  • MalfunctionFeb 4, 2026Failure to Cut

    NOTE: THIS REPORT PERTAINS TO FIRST OF THREE COLD SNARES USED DURING THE SAME PROCEDURE. IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A COLD SNARE WAS USED IN THE TRANSVERSE COLON DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE SNARE WAS UNABLE TO CUT THE POLYP. THE PROCEDURE WAS COMPLETED WITH ANOTHER COLD SNARE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24262093 ↗
  • MalfunctionJan 30, 2026Break; Failure to Cut

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A COLD SNARE WAS USED IN THE COLON DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6) 2026. IT WAS REPORTED THAT THE SNARES WERE INITIALLY UNABLE TO FULLY CUT THE POLYP, AND WHEN THEY EVENTUALLY DID, THE SNARE WIRE BROKE. THE PROCEDURE WAS THEN COMPLETED USING ANOTHER COLD SNARE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24220216 ↗
  • MalfunctionJan 29, 2026Failure to Cut

    NOTE: THIS REPORT PERTAINS TO THE FIFTH OF FIVE COLD SNARES USED DURING THE SAME PROCEDURE. IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A COLD SNARE WAS USED IN THE COLON DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE SNARES WOULD NOT CUT TISSUE ON SMALL, DIMINUTIVE POLYPS. A FIFTH COLD SNARE WAS USED; HOWEVER, THE SAME PROBLEM HAPPENED. THE PROCEDURE WAS COMPLETED WITH ANOTHER COLD SNARE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24214511 ↗
  • MalfunctionJan 28, 2026Failure to Cut

    NOTE: THIS REPORT PERTAINS TO SECOND OF FIVE COLD SNARE USED DURING THE SAME PROCEDURE. IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A COLD SNARE WAS USED IN THE COLON DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE SNARES WOULD NOT CUT TISSUE ON SMALL, DIMINUTIVE POLYPS. A SECOND COLD SNARE WAS USED; HOWEVER, THE SAME PROBLEM HAPPENED. THE PROCEDURE WAS COMPLETED WITH ANOTHER COLD SNARE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24203605 ↗
  • MalfunctionJan 28, 2026Nonstandard Device; Retraction Problem; Failure to Cut; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A COLD SNARE DEVICE WAS USED DURING A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6) 2026. DURING THE PROCEDURE, THE SNARE WOULD NOT CUT THE TISSUE OF SMALLER POLYPS. IT IS ASSUMED THAT THE HDPE SHEATH IS BEING TRIMMED TOO SHORT, PREVENTING THE LOOP FROM RETRACTING PROPERLY INTO THE SHEATH. THE PROCEDURE WAS COMPLETED WITH ANOTHER COLD SNARE DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24203600 ↗
  • MalfunctionJan 28, 2026Nonstandard Device; Retraction Problem; Failure to Cut; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A COLD SNARE DEVICE WAS USED DURING A COLONOSCOPY PROCEDURE PERFORMED ON(B)(6) 2026. DURING THE PROCEDURE, THE SNARE WOULD NOT CUT THE TISSUE OF SMALLER POLYPS. IT IS ASSUMED THAT THE HDPE SHEATH IS BEING TRIMMED TOO SHORT, PREVENTING THE LOOP FROM RETRACTING PROPERLY INTO THE SHEATH. THE PROCEDURE WAS COMPLETED WITH ANOTHER COLD SNARE DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24203589 ↗

FDA clearance and classification

The FDA regulates product code FGX (snare, non-electrical) under 21 CFR 876.4730 as a Class I device. 21 CFR 876.4730 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Captivator™ COLD M00561100

Has the Captivator™ COLD M00561100 been recalled?

No FDA recall record in our data names this exact device identifier (DI 08714729971252), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Captivator™ COLD M00561100?

The FDA's MAUDE database lists 371 adverse event reports for this device, received between Nov 19, 2018 and Sep 18, 2026. In those reports, the most common specific device problems are “Failure to Cut” (258), “Break” (50) and “Detachment of Device or Device Component” (38); the most common patient problems are “Hemorrhage/Blood Loss/Bleeding” (11), “Unspecified Tissue Injury” (10) and “Exposure to Body Fluids” (3). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Captivator™ COLD M00561100?

None of the reports are classified as deaths, 38 as injuries and 333 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Captivator™ COLD M00561100 FDA approved?

Devices of this type (product code FGX) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Boston Scientific Corporation.

Who makes the Captivator™ COLD M00561100, and is it still sold?

The FDA's device database lists Boston Scientific Corporation as the company responsible for it (brand Captivator™ COLD, model M00561100). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.