Armada A1040-120Recalls & reported problems
Abbott Vascular Inc. · Armada 14 PTA Catheter 4.0 mm x 120 mm x 90 cm / Over-The-Wire · Class 2
All models of Armada (213)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08717648155888), received between Jun 30, 2025 and Jun 30, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Deformation Due to Compressive Stress” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Deformation Due to Compressive Stress1
- Difficult to Advance1
- Material Rupture1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 30, 2025Material Rupture; Deformation Due to Compressive Stress; Difficult to Advance; Material Rupture; Deformation Due to Compressive Stress; Difficult to Advance
IT WAS REPORTED THAT THE PROCEDURE PERFORMED WAS TO TREAT AN OCCLUDED, HEAVILY CALCIFIED, MILDLY TORTUOUS POPLITEAL ARTERY USING A 4GX25CM HI-TORQUE (HT) COMMAND 14 GUIDEWIRE AND A 2.0X20MM ARMADA 14 XT BALLOON DILATATION CATHETER (BDC). THE HT COMMAND GUIDEWIRE AND ARMADA 14 BDC STUCK TOGETHER DURING REMOVAL AND WERE WITHDRAWN AS ONE UNIT. A 4.0X120MM ARMADA 14 PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) BDC WAS TO BE USED IN THE HEAVILY CALCIFIED, MILDLY TORTUOUS LEFT INTERIOR TIBIAL. DURING ADVANCEMENT OF THE ARMADA 14 PTA BDC, RESISTANCE WAS MET DUE TO ANATOMY. ONCE AT THE LESION, THE ARMADA 14 PTA BDC WAS INFLATED ONCE TO 6 ATMOSPHERES AND COLLAPSED ON ITSELF LIKE AN ACCORDION. THE PROCEDURE WAS TERMINATED AND IT IS UNKNOWN IF OTHER DEVICES WERE USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT EFFECTS AND NO CLINICALLY SIGNIFICANT DELAY IN THE PROCEDURE. NO ADDITIONAL INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22362266 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page