SYNERGY™ XD H7493941820500Recalls & reported problems

Boston Scientific Corporation · Everolimus-Eluting Platinum Chromium Coronary Stent System · Class 3 · Implant

All models of SYNERGY XD (65)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 08714729981268), received between Jun 2, 2021 and Jan 8, 2025 — classified as 1 injury, 5 malfunctions.

The most frequently reported specific device problem is “Difficult to Remove” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Remove3
  • Break2
  • Deflation Problem1
  • Detachment of Device or Device Component1
  • Entrapment of Device1
  • Failure to Deflate1
  • Fracture1
  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 8, 2025Material Rupture; Material Rupture

    IT WAS REPORTED VIA MEDWATCH (B)(4) THAT BALLOON RUPTURE OCCURRED. A 5.00 X 20MM SYNERGY XD DRUG-ELUTING STENT WAS ADVANCED FOR TREATMENT. HOWEVER, IT WAS NOTED THAT THE BALLOON FROM THE STENT WAS RUPTURED. THEN THE FRACTURE OF THE BALLOON SHAFT WHILE DELIVERING THE SECOND STENT REQUIRED TRAPPING AND SNARING OF THE STENT TO REMOVED FROM THE BODY. THE PROCEDURE WAS COMPLETED AND THERE WERE NO PATIENT COMPLICATIONS REPORTED. NO PATIENT HARMED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21102266 ↗
  • MalfunctionApr 19, 2024Entrapment of Device; Detachment of Device or Device Component; Failure to Deflate; Entrapment of Device; Detachment of Device or Device Component; Failure to Deflate

    IT WAS REPORTED VIA MEDWATCH (B)(4) THAT DEFLATION FAILURE, DEVICE ENTRAPMENT AND DEVICE DETACHMENT OCCURRED. THE TARGET LESION WAS LOCATED IN THE CORONARY ARTERY. A 5.0 X 20 MM SYNERGY XD DRUG-ELUTING STENT WAS ADVANCED FOR TREATMENT. AFTER DEPLOYMENT OF THE STENT, THE BALLOON COULD NOT BE FULLY DEFLATED, CAUSING IT TO BECOME TRAPPED IN THE WIRE AND THE GUIDE. WHEN ATTEMPTING TO RETRIEVE THE STENT BALLOON, IT BROKE OFF FROM THE STENT DELIVERY SHAFT. NO FURTHER DETAILS WERE REPORTED IN RELATION TO THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19148043 ↗
  • MalfunctionJun 30, 2022Break; Difficult to Remove; Break; Difficult to Remove

    IT WAS REPORTED THAT REMOVAL DIFFICULTIES AND SHAFT BREAK OCCURRED. A 5.00 X 20MM SYNERGY DRUG-ELUTING STENT WAS SELECTED FOR SAPHENOUS VEIN GRAFT (SVG) PERCUTANEOUS CORONARY INTERVENTIONS (PCI) PROCEDURE. DURING THE PROCEDURE, THE BALLOON INFLATED AND STENT FULLY DEPLOYED AT 22 ATMOSPHERES. THE BALLOON BECAME STUCK ON THE GUIDE CATHETER WITHIN THE SVG AND WHEN THE PHYSICIAN ATTEMPTED TO REMOVE IT, THE CATHETER SHAFT FRACTURED AT THE GUIDEWIRE EXIT PORT. THE DEVICE WAS REMOVED AND THE PROCEDURE COMPLETED SUCCESSFULLY WITH THIS DEVICE. THERE WAS NO PATIENT COMPLICATIONS; THE PATIENT STATUS WAS STABLE AND THEY WERE DISCHARGED POST PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14875422 ↗
  • InjuryJan 20, 2022Break; Fracture; Difficult to Remove; Break; Fracture; Difficult to Remove

    IT WAS REPORTED THAT REMOVAL DIFFICULTIES, DEVICE DETACHMENT AND ADDITIONAL INTERVENTION OCCURRED. A GUIDEZILLA II GUIDE EXTENSION CATHETER WAS ADVANCED TO THE TARGET LESION IN THE MID RIGHT CORONARY ARTERY (RCA) WHICH WAS NOTED TO BE VERY LARGE. A 5.00 X 20MM SYNERGY BALLOON EXPANDABLE STENT WAS ADVANCED AND THE STENT WAS SUCCESSFULLY DEPLOYED. DURING REMOVAL OF THE SYNERGY STENT DELIVERY SYSTEM BACK INTO THE GUIDEZILLA II, THE CATHETER BECAME STUCK. THE GUIDEZILLA II, SYNERGY DELIVERY SYSTEM CATHETER AND GUIDEWIRE WERE ALL REMOVED AS ONE UNIT. 8CM OF THE SYNERGY STENT DELIVERY SYSTEM BROKE OFF INSIDE THE PATIENT NEAR THE DISTAL SHEATH TIP. THE DETACHED PORTION WAS SUCCESSFULLY REMOVED USING A SNARE. THE PROCEDURE WAS COMPLETED AND THE PATIENT FULLY RECOVERED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13307937 ↗
  • MalfunctionJul 1, 2021Deflation Problem; Difficult to Remove; Deflation Problem; Difficult to Remove

    IT WAS REPORTED THAT DEFLATION FAILURE OCCURRED. THE 80%STENOSED TARGET LESION WAS LOCATED IN THE NON TORTUOUS AND NON CALCIFIED SAPHENOUS VEIN GRAFT. A 5.00 X 20MM SYNERGY XD DRUG-ELUTING STENT WAS DEPLOYED AT NOMINAL PRESSURE FOR TREATMENT. POST STENT DEPLOYMENT, IT WAS OBSERVED THAT THE BALLOON DID NOT DEFLATE PROPERLY AND THE BALLOON DID NOT REWRAP. AFTER THE BALLOON WAS DEFLATED FOR ONE MINUTE, AN ATTEMPT WAS MADE TO REMOVE THE BALLOON BUT IT WOULD NOT GO BACK INTO THE 6 FR GUIDE CATHETER. AN INDEFLATOR WAS ATTACHED AND PULLED NEGATIVE PRESSURE SEVERAL TIMES AND THE BALLOON WAS FINALLY PULLED BACK INTO THE GUIDE CATHETER AND REMOVED IN PARTIALLY INFLATED STATE TO COMPLETE THE PROCEDURE. THERE WERE NO PATIENT COMPLICATIONS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12105173 ↗
  • MalfunctionJun 2, 2021Material Deformation; Material Deformation

    IT WAS REPORTED THAT STENT DAMAGE OCCURRED. A 5.00 X 20MM SYNERGY XD DRUG-ELUTING STENT WAS ADVANCED FOR TREATMENT. HOWEVER, WHEN THE DEVICE WAS REMOVED FROM THE PATIENT, THE STENT STRUTS WERE LIFTED. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF SAME DEVICE WITH NO ISSUES. THERE WERE NO PATIENT COMPLICATIONS NOR INJURIES REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11926374 ↗

Other Coronary drug-eluting stent devices

All Coronary drug-eluting stent devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page