Pulsar Expandable PLIF System 2210-0941Recalls & reported problems
GS Medical Co., Ltd. · The Pulsar Expandable PLIF Cage devices are designed for restoring the height of the intervertebral space after resection of the disc. The Pulsar Expandable PLIF Cage devices consist of implants in various heights, footprints, and lordotic configurations with architecture designed to accept pre and post packing of bone graft material. The intervertebral body devices are made of titanium alloy (Ti-6AL-4V ELI). The Pulsar Expandable PLIF Cage devices are not radio lucent, but have large windows through the sides that will allow visualization of the placement and subsequent bone fusion. The Expandable PLIF Cage (Posterior Lumbar Interbody Fusion Cage) are designed for segments L2 to S1. · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08800104089626), received between Jul 16, 2025 and Jul 16, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Collapse” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Collapse1
Patient problems
- Failure of Implant1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 16, 2025Collapse; Collapse
[SUPPLIER] HAD A BRIEF DISCUSSION WITH THE SURGEON AND THE REPRESENTATIVE ABOUT THE CAGE COLLAPSING 6 MONTHS POST OP. THE SURGEON EXPLAINED THAT HE IMPLANTED THE EXPANDABLE CAGE, INITIALLY EXPANDED IT AND TORQUED IT OUT, THEN ALLOWED IT TO SIT MOMENTARILY TO BUILD PRESSURE. HE SUBSEQUENTLY RE-ENGAGED TO FURTHER EXPAND AND TORQUE IT IN AN EFFORT TO ACHIEVE ADDITIONAL HEIGHT. THE TORQUEING OF THE CAGE MULTIPLE TIMES WITH DIFFERENT HEIGHTS IS NOT COMPLIANT WITH THE IFU. DURING THE ROUTINE 6 MONTH FOLLOW UP, XRAYS WERE TAKEN AND THE SURGEON SAW THAT THE IMPLANT WAS NO LONGER EXPANDED. THE PATIENT HAD NO CLINICAL SYMPTOMS (PAIN, LOSS OF FUNCTION, INC). THEREFORE, THE SURGEON CONCLUDED NO INTERVENTION WAS REQUIRED.
Patient problems: Failure of Implant
MAUDE report 22519102 ↗
Other Intervertebral Fusion Device With Bone Graft, Lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.