Medline Industries, Inc. DYNDH1487ARecalls & reported problems
Medline Industries, Inc. · BLOOD CULTURE KIT 2 W/CONNECT · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
3 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 0
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 3
Summary
No MAUDE adverse event reports in our data reference this device identifier directly.
3 FDA recall records name this device's identifier, 3 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Aug 11, 2026Class IOpen, Classified
The kits contain certain lots of sterile applicators which may contain fungal contamination that may occur under certain environmental conditions, allowing the growth of Aspergillus penicillioides. Contamination of skin preparation products with Aspergillus penicillioides may lead to serious adverse health consequences, including systemic infection, sepsis, illness, and death.
Z-3126-2026 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗
- Jul 20, 2026Class IIOpen, Classified
Downstream recall - manufacturer recalled specific lots of BD ChloraPrep Clear - 1mL Applicators. Affected product may exhibit an open or incomplete seal on the packaging of the applicator. Use of potentially contaminated applicator may lead to localized skin or soft tissue infection, or systemic infection or infectious complications.
Z-3072-2026 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗
- Jun 12, 2026Class IIOpen, Classified
The kits contain BD ChloraPrep Clear - 1 mL and FREPP Clear 1.5 mL Applicators which have a potential breach of sterility in the packaging, due to wrinkles in the paper lidding which may extend to the seal area. If the sterile barrier is compromised, patients and users may be exposed to microbial contamination. Potential health consequences may include no injury, localized infection, or, less commonly, more serious infection requiring medical treatment, antimicrobial therapy, procedural intervention, or hospitalization. In rare cases, particularly in critically ill or immunocompromised patients, severe infection could become life-threatening.
Z-3057-2026 · Root cause: Nonconforming Material/Component · Recall details · FDA record ↗
Other Wound dressing kit devices
- Medline Industries, Inc. DM1035Medline Industries, Inc. · Wound dressing kit2 recalls0 reports
- Medline Industries, Inc. DYNDH1193Medline Industries, Inc. · Wound dressing kit2 recalls0 reports
- Medline Industries, Inc. DYKMBNDL43Medline Industries, Inc. · Wound dressing kit2 recalls0 reports
- Medline Industries, Inc. DYNDH1561Medline Industries, Inc. · Wound dressing kit2 recalls0 reports
- Medline Industries, Inc. SUT13535Medline Industries, Inc. · Wound dressing kit2 recalls0 reports
- Medline Industries, Inc. DYNJ47717AMedline Industries, Inc. · Wound dressing kit2 recalls0 reports
- Medline Industries, Inc. DYNDC2733Medline Industries, Inc. · Wound dressing kit1 recall0 reports
- Medline Industries, Inc. DYNDV2385Medline Industries, Inc. · Wound dressing kit1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page