Skip to content

Osstell SmartPeg Type 101Recalls & reported problems

Osstell AB · ISQ Measurement Peg · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 09010522002131), received between May 15, 2025 and May 15, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Output Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Output Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 15, 2025Output Problem; Output Problem

    IT WAS REPORTED SMARTPEGS (TYPE 101, TYPE 102, TYPE 103 AND TYPE 104) HAVE A DIFFERENT BEHAVIOUR THAN OTHER SMARTPEG TYPES. OSSTELL SMARTPEGS ARE INTENDED TO BE USED AS AN ACCESSORY TO OSSTELL INSTRUMENTS FOR MEASURING IMPLANT STABILITY. THE MEASUREMENT RESULTS ARE PRESENTED USING THE ISQ SCALE WHERE A HIGHER VALUE INDICATES A HIGHER LEVEL OF STABILITY. THE FOUR TYPES OF SMARTPEGS (TYPE 101 - TYPE 104) RELATED TO THIS REPORT ARE INTENDED FOR USE ON IMPLANT LEVEL ON TWO SPECIFIC IMPLANT MODELS, AND ON ABUTMENT LEVEL ON TWO SPECIFIC ABUTMENT MODELS COMPATIBLE TO THOSE SPECIFIC IMPLANT MODELS. MEASUREMENT RESULTS ON ABUTMENT-LEVEL NORMALLY DIFFER SLIGHTLY FROM MEASUREMENT RESULTS ON IMPLANT-LEVEL. THE INSTRUCTIONS FOR USE THEREFORE INCLUDES THE RECOMMENDATION TO IDENTIFY THE ISQ DIFFERENCE TO THE MEASUREMENT PERFORMED AT IMPLANT LEVEL, BY TAKING A MEASUREMENT ON THE IMPLANT BEFORE THE ABUTMENT IS ATTACHED AND THEN A SECOND MEASUREMENT ON THE ABUTMENT. MOST COMMONLY THE MEASURED VALUE IS SLIGHTLY LOWER ON ABUTMENT LEVEL THAN ON IMPLANT LEVEL. BUT WITH THE SMARTPEG TYPES RELATED TO THIS REPORT, ABUTMENT-LEVEL MEASUREMENTS RESULT IN A POSITIVE OFFSET COMPARED TO IMPLANT-LEVEL MEASUREMENT

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22025608 ↗

FDA clearance and classification

Cleared through 510(k) K181888 on Aug 22, 2019 (decision: Substantially Equivalent). Submitted by Osstell AB as “Osstell Beacon”. The FDA review took 405 days. FDA record ↗

The FDA regulates product code EKX (handpiece, direct drive, ac-powered) under 21 CFR 872.4200 as a Class I device. 21 CFR 872.4200 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Osstell SmartPeg Type 101

Has the Osstell SmartPeg Type 101 been recalled?

No FDA recall record in our data names this exact device identifier (DI 09010522002131), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Osstell SmartPeg Type 101?

The FDA's MAUDE database lists 1 adverse event report for this device, received on May 15, 2025. That report lists device problem “Output Problem” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Osstell SmartPeg Type 101?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Osstell SmartPeg Type 101 FDA approved?

It was cleared through 510(k) K181888 on Aug 22, 2019. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Osstell SmartPeg Type 101, and is it still sold?

The FDA's device database lists Osstell AB as the company responsible for it (brand Osstell SmartPeg Type 101, model Osstell SmartPeg Type 101). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Handpiece, Direct Drive, Ac-Powered devices

All Handpiece, Direct Drive, Ac-Powered devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page