Jelco 3055Recalls & reported problems

Icu Medical, Inc. · GTIN for PRO 18 X 1 1/4 Each · Class 2

All models of Jelco (101)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
18
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 18 adverse event reports that list this exact device (DI 10351688071095), received between Oct 3, 2017 and May 28, 2025 — classified as 6 injuries, 12 malfunctions.

The most frequently reported specific device problem is “Leak/Splash” (8 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Leak/Splash8
  • Detachment of Device or Device Component4
  • Break3
  • Disconnection2
  • Device-Device Incompatibility1
  • Difficult to Remove1
  • Material Deformation1
  • Material Fragmentation1

Patient problems

  • No Consequences Or Impact To Patient8
  • Foreign Body In Patient5
  • No Clinical Signs, Symptoms or Conditions3
  • No Known Impact Or Consequence To Patient2
  • Distress1

Recent adverse event reports

The 18 most recent of 18 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 28, 2025Break; Disconnection; Break; Disconnection

    IT WAS REPORTED THAT CATHETER TIP WAS NOT PRESENT UPON REMOVAL FROM PATIENT¿S ARM AT TIME OF DISCHARGE. STAFF THOUGHT THAT THE CATHETER BROKE OFF FROM HUB IN TWO DIFFERENT PATIENTS. THERE WAS A PATIENT INVOLVEMENT AND NO PATIENT OR CLINICIAN INJURY. AFTER THE IV CATHETER WAS VISUALIZED IN THE PATIENT¿S ARM, THE VASCULAR TEAM WAS CONSULTED TO REMOVE IT FROM THE PATIENT¿S VEIN. THE PATIENT WAS TAKEN TO THE OPERATING ROOM, AND A CEPHALIC VEIN LIGATION WAS PERFORMED. THE PATIENT REMAINED IN THE HOSPITAL AFTER SURGERY AN ADDITIONAL DAY AND WAS DISCHARGED ON (B)(6) 2025.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22096473 ↗
  • MalfunctionMay 16, 2024Disconnection; Device-Device Incompatibility; Disconnection; Device-Device Incompatibility

    IT WAS REPORTED THAT THE CUSTOMER NEEDS TO TEST THE COMPATIBILITY OR MATING OF THE CATHETERS TO THEIR ITEM NUMBER. IT ALSO STATED THAT THEIR CUSTOMER IS SAYING THAT THE EXTENSION SET AND/OR MALE LUER POPS OFF THE CATHETER FEMALE LUER DURING CT INJECTION. THIS IS INTERMITTENT, BUT THEY HAVE SEEN AN INCREASE. THEY WANT TO VERIFY THAT ALL ITEMS ARE IN SPEC AND VALIDATE UNDER HIGH PRESSURE INJECTION. THERE WAS PATIENT INVOLVEMENT AND UNKNOWN PATIENT HARM/ADVERSE EVENT REPORTED. DATE OF EVENT WAS IN MARCH/APRIL STILL ON GOING. THE EVENT OCCURS AT CT. AFFECTED QUANTITY REPORTED AS 2.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19330938 ↗
  • MalfunctionMay 8, 2023Mechanical Problem; Mechanical Problem

    IT WAS REPORTED THAT THE DEVICE SHEAR WHEN WITHDRAWING THE INTRAVENOUS (IV).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16885306 ↗
  • InjuryJun 30, 2022Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED PER MEDWATCH (B)(4): UPON ASSESSMENT OF PIV, IT WAS NOTED THAT CATHETER WAS MISSING. SITE ASSESSED AND FELT AS IF CATHETER WAS STILL IN PATIENTS ARM. ULTRASOUND CONFIRMED IV CATHETER RETENTION. A CLINICAL DECISION MADE NOTING THE BENEFIT OF REMOVING THE FOREIGN BODY DID NOT OUTWEIGH THE RISK.

