Armada A2040-060Recalls & reported problems

Abbott Vascular Inc. · Armada 14 PTA Catheter 4.0 mm x 60 mm x 150 cm / Over-The-Wire · Class 2

All models of Armada (213)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 08717648156144), received between Apr 30, 2019 and Jan 16, 2025 — classified as 7 malfunctions.

The most frequently reported specific device problem is “Material Rupture” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Rupture4
  • Leak/Splash2
  • Deflation Problem1
  • Inflation Problem1
  • Material Separation1
  • Material Split, Cut or Torn1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • No Consequences Or Impact To Patient3

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 16, 2025Inflation Problem; Leak/Splash; Inflation Problem; Leak/Splash

    IT WAS REPORTED THAT THE PROCEDURE WAS TO TREAT A 70% STENOSED LESION IN THE POPLITEAL ARTERY WITH MODERATE CALCIFICATION AND MODERATE TORTUOSITY. AFTER A COMMAND ES GUIDE WIRE (GW) CROSSED THE TARGET LESION, THE 4X60MM ARMADA 14 BALLOON DILATION CATHETER (BDC) WAS ADVANCE TO THE TARGET LESION AND THE BALLOON WAS INFLATED TO NOMINAL PRESSURE; HOWEVER, THE BALLOON COULD NOT BE COMPLETELY INFLATED. THE HUB OF THE BDC WAS THEN NOTED TO HAVE LEAKAGE; THEREFORE, THE BDC WAS REMOVED FROM THE PATIENT. A 4X80MM ARMADA BALLOON WAS USED TO CONTINUE THE PROCEDURE. THERE WAS NO ADVERSE PATIENT EFFECT AND NO CLINICALLY SIGNIFICANT DELAY REPORTED IN THE PROCEDURE. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21170920 ↗
  • MalfunctionJun 8, 2023Leak/Splash; Material Split, Cut or Torn; Leak/Splash; Material Split, Cut or Torn

    IT WAS REPORTED THAT DURING PREPARATION OF AND BEFORE USE IN THE PATIENT, WHEN NEGATIVE PRESSURE WAS PULLED, THERE WAS A LEAK OBSERVED IN THE BALLOON [TEAR/HOLE IN BALLOON] ON A 9X20MM ARMADA 35 BALLOON CATHETER AN A 4.0X60MM ARMADA 14 BALLOON CATHETER. THE SAME ISSUE OCCURRED WITH BOTH BALLOONS. ANOTHER ARMADA WAS USED TO CONTINUE THE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17092162 ↗
  • MalfunctionJul 25, 2022Material Rupture; Material Rupture

    IT WAS REPORTED THAT THE PROCEDURE WAS TO TREAT A PROXIMAL SUPERFICIAL FEMORAL ARTERY (SFA) TO DISTAL POPLITEAL. THE 3.0X60MM ARMADA 18 AND 4.0X60MM ARMADA 14 BALLOON DILATATION CATHETER BOTH RUPTURED. THE ARMADA 14 RUPTURED AT 11 ATMOSPHERES; HOWEVER, BOTH BALLOONS WERE NOTED TO RUPTURE BEFORE REACHING 14 ATMOSPHERES. ANOTHER UNSPECIFIED BALLOON WAS USED TO SUCCESSFULLY COMPLETE THE PROCEDURE. THERE WAS NO ADVERSE PATIENT EFFECT REPORTED AND NO CLINICALLY SIGNIFICANT DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15095354 ↗
  • MalfunctionJun 23, 2021Material Rupture; Material Rupture

    IT WAS REPORTED THAT THE PROCEDURE WAS TO TREAT A RIGHT TIBIAL ARTERY. A 4X200MM ARMADA 18 BALLOON WAS ADVANCED TO THE LESION AND INFLATED ONCE AT 18 ATMOSPHERES (ATMS) WHEN IT RUPTURED. ANOTHER 4X60MM ARMADA 14 BALLOON WAS THEN USED BUT WHEN INFLATED ONCE IT RUPTURED AT ABOUT 4 ATMS. ANOTHER ARMADA WAS USED TO SUCCESSFULLY COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT EFFECTS AND NO CLINICALLY SIGNIFICANT DELAY IN THE PROCEDURE. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12050855 ↗
  • MalfunctionJun 15, 2020Material Rupture; Material Rupture

    IT WAS REPORTED THAT THE PROCEDURE WAS PERFORMED TO TREAT A LESION IN THE HEAVILY CALCIFIED, NON-TORTUOUS, 70% STENOSED SUPERFICIAL FEMORAL ARTERY. A 6X200MM, 3X80MM, & 5.5X200MM ARMADA 18 AS WELL AS A 3X40MM & 4X60MM PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY BALLOON CATHETERS (PTA) WERE ALL ADVANCED, AND THE BALLOONS RUPTURED AT 14 ATMOSPHERES IN THAT ORDER. A NON-ABBOTT BALLOON AND TWO UNSPECIFIED STENTS WERE USED TO SUCCESSFULLY COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT EFFECTS AND NO CLINICALLY SIGNIFICANT DELAY IN THE PROCEDURE. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10153896 ↗
  • MalfunctionJul 30, 2019Deflation Problem; Material Separation; Deflation Problem; Material Separation

    IT WAS REPORTED THAT THIS WAS A PROCEDURE PERFORMED TO TREAT A CHRONIC TOTAL OCCLUSION IN THE SUPERFICIAL FEMORAL ARTERY. THE ARMADA 14 DILATATION CATHETER WAS INFLATED WITHOUT ISSUE; HOWEVER, THE BALLOON ONLY PARTIALLY DEFLATED, BUT WAS ABLE TO BE PULLED BACK INTO THE SHEATH AND REMOVED WITHOUT ISSUE. THE PATIENT WAS OBSERVED FOR APPROXIMATELY 2 HOURS POST PROCEDURE AND NO PATIENT INJURY WAS NOTED. A SECOND ARMADA 14 WAS USED WITHOUT ISSUE. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8843506 ↗
  • MalfunctionApr 30, 2019Material Rupture; Material Rupture

    IT WAS REPORTED THAT THE PROCEDURE WAS TO TREAT A HEAVILY CALCIFIED POPLITEAL ARTERY. A 4.0 X 60 MM ARMADA 14 BALLOON CATHETER WAS USED; HOWEVER, THE BALLOON RUPTURED DURING THE FIRST INFLATION AT 8 ATMOSPHERES DUE TO THE CALCIFIED LESION. AN UNSPECIFIED ARMADA 35 BALLOON CATHETER WAS USED TO SUCCESSFULLY COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT EFFECTS. THERE WAS NO CLINICALLY SIGNIFICANT DELAY IN THE PROCEDURE. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8566189 ↗

Other CATHETER, PERCUTANEOUS devices

All CATHETER, PERCUTANEOUS devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page