Medline Industries, Inc. DYNJ43495ARecalls & reported problems
Medline Industries, Inc. · ENDO SINUS PACK · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 0
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
No MAUDE adverse event reports in our data reference this device identifier directly.
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Mar 19, 2026Class IIOpen, Classified
During an internal review, Medline identified higher-than-expected endotoxin levels on a representative Medline neuro sponge product, indicating that in-market product may be out-of-specification for endotoxin.
Z-2021-2026 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Other Ear, nose, and throat surgical tray devices
- Medline Industries, Inc. DYNJ45175BMedline Industries, Inc. · Ear, nose, and throat surgical tray5 recalls0 reports
- Medline Industries, Inc. DYNJ0101278FMedline Industries, Inc. · Ear, nose, and throat surgical tray4 recalls0 reports
- Medline Industries, Inc. DYNJ905866Medline Industries, Inc. · Ear, nose, and throat surgical tray4 recalls0 reports
- Medline Industries, Inc. DYNJ27320VMedline Industries, Inc. · Ear, nose, and throat surgical tray4 recalls0 reports
- Medline Industries, Inc. DYNJ17005IMedline Industries, Inc. · Ear, nose, and throat surgical tray4 recalls0 reports
- Medline Industries, Inc. DYNJ51934AMedline Industries, Inc. · Ear, nose, and throat surgical tray4 recalls0 reports
- Medline Industries, Inc. DYNJ66509AMedline Industries, Inc. · Ear, nose, and throat surgical tray3 recalls1 report
- Medline Industries, Inc. CDS984899GMedline Industries, Inc. · Ear, nose, and throat surgical tray3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page