Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08717648050763), received between Sep 1, 2017 and Sep 1, 2017 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device Dislodged or Dislocated1
- Failure to Advance1
- Material Deformation1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 1, 2017Failure to Advance; Device Dislodged or Dislocated; Material Deformation
IT WAS REPORTED THAT THE PROCEDURE WAS TO TREAT A LESION LOCATED IN THE HEAVILY CALCIFIED CIRCUMFLEX (CX) ARTERY. AFTER SUCCESSFUL DEPLOYMENT OF A STENT DISTALLY IN THE CX, A 4.0 X 8 MM MULTI-LINK VISION STENT DELIVERY SYSTEM (SDS) WAS ADVANCED TO DEPLOY A SECOND STENT PROXIMAL TO THE FIRST STENT. DURING ADVANCEMENT IT WAS OBSERVED THAT SDS WAS HAVING DIFFICULTY CROSSING THE HEAVY CALCIFICATION AND A REVIEW OF ANGIOGRAPHY NOTED THE STENT WAS ALSO OBSERVED TO BE TOO SHORT TO COVER THE REMAINING LESION. THE DECISION WAS MADE TO REMOVE THE SDS AND USE A LONGER 4.0 X 12 MM STENT. AFTER RETRACTION OF THE SDS FROM THE ANATOMY IT WAS OBSERVED THAT THE DISTAL END OF THE STENT WAS FLARED AND THAT THE STENT IMPLANT HAD BEEN PUSHED OFF THE BALLOON ONTO THE SHAFT OF THE DELIVERY SYSTEM. THE 4.0 X 12 MM VISION STENT WAS USED SUCCESSFULLY FOR TREATMENT. NO ADVERSE PATIENT EFFECTS OR CLINICALLY SIGNIFICANT DELAY IN THE PROCEDURE WERE REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6838033 ↗
Other STENT, CORONARY devices
- WALLSTENT® Endoprosthesis H965403130Boston Scientific Corporation · STENT, CORONARY35 reports
- WALLSTENT® Endoprosthesis H965402130Boston Scientific Corporation · STENT, CORONARY23 reports
- Tryton Side Branch Stent T5-2530-191-USTryton Medical, Inc. · Stent, Coronary1 death22 reports
- WALLSTENT® Endoprosthesis H965403330Boston Scientific Corporation · STENT, CORONARY21 reports
- WALLSTENT® Endoprosthesis H965403320Boston Scientific Corporation · STENT, CORONARY10 reports
- WALLSTENT® Endoprosthesis H965403120Boston Scientific Corporation · STENT, CORONARY9 reports
- PALMAZ Balloon Expandable Stent P308Cordis US Corp. · STENT, CORONARY7 reports
- Cobra PzF 170-03-35024Celonova Biosciences, Inc. · Stent, Coronary7 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page