AirLife™ 002003Recalls & reported problems
Vyaire Medical, Inc. · AirLife™ Bubble Humidifier With 3 psi Pressure Relief Valve · Class 2
All models of AirLife (25)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10190752115200), received between Mar 5, 2024 and Mar 5, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Partial Blockage” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Partial Blockage1
Patient problems
- Decreased Respiratory Rate1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 5, 2024Partial Blockage; Partial Blockage
CANNISTER HAS PROBLEMS WITH THE POROUS STONE BECOMING BLOCKED AND THE PATIENT NOT GETTING FLOW. PATIENT NOT GETTING FLOW.
Patient problems: Decreased Respiratory Rate
MAUDE report 18843069 ↗
FDA clearance and classification
The FDA regulates product code BTT (humidifier, respiratory gas, (direct patient interface)) under 21 CFR 868.5450 as a Class II device. 21 CFR 868.5450 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the AirLife™ 002003
Has the AirLife™ 002003 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10190752115200), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the AirLife™ 002003?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 5, 2024. That report lists device problem “Partial Blockage” (1); patient problem “Decreased Respiratory Rate” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the AirLife™ 002003?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the AirLife™ 002003, and is it still sold?
The FDA's device database lists Vyaire Medical, Inc. as the company responsible for it (brand AirLife™, model 002003). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other HUMIDIFIER, RESPIRATORY GAS, (DIRECT PATIENT INTERFACE) devices
- Fisher & Paykel Healthcare PT101USFisher & Paykel Healthcare Limited · Humidifier, Respiratory Gas, (Direct Patient Interface)2 recalls5 deaths1,066 reports
- HUDSON RCI IPN913776Teleflex Incorporated · HUMIDIFIER, RESPIRATORY GAS, (DIRECT PATIENT INTERFACE)436 reports
- F&P Optiflow+ OPT944Fisher & Paykel Healthcare Limited · Humidifier, Respiratory Gas, (Direct Patient Interface)5 deaths390 reports
- Fisher & Paykel Healthcare PT100USFisher & Paykel Healthcare Limited · Humidifier, Respiratory Gas, (Direct Patient Interface)2 recalls59 reports
- MR850 MR850JHUFisher & Paykel Healthcare Limited · Humidifier, Respiratory Gas, (Direct Patient Interface)93 reports
- F&P Optiflow Junior 2 OJR412Fisher & Paykel Healthcare Limited · Humidifier, Respiratory Gas, (Direct Patient Interface)79 reports
- F&P Airvo 900PT561Fisher & Paykel Healthcare Limited · Humidifier, Respiratory Gas, (Direct Patient Interface)1 death56 reports
- HUDSON RCI IPN913728Teleflex Incorporated · HUMIDIFIER, RESPIRATORY GAS, (DIRECT PATIENT INTERFACE)1 recall4 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page