XIENCE ALPINE 1145250-18Recalls & reported problems

Abbott Vascular Inc. · XIENCE Alpine Everolimus Eluting Coronary Stent System 2.50 mm x 18 mm / Over-The-Wire · Class 3 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08717648199899), received between Feb 21, 2019 and Feb 21, 2019 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Stenosis1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 21, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT IN (B)(6) 2017, THE PATIENT PRESENTED WITH ISCHEMIC CARDIOMYELOPATHY AND UNDERWENT A CORONARY STENTING PROCEDURE FOR A LESION IN THE PROXIMAL TO MID LEFT ANTERIOR DESCENDING (LAD) CORONARY ARTERY WITH 80-90% STENOSIS. A 2.50 X 18 MM XIENCE ALPINE STENT WAS DEPLOYED IN THE MID LAD AND A 2.75 X 12 MM XIENCE ALPINE STENT WAS DEPLOYED IN THE PROXIMAL TO MID LAD WITHOUT ISSUE. ON (B)(6) 2019, THE PATIENT UNDERWENT FURTHER PERCUTANEOUS CORONARY TRANSLUMINAL ANGIOPLASTY (PTCA) FOR UNSPECIFIED SYMPTOMS. IN STENT RE-STENOSIS OF THE ALPINE STENTS WAS DIAGNOSED BY ANGIOGRAM. A 3.00 X 28 MM XIENCE SIERRA STENT AND A 3.00 X 23 MM XIENCE SIERRA STENT WERE DEPLOYED IN THE PROXIMAL TO MID LAD TO TREAT THE RE-STENOSIS. THE PATIENT WAS REPORTED TO BE WELL POST PROCEDURE AND WAS THEREFORE DISCHARGED; HOWEVER 5 DAYS LATER THE PATIENT DEVELOPED CHEST PAIN AND LOW BLOOD PRESSURE AND WAS RE-ADMITTED (B)(6) 2019). ANGIOGRAM CONFIRMED IN STENT THROMBOSIS AND THE PATIENT WAS TREATED WITH MEDICATION AND ADDITIONAL BALLOON ANGIOPLASTY. A NON-ABBOTT HEART PUMP WAS USED DURING THE PROCEDURE. POST PROCEDURE THE STENTS WERE CONFIRMED TO BE PATENT AND THE PATIENT WAS REPORTED TO BE STABLE IN H

    Patient problems: Stenosis

    MAUDE report 8360396 ↗

Other Coronary drug-eluting stent devices

All Coronary drug-eluting stent devices →

Sources and updates