OviTex® 1S F10246-0610PRecalls & reported problems

Aroa Biosurgery Limited · The OviTex® Reinforced Tissue Matrix Device is a sterile reinforced matrix device comprised of non-dermal sourced layers of extracellular matrix (ECM) (ovine (sheep) derived ECM), paired with a minimal suture footprint. OviTex Reinforced Tissue Matrix Device provides an alternative device solution to permanent synthetic, resorbable/bioabsorbable synthetic, and biologic meshes. The device remodels and helps regenerate tissue while reinforcing the repair and providing structural support. Reinforced tissue matrices enhance performance while maintaining compatibility with the body. The OviTex Reinforced Tissue Matrix Device is used for hernia repair and abdominal wall reconstruction. · Class 2 · Implant

All models of OviTex 1S (12)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 09421904065086), received between Jun 24, 2025 and Jan 12, 2026 — classified as 5 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 2 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 2 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem5

Patient problems

  • Erosion5
  • Dysphagia/ Odynophagia2

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 12, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED ON (B)(6) 2025 THAT A PATIENT WAS EXPERIENCING POTENTIAL MESH EROSION FROM A HIATAL HERNIA REPAIR. A REVISION PROCEDURE WAS CONDUCTED ON (B)(6) 2025. UPON ENTERING ABDOMEN VIA ROBOTIC PORTS, THE ORIGINAL DEVICE WAS FOUND AND REMOVED FROM SUPERIOR ASPECT OF STOMACH. IT WAS REPORTED THAT THE PERMANENT SUTURE HAD ERODED INTO SUPERIOR ASPECT OF FUNDOPLICATION. THIS WAS "REMOVED EASILY", STOMACH IRRIGATED WITH SALINE AND REPAIRED WITH RESORBABLE SUTURE. THE RECURRENT HIATAL HERNIA WAS THEN REPAIRED WITH SUTURES AND PLEDGETS.

    Patient problems: Erosion

    MAUDE report 24048331 ↗
  • InjuryJan 8, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED ON 11DEC2025 THAT A PATIENT WAS EXPERIENCING POTENTIAL MESH EROSION FROM A HIATAL HERNIA REPAIR. A REVISION PROCEDURE WAS CONDUCTED ON (B)(6) 2025. UPON ENTERING ABDOMEN VIA ROBOTIC PORTS, THE ORIGINAL DEVICE WAS FOUND AND REMOVED FROM SUPERIOR ASPECT OF STOMACH. IT WAS REPORTED THAT THE PERMANENT SUTURE HAD ERODED INTO SUPERIOR ASPECT OF FUNDOPLICATION. THIS WAS "REMOVED EASILY", STOMACH IRRIGATED WITH SALINE AND REPAIRED WITH RESORBABLE SUTURE. THE RECURRENT HIATAL HERNIA WAS THEN REPAIRED WITH SUTURES AND PLEDGETS.

    Patient problems: Erosion

    MAUDE report 24008981 ↗
  • InjuryOct 30, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT HIATAL HERNIA REPAIR WITH OVITEX 1SP AND THE LINX REFLUX MANAGEMENT SYSTEM ON (B)(6) 2025. THE PATIENT PRESENTED WITH DYSPHAGIA AND RETURNED FOR ENDOSCOPY ON (B)(6) 2025 WHERE POTENTIAL ENTRY INTO THE ESOPHAGUS WAS NOTED. THE SURGEON NOTED THAT THEY PLAN TO PERFORM AN ADDITIONAL ENDOSCOPY TO ADDRESS THE ISSUE.

    Patient problems: Dysphagia/ Odynophagia; Erosion

    MAUDE report 23432855 ↗
  • InjuryOct 17, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT HIATAL HERNIA REPAIR WITH OVITEX 1SP AND THE LINX REFLUX MANAGEMENT SYSTEM ON (B)(6) 2025. THE PATIENT PRESENTED WITH DYSPHAGIA AND RETURNED IN (B)(6) 2025 FOR ENDOSCOPY ON (B)(6) 2025 WHERE POTENTIAL ENTRY INTO THE ESOPHAGUS WAS NOTED. THE SURGEON NOTED THAT THEY PLAN TO PERFORM AN ADDITIONAL ENDOSCOPY TO ADDRESS THE ISSUE.

    Patient problems: Dysphagia/ Odynophagia; Erosion

    MAUDE report 23323099 ↗
  • InjuryJun 24, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT HIATAL HERNIA SURGERY REPAIR REINFORCED WITH OVITEX 1S. APPROXIMATELY 6 MONTHS LATER, THE PATIENT UNDERWENT REOPERATION FOR SUSPECTED POTENTIAL ESOPHAGEAL EROSION. UPON REOPERATION THE SURGEON NOTED A SMALL PIECE OF POLYPROPYLENE SUTURE IN APPOSITION TO THE ESOPHAGUS. THE SUTURE WAS REMOVED WITHOUT INCIDENT AND THE PATIENT HAD NO FURTHER COMPLICATIONS. THE DEVICE WAS REPORTED TO HAVE OTHERWISE BEEN INTEGRATED AND REMODELED.

    Patient problems: Erosion

    MAUDE report 22322602 ↗

Other Mesh, Surgical, Polymeric devices