ARC-EX System ARC-EX System - Professional USRecalls & reported problems
ONWARD Medical N.V. · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08720908310002), received between Sep 11, 2026 and Sep 11, 2026 — classified as 1 injury.
The most frequently reported specific device problem is “Off-Label Use” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Off-Label Use1
Patient problems
- Cramp(s) /Muscle Spasm(s)1
- High Blood Pressure/ Hypertension1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 11, 2026Off-Label Use
On (b)(6) 2026, a PT based in the US, contacted ONWARD MEDICAL to report an adverse event involving the ARC-EX in an adult patient with a chronic SCI (T10 AIS C).\The patient had previously used ARC-EX on an outpatient basis several months prior with positive outcomes, notablly a reduction in spasticity as measured by MAS and no adverse events were reported, and was admitted as an in-patient solely for the purpose of completing a two week ARC-EX trial with no other known contributing medical factors. The patient's prescribed spasticity medication (Baclofen and Tizanidine), had been administered as prescribed at the time of the event with adherence confirmed via the in-patient medication adminstration record. \The patient had no prior history of AD. The patient had also been following bowel and bladder management recommendations per the ARC-EX IFU. \On the day of the event the clinical objective was to facillitate management of lower extremity spasticity, which is not an indicated use per the ARC-EX IFU. Therefore, the device was used off-label. \Stimulation was intiated using new unused electrodes at a previsouly succesful T5/T7 active electrode placement, which ahd been considered
Patient problems: Cramp(s) /Muscle Spasm(s); High Blood Pressure/ Hypertension
MAUDE report 50732783 ↗
FDA clearance and classification
The FDA regulates product code SDO (transcutaneous electrical spine stimulator to improve skeletal muscle strength and sensation) under 21 CFR 890.5851 as a Class II device. 21 CFR 890.5851 ↗
Devices of this type normally need 510(k) clearance before sale.
FDA definition of this device type: A transcutaneous electrical spine stimulator to improve skeletal muscle strength and sensation is a device that can be programmed to apply an electrical current via electrodes on a patient's skin over the spine to improve muscle strength and sensation after neurological deficit.
Common questions about the ARC-EX System ARC-EX System - Professional US
Has the ARC-EX System ARC-EX System - Professional US been recalled?
No FDA recall record in our data names this exact device identifier (DI 08720908310002), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the ARC-EX System ARC-EX System - Professional US?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Sep 11, 2026. That report lists device problem “Off-Label Use” (1); patient problems “Cramp(s) /Muscle Spasm(s)” (1) and “High Blood Pressure/ Hypertension” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the ARC-EX System ARC-EX System - Professional US?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the ARC-EX System ARC-EX System - Professional US, and is it still sold?
The FDA's device database lists ONWARD Medical N.V. as the company responsible for it (brand ARC-EX System, model ARC-EX System - Professional US). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page