Cadwell 302875-000Recalls & reported problems

Technomed Engineering B.V. · Disposable Subdermal Needle Electrode 14x0.38mm 2.5m parallel wire 12pairs · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08720791374877), received between Apr 1, 2026 and Apr 1, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1

Patient problems

  • Burn(s)1
  • Foreign Body In Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 1, 2026Break

    TECHNOMED RECEIVED COMPLAINT VIA DISTRIBUTOR CADWELL 10 MARCH 2026 WITH REGARDS TO THE SUBDERMAL NEEDLE PART NUMBER: 302875-000 (NEEDLE, PARALLEL,14X0.38MM (27G) 100IN12PR), EITHER LOT: 103210: THE COMPLAINT IS THAT THE NEEDLE BROKE OFF IN THE PATIENT, REQUIRING AN ADDITIONAL PROCEDURE TO REMOVE IT. THE EVENT DATE WAS TODAY, MARCH 10TH. "WHILE REMOVING NEEDLES AT THE END OF THE CASE, I NOTICED ONE SHARP HAD BROKEN OFF ABOVE THE HUB FROM THE LEFT VL MUSCLE. I CHECKED THE TAPE AND SURROUNDING AREA BUT COULD NOT FIND THE SHARP. I IMMEDIATELY NOTIFIED THE RN AND RESIDENT WHO WAS STILL IN THE ROOM. WE BOTH FELT AROUND THE INSERTION AREA (WHICH ALSO SHOWED TWO BURN MARKS); NEITHER OF US COULD FEEL THE NEEDLE AND WE WERE NOT CERTAIN IT WAS IN THERE. I SUGGESTED WE ASK (B)(6) TO COME BACK IN THE ROOM TO CONFIRM THE SHARP WAS NO LONGER IN THE PATIENT. THE RESIDENT AGREED. FLAT PLATE IMAGES WERE TAKEN AND THE BROKEN SHARP WAS LOCATED. DR. (B)(6) CAME BACK INTO THE OPERATING ROOM AND PERFORMED ANOTHER PROCEDURE TO REMOVED THE SHARP. THIS ENDED UP IN AN ADDITIONAL HOUR OF OPERATING ROOM TIME, ADDITIONAL (B)(6) TIME, ADDITIONAL LOCAL ANESTHETIC, SILVER NITRATE MATCHSTICKS FOR HEMOSTASIS AND TWO

    Patient problems: Burn(s); Foreign Body In Patient

    MAUDE report 24752006 ↗

Other Electrode, Needle devices

All Electrode, Needle devices →