    Patient problems: Distress; Foreign Body In Patient

    MAUDE report 14875672 ↗
  • MalfunctionMay 26, 2022Difficult to Remove; Detachment of Device or Device Component

    UPON ASSESSMENT OF PIV, IT WAS NOTED THAT CATHETER WAS MISSING. SITE ASSESSED AND FELT AS IF CATHETER WAS STILL IN PATIENTS ARM. ULTRASOUND CONFIRMED IV CATHETER RETENTION. CLINICAL DECISION MADE NOTING THE BENEFIT OF REMOVING THE FOREIGN BODY DID NOT OUTWEIGH THE RISK.

    Patient problems: Foreign Body In Patient

    MAUDE report 14512288 ↗
  • InjuryMar 25, 2022Break; Break

    IT WAS REPORTED THAT DURING THE REMOVAL OF THE CATHETER, PRIOR TO DISCHARGE, THE NURSE NOTICED THAT AFTER SHE PULLED THE HUB BACK ONLY ABOUT 2MM (1/16") OF THE CATHETER REMAINED ON THE HUB. THE REMAINING 1 3/16" OF THE CATHETER REMAINED WITHIN THE PATIENT. AFTER AN X-RAY WAS OBTAINED THE RADIOLOGIST REPORTED THAT; "THERE IS AN IV CATHETER INVOLVING THE SOFT TISSUES OF THE MEDIAL ASPECT OF THE RIGHT ELBOW." THE CATHETER WAS REMOVED BY THE GENERAL SURGEON, RESOLVING THE REPORTED EVENT.

    Patient problems: Foreign Body In Patient

    MAUDE report 13905143 ↗
  • InjuryJul 9, 2021Detachment of Device or Device Component; Detachment of Device or Device Component

    INFORMATION RECEIVED A SMITHS MEDICAL PERIPHERAL INTRAVENOUS CATHETERS (PIVC)/JELCO SAFETY PROTECTIV CATHETERS BROKE OFF DURING IV ATTEMPT. IV HAD TO BE SURGICALLY REMOVED FROM PATIENTS ARM BY EMERGENCY ROOM "DEPORTMENT" MD.

    Patient problems: Foreign Body In Patient

    MAUDE report 12147783 ↗
  • InjuryJul 9, 2021Detachment of Device or Device Component; Detachment of Device or Device Component

    INFORMATION RECEIVED A SMITHS MEDICAL PERIPHERAL INTRAVENOUS CATHETERS (PIVC)/JELCO SAFETY PROTECTIV CATHETERS BROKE OFF DURING IV ATTEMPT. IV HAD TO BE SURGICALLY REMOVED FROM PATIENTS ARM BY ER DEPORTMENT MD.

    Patient problems: Foreign Body In Patient

    MAUDE report 12147717 ↗
  • MalfunctionAug 1, 2018Use of Device Problem; Use of Device Problem

    IT WAS REPORTED THAT THE NURSING STAFF WAS HAVING GREAT DIFFICULTY GETTING THE BLOOD TO DRAW WITH THE JELCO SAFETY PROTECTIV CATHETER. NO DEATH OR SERIOUS INJURY WAS REPORTED IN CONNECTION WITH THIS INCIDENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7740933 ↗
  • InjuryDec 27, 2017Break; Material Fragmentation; Material Deformation; Break; Material Fragmentation; Material Deformation

