Medline Industries, Inc. DYNJ35967IRecalls & reported problems
Medline Industries, Inc. · TONSIL PACK 9128194 · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10195327106669), received between Sep 22, 2026 and Sep 22, 2026.
The most frequently reported specific device problem is “Tear, Rip or Hole in Device Packaging” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Tear, Rip or Hole in Device Packaging1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
OtherSep 22, 2026Tear, Rip or Hole in Device Packaging
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50856486 ↗
Other Ear, nose, and throat surgical tray devices
- Medline Industries, Inc. DYNJ45175BMedline Industries, Inc. · Ear, nose, and throat surgical tray5 recalls0 reports
- Medline Industries, Inc. DYNJ0101278FMedline Industries, Inc. · Ear, nose, and throat surgical tray4 recalls0 reports
- Medline Industries, Inc. DYNJ905866Medline Industries, Inc. · Ear, nose, and throat surgical tray4 recalls0 reports
- Medline Industries, Inc. DYNJ27320VMedline Industries, Inc. · Ear, nose, and throat surgical tray4 recalls0 reports
- Medline Industries, Inc. DYNJ17005IMedline Industries, Inc. · Ear, nose, and throat surgical tray4 recalls0 reports
- Medline Industries, Inc. DYNJ51934AMedline Industries, Inc. · Ear, nose, and throat surgical tray4 recalls0 reports
- Medline Industries, Inc. DYNJ66509AMedline Industries, Inc. · Ear, nose, and throat surgical tray3 recalls1 report
- Medline Industries, Inc. CDS984899GMedline Industries, Inc. · Ear, nose, and throat surgical tray3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page