Fisher & Paykel Healthcare OPT980ERecalls & reported problems

Fisher & Paykel Healthcare Limited · Optiflow Mask Interface Adapter (Single) · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 09420012436948), received between Jan 27, 2021 and Apr 27, 2023 — classified as 7 malfunctions.

The most frequently reported specific device problem is “Break” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Break6
  • Detachment of Device or Device Component2
  • Material Split, Cut or Torn2

Patient problems

  • No Clinical Signs, Symptoms or Conditions7

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 27, 2023Material Split, Cut or Torn; Material Split, Cut or Torn

    A CONSUMER REPORTED THAT THE TUBING OF AN OPT980E OPTIFLOW + MASK INTERFACE ADAPTER WAS FOUND DAMAGED DURING USE. THERE WERE NO REPORTED PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16828558 ↗
  • MalfunctionJan 20, 2022Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    A DISTRIBUTOR IN (B)(4) REPORTED VIA A FISHER & PAYKEL HEALTHCARE (F&P) FIELD REPRESENTATIVE THAT THE TUBING OF AN OPT980E OPTIFLOW + MASK INTERFACE ADAPTER WAS FOUND DAMAGED DURING PATIENT USE. THERE WERE NO REPORTED PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13310192 ↗
  • MalfunctionDec 22, 2021Break; Material Split, Cut or Torn; Material Split, Cut or Torn

    A DISTRIBUTOR REPORTED ON BEHALF OF AN END-USER IN KANSAS, VIA A FISHER & PAYKEL HEALTHCARE (F&P) REPRESENTATIVE, THAT THE TUBING OF FOUR OPT980E OPTIFLOW + MASK INTERFACE ADAPTERS WERE FOUND DAMAGED DURING USE. THERE WERE NO REPORTED PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13066493 ↗
  • MalfunctionSep 12, 2021Break; Detachment of Device or Device Component; Detachment of Device or Device Component

    A DISTRIBUTOR IN CANADA REPORTED VIA A FISHER AND PAYKEL HEALTHCARE (F&P) FIELD REPRESENTATIVE THAT THE TUBING OF AN OPT980E OPTIFLOW + MASK INTERFACE ADAPTOR WAS FOUND DAMAGED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12458024 ↗
  • MalfunctionApr 15, 2021Break

    A DISTRIBUTOR IN CANADA REPORTED VIA A FISHER & PAYKEL HEALTHCARE (F&P) REPRESENTATIVE THAT AN OPT980 MASK INTERFACE ADAPTER BROKE BETWEEN THE TUBING AND CONNECTOR. THERE WAS NO REPORTED PATIENT CONSEQUENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11676207 ↗
  • MalfunctionJan 27, 2021Break

    A DISTRIBUTOR IN CANADA REPORTED, VIA A FISHER & PAYKEL HEALTHCARE (F&P) REPRESENTATIVE, THAT TWO OPT980E OPTIFLOW + MASK INTERFACE ADAPTERS WERE "COMING APART AT THE BASE OF THE TUBING" DURING USE. THERE WERE NO PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11241286 ↗
  • MalfunctionJan 27, 2021Break

    A DISTRIBUTOR IN (B)(4) REPORTED, VIA A FISHER & PAYKEL HEALTHCARE (F&P) REPRESENTATIVE, THAT OPT980 MASK INTERFACE ADAPTERS WERE "COMING APART AT THE BASE OF THE TUBING" DURING USE. THERE WERE NO PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11240994 ↗

Other Humidifier, Respiratory Gas, (Direct Patient Interface) devices