ROTAPRO™ H749394672250Recalls & reported problems

Boston Scientific Corporation · Pre-Connected Exchangeable Burr Catheter and Burr Advancing Device · Class 3

All models of ROTAPRO (14)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 08714729999614), received between Mar 3, 2025 and Jul 31, 2026 — classified as 3 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Entrapment of Device” (3 reports).

4 other recalls cover devices cleared under the same FDA submission (P900056); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 3 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Entrapment of Device3
  • Adverse Event Without Identified Device or Use Problem1
  • Difficult to Remove1
  • Intermittent Loss of Power1
  • Material Separation1
  • Nonstandard Device1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Myocardial Infarction1
  • Unintended Radiation Exposure1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 31, 2026Nonstandard Device; Difficult to Remove; Material Separation; Intermittent Loss of Power

    It was reported that the burr detached.The 90% stenosed target lesion was located in the tortuous and calcified mid to distal right coronary artery. A 2.25mm Rotapro was selected for use. During the procedure, it was noted that a Rotalink separated between the burr and the drive shaft. During removal, resistance was encountered. The fragments were successfully retrieved using a gooseneck snare, and no fragments remained inside the patient's body following the procedure. Per the physician this event occurred due to possible device deterioration resulting from repeated ablation attempts in a severely tortuous vessel, with repeated stall indications being displayed. The procedure was completed with a different device. There were no patient complications, and the patient was in good condition after the procedure.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50104976 ↗
  • MalfunctionApr 30, 2026Entrapment of Device

    IT WAS REPORTED THAT VIA LITERATURE ARTICLE THAT BURR ENTRAPMENT OCCURRED. THIS STUDY AIMED TO EVALUATE THE EFFECTIVENESS OF ROTATIONAL ATHERECTOMY FOR THE TREATMENT OF STENT DEFORMATION ASSOCIATED WITH CALCIFIED PLAQUES. 13 CONSECUTIVE PATIENTS PRESENTING WITH ANGINA PECTORIS SECONDARY TO STENT DEFORMATION CAUSED BY SEVERE CALCIFICATION WERE TREATED BETWEEN DECEMBER 2010 AND DECEMBER 2023. ROTATIONAL ATHERECTOMY WAS PERFORMED TO ABLATE BOTH THE DEFORMED STENT STRUTS AND THE UNDERLYING CALCIFIED PLAQUES. ALL PATIENTS RECEIVED ASPIRIN (100 MG), TICLOPIDINE HYDROCHLORIDE (200 MG), CLOPIDOGREL BISULFATE (75 MG), OR PRASUGREL HYDROCHLORIDE (3.75 MG) ORALLY. A 7F OR 8F ARTERIAL SHEATH WAS USED IN THE PERCUTANEOUS TRANSLUMINAL CORONARY ROTATIONAL ATHERECTOMY (PTCRA) PROCEDURE. A TEMPORARY PACEMAKER WAS INSERTED TRANSFEMORALLY THROUGH A 6F SHEATH. A 0.009-INCH ROTAWIRE EXTRA SUPPORT GUIDEWIRE WITH A 0.014-INCH TIP (BOSTON SCIENTIFIC (BSC) WAS PASSED THROUGH THE LESION TO THE DISTAL CORONARY ARTERY. IN THE FIRST STEP, STENTABLATION WAS PERFORMED, IN WHICH A BURR OF THE OPTIMAL SIZE WAS USED TO ABLATE THE DEFORMED STENT STRUTS. IN THE SECOND STEP, THE BURR SIZE WAS INCREASED AS NEEDED TO AB

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25045401 ↗
  • InjuryApr 30, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT VIA LITERATURE ARTICLE THAT POST PROCEDURE MYOCARDIAL INFARCTION OCCURRED. THIS STUDY AIMED TO EVALUATE THE EFFECTIVENESS OF ROTATIONAL ATHERECTOMY FOR THE TREATMENT OF STENT DEFORMATION ASSOCIATED WITH CALCIFIED PLAQUES. 13 CONSECUTIVE PATIENTS PRESENTING WITH ANGINA PECTORIS SECONDARY TO STENT DEFORMATION CAUSED BY SEVERE CALCIFICATION WERE TREATED BETWEEN DECEMBER 2010 AND DECEMBER 2023. ROTATIONAL ATHERECTOMY WAS PERFORMED TO ABLATE BOTH THE DEFORMED STENT STRUTS AND THE UNDERLYING CALCIFIED PLAQUES. ALL PATIENTS RECEIVED ASPIRIN (100 MG), TICLOPIDINE HYDROCHLORIDE (200 MG), CLOPIDOGREL BISULFATE (75 MG), OR PRASUGREL HYDROCHLORIDE (3.75 MG) ORALLY. A 7F OR 8F ARTERIAL SHEATH WAS USED IN THE PERCUTANEOUS TRANSLUMINAL CORONARY ROTATIONAL ATHERECTOMY (PTCRA) PROCEDURE. A TEMPORARY PACEMAKER WAS INSERTED TRANSFEMORALLY THROUGH A 6F SHEATH. A 0.009-INCH ROTAWIRE EXTRA SUPPORT GUIDEWIRE WITH A 0.014-INCH TIP (BOSTON SCIENTIFIC (BSC) WAS PASSED THROUGH THE LESION TO THE DISTAL CORONARY ARTERY. IN THE FIRST STEP, STENTABLATION WAS PERFORMED, IN WHICH A BURR OF THE OPTIMAL SIZE WAS USED TO ABLATE THE DEFORMED STENT STRUTS. IN THE SECOND STEP, THE BURR SIZE WAS INCR

