SYNERGY MEGATRON™ H7493942820450Recalls & reported problems
Boston Scientific Corporation · Everolimus-Eluting Platinum Chromium Coronary Stent System · Class 3 · Implant
All models of SYNERGY MEGATRON (28)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 08714729985679), received between May 5, 2021 and May 16, 2023 — classified as 2 injuries.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break2
- Adverse Event Without Identified Device or Use Problem1
- Device Dislodged or Dislocated1
- Entrapment of Device1
- Material Deformation1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMay 16, 2023Break; Entrapment of Device; Material Deformation; Break; Entrapment of Device; Material Deformation
IT WAS REPORTED THAT DEVICE ENTRAPMENT, SHAFT BREAK, AND STENT DAMAGE OCCURRED. THE PATIENT WAS BEING TREATED FOR CORONARY ARTERY DISEASE IN THE LEFT MAIN ARTERY LESION USING IMPELLA SUPPORT. FOLLOWING DEPLOYMENT OF A 4.50 X 20MM SYNERGY MEGATRON DRUG-ELUTING STENT, THE STENT BALLOON WAS WITHDRAWN BUT IT COULD NOT BE REMOVED FROM THE GUIDE CATHETER AND WOULD NOT MOVE. BALLOON ADVANCEMENT WAS ATTEMPTED AND TO RE-INFLATE, BUT ADVANCEMENT WAS NOT POSSIBLE. NO DEVICES WERE ABLE TO MOVE PAST THE BALLOON THAT WAS STUCK IN THE GUIDE CATHETER, AN ATTEMPT TO PULL WAS DONE AND THE BALLOON SHAFT BROKE OFF OF THE DELIVERY SYSTEM. THE BROKEN SHAFT AND BALLOON WERE RETRIEVED AFTER MANY HOURS TRYING TO USE A SNARE. FOLLOWING REMOVAL, IT WAS NOTED THAT THE STENT WAS STILL ATTACHED TO THE BALLOON BUT WAS MANGLED AND DEFORMED. THE PROCEDURE WAS COMPLETED WITH A SYNERGY XD DRUG-ELUTING STENT AND THE PATIENT WAS FULLY RECOVERED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16940285 ↗InjuryMay 5, 2021Break; Device Dislodged or Dislocated; Adverse Event Without Identified Device or Use Problem; Break; Device Dislodged or Dislocated; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE STENT MOVED ON THE BALLOON AND A SHAFT BREAK OCCURRED. THE TARGET LESION WAS LOCATED IN A RE-STENOSED PREVIOUSLY PLACED STENT LOCATED IN THE PROXIMAL LEFT ANTERIOR DESCENDING ARTERY (LAD) INTO THE LEFT MEAN. THE 4.50 X 20MM SYNERGY MEGATRON STENT WAS SELECTED FOR TREATMENT. A 7 FRENCH GUIDE CATHETER AND A GUIDEWIRE WAS ADVANCED THROUGH THE LAD AND ANOTHER GUIDEWIRE WAS PLACED IN THE CIRCUMFLEX ARTERY. THE RE-STENOSED STENT WAS EXPANDED AND A SYNERGY XD 3.5 X 20 AND A SYNERGY XD 3.0 X 20 WAS ADVANCED THROUGH THE PREVIOUSLY PLACED STENT WITHOUT STENT INTERACTION. WHEN ATTEMPTING TO STENT FROM THE OSTIUM OF THE CIRCUMFLEX BACK INTO THE LEFT MAIN. THE 4.50 X 20MM SYNERGY MEGATRON WAS ADVANCED THROUGH THE GUIDE AND INTO THE LEFT BEING A CIRQUE AND A POP WAS HEARD. THERE WAS AN ATTEMPT TO REMOVE THE DELIVERY SYSTEM, BUT ONLY 95% OF THE STENT DELIVERY SYSTEM WAS RETRIEVED. FIVE INCHES OF THE STENT DELIVERY SYSTEM REMAINED IN THE GUIDE CATHETER IN THE LEFT MAIN. UPON REMOVAL OF THE GUIDE CATHETER, THE DETACHED PORTION OF THE SYNERGY MEGATRON DELIVERY SYSTEM WAS FLOATING IN THE AORTA. THE DETACHED PORTION WAS REMOVED WITH A SNARE. THE PROCEDURE WAS COMPLETED AND NO
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11780031 ↗
Other Coronary drug-eluting stent devices
- SYNERGY™ H7493926038300Boston Scientific Corporation · Coronary drug-eluting stent8 deaths124 reports
- SYNERGY™ H7493926016300Boston Scientific Corporation · Coronary drug-eluting stent7 deaths106 reports
- SYNERGY™ H7493926020300Boston Scientific Corporation · Coronary drug-eluting stent9 deaths90 reports
- SYNERGY™ H7493926016250Boston Scientific Corporation · Coronary drug-eluting stent6 deaths82 reports
- XIENCE Sierra™ 1550350-33Abbott Vascular Inc. · Coronary drug-eluting stent1 recall32 reports
- Resolute Onyx™ RONYX30022UXMedtronic, Inc. · Coronary drug-eluting stent6 deaths76 reports
- SYNERGY™ H7493926024300Boston Scientific Corporation · Coronary drug-eluting stent3 deaths75 reports
- Resolute Onyx™ RONYX30015UXMedtronic, Inc. · Coronary drug-eluting stent3 deaths73 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page