Boston Scientific Corporation · Fully Covered Stent System · Class 2 · Implant

All models of Agile Esophageal (16)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 08714729973089), received between Nov 23, 2021 and Aug 19, 2026 — classified as 2 injuries, 4 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Migration2
  • Device-Device Incompatibility1
  • Material Deformation1
  • Positioning Failure1
  • Positioning Problem1
  • Premature Activation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 19, 2026Device-Device Incompatibility; Positioning Problem

    Note: This report pertains to an Agile Esophageal Stent and Overstitch NXT used during the same procedure.It was reported to Boston Scientific Corporation that an Agile Esophageal Fully Covered TTS stent was attempted to be implanted during an Esophagogastroduodenoscopy (EGD) procedure performed on (b)(6) 2026. During the procedure, the Agile stent was successfully placed; however, during scope removal, the stent became caught on the OverStitch needle driver and had to be forcibly removed. The procedure was completed using another Agile Esophageal TTS stent. There were no patient complications associated with this event and the patient condition following the procedure was reported as stable.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50334618 ↗
  • InjuryJan 30, 2025Migration; Migration

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN AGILE ESOPHAGEAL FULLY COVERED STENT TTS WAS IMPLANTED IN THE ESOPHAGUS TO TREAT AN ESOPHAGEAL STRICTURE DURING AN ESOPHAGOGASTRODUODENOSCOPY (EGD) WITH STENT PLACEMENT PROCEDURE PERFORMED ON (B)(6) 2024. DURING THE PROCEDURE, THE STENT WAS SUCCESSFULLY DEPLOYED. THE PATIENT UNDERWENT THERAPY, AND IT WAS NOTED THAT THE STENT HAD MIGRATED. ANOTHER WALLFLEX STENT WAS PLACED, AND THE PHYSICIAN PLANS TO REMOVE THE MIGRATED STENT IN APPROXIMATELY 3 WEEKS. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21280068 ↗
  • MalfunctionFeb 29, 2024Migration; Migration

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN AGILE ESOPHAGEAL FULLY COVERED STENT WAS IMPLANTED IN THE ESOPHAGUS TO TREAT A 9CM MALIGNANT STRICTURE DURING AN UPPER GASTROINTESTINAL (GI) ENDOSCOPY WITH STENT PLACEMENT PROCEDURE PERFORMED ON (B)(6) 2022. THE PATIENT'S ANATOMY WAS TORTUOUS AND WAS DILATED PRIOR TO STENT PLACEMENT PROCEDURE. THE STENT WAS SCHEDULED TO BE REMOVED ON (B)(6) 2022. DURING THE STENT REMOVAL PROCEDURE, IT WAS NOTED THAT THE STENT HAD COMPLETELY MIGRATED DISTALLY DUE TO STRICTURE RESOLUTION. THE STENT WAS FOUND IN THE STOMACH AND WAS REMOVED USING RAT-TOOTH FORCEPS, AND THE PROCEDURE WAS COMPLETED. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18813183 ↗
  • InjuryDec 27, 2023Premature Activation; Premature Activation

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN AGILE ESOPHAGEAL FULLY COVERED STENT WAS TO BE IMPLANTED IN THE ESOPHAGUS TO TREAT AN ESOPHAGEAL STRICTURE DUE TO ESOPHAGEAL CANCER DURING AN ESOPHAGOGASTRODUODENOSCOPY (EGD) WITH STENT PLACEMENT PROCEDURE PERFORMED ON (B)(6) 2023. THE PATIENT'S ANATOMY WAS TORTUOUS AND WAS NOT DILATED PRIOR TO STENT PLACEMENT. DURING THE PROCEDURE, THE STENT PREMATURELY DEPLOYED. THE STENT WAS REMOVED USING RAT TOOTH FORCEPS AND ANOTHER AGILE ESOPHAGEAL STENT WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18399113 ↗
  • MalfunctionMar 27, 2023Break; Positioning Failure; Material Deformation; Break; Positioning Failure; Material Deformation

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION ON (B)(6) 2023 THAT AN AGILE ESOPHAGEAL FULLY COVERED STENT WAS USED TO TREAT AN ESOPHAGEAL CANCER DURING AN ESOPHAGOGASTRODUODENOSCOPY (EGD) WITH STENT PLACEMENT PROCEDURE PERFORMED ON (B)(6) 2023. THE PATIENT'S ANATOMY WAS TIGHT AND WAS NOT DILATED PRIOR TO STENT PLACEMENT PROCEDURE. DURING THE PROCEDURE, WHEN THE STENT WAS BEING DEPLOYED, IT WAS NOTICED THAT THE OUTER BLUE SHEATH WAS KINKED. SUBSEQUENTLY, A SNAP WAS HEARD AND THE STENT WAS UNABLE TO BE FULLY DEPLOYED. THE STENT WAS RECONSTRAINED AND WAS FULLY COVERED BY THE OUTER SHEATH WHEN IT WAS REMOVED FROM THE PATIENT. THE PROCEDURE WAS NOT COMPLETED DUE TO DEVICE AVAILABILITY. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16620454 ↗
  • MalfunctionNov 23, 2021Break; Break

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION ON (B)(6), 2021 THAT AN AGILE ESOPHAGEAL FULLY COVERED STENT WAS IMPLANTED IN THE ESOPAHAGUS TO TREAT AN ESOPHAGEAL STRICTURE DURING A STENT PLACEMENT PROCEDURE PERFORMED SIX MONTHS AGO. ON (B)(6) 2021, DURING A SCHEDULED STENT REMOVAL PROCEDURE, AFTER THE STENT WAS REMOVED FROM THE PATIENT WITH FORCEPS, THE PHYSICIAN NOTICED THAT THE METAL WELDS OF THE STENT WERE SEPARATED. THE STENT REMOVAL PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12863151 ↗

Other PROSTHESIS, ESOPHAGEAL devices

All PROSTHESIS, ESOPHAGEAL devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page