    Patient problems: Myocardial Infarction

    MAUDE report 25045399 ↗
  • MalfunctionApr 30, 2026Entrapment of Device

    IT WAS REPORTED THAT VIA LITERATURE ARTICLE THAT DEVICE ENTRAPMENT OCCURRED. THIS STUDY AIMED TO EVALUATE THE EFFECTIVENESS OF ROTATIONAL ATHERECTOMY FOR THE TREATMENT OF STENT DEFORMATION ASSOCIATED WITH CALCIFIED PLAQUES. 13 CONSECUTIVE PATIENTS PRESENTING WITH ANGINA PECTORIS SECONDARY TO STENT DEFORMATION CAUSED BY SEVERE CALCIFICATION WERE TREATED BETWEEN DECEMBER 2010 AND DECEMBER 2023. ROTATIONAL ATHERECTOMY WAS PERFORMED TO ABLATE BOTH THE DEFORMED STENT STRUTS AND THE UNDERLYING CALCIFIED PLAQUES. ALL PATIENTS RECEIVED ASPIRIN (100 MG), TICLOPIDINE HYDROCHLORIDE (200 MG), CLOPIDOGREL BISULFATE (75 MG), OR PRASUGREL HYDROCHLORIDE (3.75 MG) ORALLY. A 7F OR 8F ARTERIAL SHEATH WAS USED IN THE PERCUTANEOUS TRANSLUMINAL CORONARY ROTATIONAL ATHERECTOMY (PTCRA) PROCEDURE. A TEMPORARY PACEMAKER WAS INSERTED TRANSFEMORALLY THROUGH A 6F SHEATH. A 0.009-INCH ROTAWIRE EXTRA SUPPORT GUIDEWIRE WITH A 0.014-INCH TIP (BOSTON SCIENTIFIC (BSC) WAS PASSED THROUGH THE LESION TO THE DISTAL CORONARY ARTERY. IN THE FIRST STEP, STENTABLATION WAS PERFORMED, IN WHICH A BURR OF THE OPTIMAL SIZE WAS USED TO ABLATE THE DEFORMED STENT STRUTS. IN THE SECOND STEP, THE BURR SIZE WAS INCREASED AS NEEDED TO

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25045382 ↗
  • InjuryMar 3, 2025Entrapment of Device; Entrapment of Device

    IT WAS REPORTED THAT THE BURR WAS STUCK IN LESION. THE 80-90% STENOSED TARGET LESION WAS LOCATED IN THE MODERATELY ANGULATED AND SEVERELY CALCIFIED RIGHT CORONARY ARTERY. A 2.25MM ROTAPRO WAS SELECTED FOR USE. DURING THE PROCEDURE, THE BURR BECAME STUCK IN THE LESION. SEVERAL MANEUVERS WERE DONE IN AN ATTEMPT TO FREE THE BURR. FIRST, DYNAGLIDE WAS USED WITH TRACTION UNSUCCESSFULLY. NEXT, A SECOND WIRE WAS ADVANCED PAST THE BURR AND A BALLOON WAS INFLATED NEXT TO THE BURR FOLLOWED BY TRACTION, WHICH WAS ALSO UNSUCCESSFUL. ULTIMATELY, THE BURR SHAFT WAS CUT, AND A NON-BOSTON SCIENTIFIC GUIDE EXTENSION CATHETER WAS ADVANCED TO THE BURR. THE BURR WAS COMPLETELY REMOVED FROM THE PATIENT BODY. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE AND WAS PROLONGED RESULTING IN EXCESS OF 6 GY OF RADIATION. THE PATIENT CONDITION WAS STABLE POST PROCEDURE.

    Patient problems: Unintended Radiation Exposure

    MAUDE report 21504814 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P900056. One submission often covers many models, so check the product and lot details in each record.

  • Z-0916-2022 · Mar 8, 2022 · Open, Classified
    ROTAWIRE Drive and wireClip Torquer, ROTAWIRE Drive Extra Support
  • Z-0915-2022 · Mar 8, 2022 · Open, Classified
    ROTAWIRE Drive and wireClip Torquer, ROTAWIRE Drive Floppy
  • Z-0212-2016 · Oct 9, 2015 · Terminated
    RotaWire Elite and wireClip Torquer, Guidewire and Guidewire Manipulation Device, Extra Support. REF H802233301 (5-pack outer package), REF H802233300 (single unit). The Rota
  • Z-0211-2016 · Oct 9, 2015 · Terminated
    RotaWire Elite and wireClip Torquer, Guidewire and Guidewire Manipulation Device, Floppy. REF H802223301 (5-pack outer package), REF H802223300 (single unit). The Rotablator

Other CATHETER, CORONARY, ATHERECTOMY devices

All CATHETER, CORONARY, ATHERECTOMY devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page