Airlife™ Bubble Humidifier with 6 psi Pressure Relief Valve 002006Recalls & reported problems

Vyaire Medical, Inc. · AirLife™ Bubble Humidifier With 6 psi Pressure Relief Valve · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10190752114791), received between May 3, 2021 and Jan 2, 2024 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Defective Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Defective Device1
  • Device Handling Problem1
  • Obstruction of Flow1

Patient problems

  • Low Oxygen Saturation2
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 2, 2024Device Handling Problem; Device Handling Problem

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE 002006 HUMIDIFIER EMPTY 6 PSI BLUE CAP 50/CS WAS INCORRECTLY CONNECTED TO THE HEATER OF A VENTILATOR.AT THIS TIME, THERE IS NO INFORMATION REGARDING PATIENT INVOLVEMENT ASSOCIATED WITH THE REPORTED EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18428419 ↗
  • InjuryDec 19, 2023Obstruction of Flow; Obstruction of Flow

    IT WAS REPORTED TO VYAIRE MEDICAL THAT AFTER ATTEMPTING TO PLACE A PATIENT ON AN INTERMEDIATE FLOW NASAL CANNULA (12 LPM).THE PATIENT DESATURATED TO 77% SPO2. IT WAS DISCOVERED THAT THE 002006 HUMIDIFIER EMPTY 6 PSI BLUE CAP 50/CS HAD NO HOLE PRESENT ON THE 02 FLOW OUTLET. THE RESPIRATORY THERAPIST THEN PLACED THE PATIENT ON HFNC (HIGH FLOW NASAL CANNULA) AT 50% 02. AT THIS TIME, THE CUSTOMER HAS NOT PROVIDED ANY INFORMATION REGARDING PATIENT HARM OR INJURY ASSOCIATED WITH THE REPORTED EVENT.

    Patient problems: Low Oxygen Saturation

    MAUDE report 18360566 ↗
  • InjuryMay 3, 2021Defective Device; Defective Device

    THE CUSTOMER REPORTED THAT THE AIRLIFE¿ BUBBLE HUMIDIFIER WITH 6 PSI PRESSURE RELIEF VALVE EXPERIENCED FLOW ISSUE THAT RESULTED TO PATIENT DESATURATION. AS AN INTERVENTION, BOTH CANNULA AND BOTTLE WERE CHANGED.

    Patient problems: Low Oxygen Saturation

    MAUDE report 11766705 ↗