Skip to content

MULTI-LINK MINI VISION 1007821-23Recalls & reported problems

Abbott Vascular Inc. · MULTI-LINK MINI VISION Coronary Stent and Stent Delivery System 2.00 mm x 23 mm / Rapid-Exchange · Class 3 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08717648049415), received between Jun 2, 2017 and Jul 25, 2019 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Device Damaged by Another Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Most reported problems

Device problems

  • Device Damaged by Another Device1
  • Device Dislodged or Dislocated1
  • Difficult to Remove1
  • Failure to Advance1
  • Material Rupture1
  • Physical Resistance1

Patient problems

  • No Consequences Or Impact To Patient2
  • No Patient Involvement1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 25, 2019Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT BEFORE USE, THE STENT OF A 2.0 X 23 MM MINI VISION STENT DELIVERY SYSTEM WAS FOUND DISLODGED INSIDE THE PROTECTIVE SHEATH. ANOTHER 2.0 X 23 MM MINI VISION STENT WAS USED TO SUCCESSFULLY COMPLETE THE PROCEDURE. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Patient Involvement

    MAUDE report 8827479 ↗
  • MalfunctionSep 29, 2017Material Rupture; Physical Resistance

    IT WAS REPORTED THE PROCEDURE WAS TO TREAT A HEAVILY CALCIFIED LESION IN THE LEFT ANTERIOR DESCENDING (LAD) ARTERY. THE 2.0X23 MINI VISION STENT DELIVERY SYSTEM (SDS) WAS ADVANCED TO THE LESION WITH RESISTANCE NOTED DUE TO THE ANATOMY. THE BALLOON APPEARED TO BE RUPTURED DURING ATTEMPTED INITIAL INFLATION. THE DEVICE WAS WITHDRAWN WITH NO ISSUE. THE 2.0X15MM MINI VISION SDS WAS ADVANCED HOWEVER THE STENT STRUTS WERE NOTED TO BE FLARED. THE DEVICE WAS REMOVED WITHOUT ISSUE. THE PROCEDURE WAS COMPLETED WITH ANOTHER MINI VISION SDS. THERE WAS NO CLINICALLY SIGNIFICANT DELAY IN THE PROCEDURE AND NO ADVERSE PATIENT EFFECTS. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6903898 ↗
  • MalfunctionJun 2, 2017Difficult to Remove; Failure to Advance; Device Damaged by Another Device

    IT WAS REPORTED THAT THE PROCEDURE WAS TO TREAT THE PROXIMAL LEFT ANTERIOR DESCENDING ARTERY (LAD). A NON-ABBOTT STENT WAS DEPLOYED SUCCESSFULLY IN THE PROXIMAL LAD. AN ATTEMPT WAS MADE TO CROSS WITH THE 2.0 X 23 MM MINI VISION SDS AND DURING THE ATTEMPT TO CROSS THROUGH THE NON-ABBOTT STENT, THE MINI VISION STENT BECAME CAUGHT ON THE DEPLOYED NON-ABBOTT STENT. THE DEVICES WERE REMOVED FROM THE PATIENT AS ONE UNIT AND AFTER REMOVAL IT WAS OBSERVED THAT THE NON-ABBOTT STENT WAS EXPLANTED. NO ADVERSE PATIENT EFFECTS WERE NOTED; THEREFORE, THE PROCEDURE CONTINUED ON WITH THE SUCCESSFUL DEPLOYMENT OF NON-ABBOTT AND ABBOTT STENTS. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6609287 ↗

Other STENT, CORONARY devices

All STENT, CORONARY devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page