Medline Industries, Inc. DYNJ67250BRecalls & reported problems
Medline Industries, Inc. · GENERAL LAPAROSCOPY PACK · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10195327292232), received between Aug 13, 2026 and Aug 13, 2026 — classified as 1 malfunction.
The most frequently reported specific device problem is “Decoupling” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Decoupling1
- Melted1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 13, 2026Decoupling; Melted
It was reported that "Customer having issues with bovie cords, might be monopolar. A cord melted and burned a surgeons hand."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50236066 ↗
Other laparoscopy kit devices
- Medline Industries, Inc. DYNJ82871Medline Industries, Inc. · laparoscopy kit5 recalls0 reports
- Medline Industries, Inc. CDS860015WMedline Industries, Inc. · laparoscopy kit4 recalls0 reports
- Medline Industries, Inc. CDS860016RMedline Industries, Inc. · laparoscopy kit4 recalls0 reports
- Medline Industries, Inc. DYNJ0426069NMedline Industries, Inc. · laparoscopy kit4 recalls0 reports
- Medline Industries, Inc. DYNJ905071FMedline Industries, Inc. · laparoscopy kit4 recalls0 reports
- Medline Industries, Inc. DYNJ52656BMedline Industries, Inc. · laparoscopy kit4 recalls0 reports
- Medline Industries, Inc. DYNJ21927RMedline Industries, Inc. · laparoscopy kit4 recalls0 reports
- Medline Industries, Inc. DYNJ58561DMedline Industries, Inc. · laparoscopy kit3 recalls1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page