Skip to content

OviTex® 2S F10248-1012PRecalls & reported problems

Aroa Biosurgery Limited · The OviTex® Reinforced Tissue Matrix Device is a sterile reinforced matrix device comprised of non-dermal sourced layers of extracellular matrix (ECM) (ovine (sheep) derived ECM), paired with a minimal suture footprint. OviTex Reinforced Tissue Matrix Device provides an alternative device solution to permanent synthetic, resorbable/bioabsorbable synthetic, and biologic meshes. The device remodels and helps regenerate tissue while reinforcing the repair and providing structural support. Reinforced tissue matrices enhance performance while maintaining compatibility with the body. The OviTex Reinforced Tissue Matrix Device is used for hernia repair and abdominal wall reconstruction. · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 09421904065161), received between Jul 28, 2025 and Jul 28, 2025 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Abscess1
  • Bacterial Infection1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PATIENT EXPERIENCED CELLULITIS AND FLUID BUILD UP APPROXIMATELY 1.5 YEARS AFTER HERNIA REPAIR WITH OVITEX 2S. THE FLUID WAS POSITIVE FOR E. COLI AND PREVOTELLA AFTER INCISION DRAINAGE. THE FLUID COLLECTION PERSISTED, AND THE SURGEON PERFORMED A RE-OPERATION TO ADDRESS AND REMOVED SOME POLYPROPYLENE SUTURE. NO FURTHER ISSUES WERE REPORTED.

    Patient problems: Abscess; Bacterial Infection

    MAUDE report 22628194 ↗

Other Mesh, Surgical, Polymeric devices

All Mesh, Surgical, Polymeric devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page