    INFORMATION WAS RECEIVED INDICATING THAT A SMITHS MEDICAL JELCO® PROTECTIV® SAFETY I.V. CATHETER BROKE OFF AND REMAINED IN THE PATIENT. SIX HOURS FOLLOWING, THE SEVERED CATHETER WAS RETRIEVED. THE PATIENT RECOVERED WITH NO ADVERSE EFFECTS.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7147776 ↗
  • MalfunctionOct 3, 2017Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT A SMITHS MEDICAL JELCO®PROTECTIV® SAFETY I.V. CATHETER HAD "GUSHED" BLOOD OUT OF THE FLASH CHAMBER AND ONTO THE SKIN. THE CATHETER WAS NOTED TO BE THREADED TO SKIN LINE WITH FULL NEEDLE RETRACTION AND LOCK OUT WHEN THE BLOOD "GUSHED" PASS THE FLASH CHAMBER AND WENT INTO THE HOUSING UNIT. THE CATHETER WAS REMOVED AND A NEW ONE WAS PLACED WITH NO REPORTED ADVERSE PATIENT EFFECTS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6912308 ↗
  • MalfunctionOct 3, 2017Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT A SMITHS MEDICAL JELCO®PROTECTIV® SAFETY I.V. CATHETER HAD "GUSHED" BLOOD OUT OF THE FLASH CHAMBER AND ONTO THE SKIN. THE CATHETER WAS NOTED TO BE THREADED TO SKIN LINE WITH FULL NEEDLE RETRACTION AND LOCK OUT WHEN THE BLOOD "GUSHED" PASS THE FLASH CHAMBER AND WENT INTO THE HOUSING UNIT. THE CATHETER WAS REMOVED AND A NEW ONE WAS PLACED WITH NO REPORTED ADVERSE PATIENT EFFECTS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6912293 ↗
  • MalfunctionOct 3, 2017Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT A SMITHS MEDICAL JELCO®PROTECTIV® SAFETY I.V. CATHETER HAD "GUSHED" BLOOD OUT OF THE FLASH CHAMBER AND ONTO THE SKIN. THE CATHETER WAS NOTED TO BE THREADED TO SKIN LINE WITH FULL NEEDLE RETRACTION AND LOCK OUT WHEN THE BLOOD "GUSHED" PASS THE FLASH CHAMBER AND WENT INTO THE HOUSING UNIT. THE CATHETER WAS REMOVED AND A NEW ONE WAS PLACED WITH NO REPORTED ADVERSE PATIENT EFFECTS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6912265 ↗
  • MalfunctionOct 3, 2017Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT A SMITHS MEDICAL JELCO®PROTECTIV® SAFETY I.V. CATHETER HAD "GUSHED" BLOOD OUT OF THE FLASH CHAMBER AND ONTO THE SKIN. THE CATHETER WAS NOTED TO BE THREADED TO SKIN LINE WITH FULL NEEDLE RETRACTION AND LOCK OUT WHEN THE BLOOD "GUSHED" PASS THE FLASH CHAMBER AND WENT INTO THE HOUSING UNIT. THE CATHETER WAS REMOVED AND A NEW ONE WAS PLACED WITH NO REPORTED ADVERSE PATIENT EFFECTS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6912262 ↗
  • MalfunctionOct 3, 2017Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT A SMITHS MEDICAL JELCO®PROTECTIV® SAFETY I.V. CATHETER HAD "GUSHED" BLOOD OUT OF THE FLASH CHAMBER AND ONTO THE SKIN. THE CATHETER WAS NOTED TO BE THREADED TO SKIN LINE WITH FULL NEEDLE RETRACTION AND LOCK OUT WHEN THE BLOOD "GUSHED" PASS THE FLASH CHAMBER AND WENT INTO THE HOUSING UNIT. THE CATHETER WAS REMOVED AND A NEW ONE WAS PLACED WITH NO REPORTED ADVERSE PATIENT EFFECTS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6912255 ↗
  • MalfunctionOct 3, 2017Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT A SMITHS MEDICAL JELCO®PROTECTIV® SAFETY I.V. CATHETER HAD "GUSHED" BLOOD OUT OF THE FLASH CHAMBER AND ONTO THE SKIN. THE CATHETER WAS NOTED TO BE THREADED TO SKIN LINE WITH FULL NEEDLE RETRACTION AND LOCK OUT WHEN THE BLOOD "GUSHED" PASS THE FLASH CHAMBER AND WENT INTO THE HOUSING UNIT. THE CATHETER WAS REMOVED AND A NEW ONE WAS PLACED WITH NO REPORTED ADVERSE PATIENT EFFECTS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6912239 ↗
  • MalfunctionOct 3, 2017Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT A SMITHS MEDICAL JELCO®PROTECTIV® SAFETY I.V. CATHETER HAD "GUSHED" BLOOD OUT OF THE FLASH CHAMBER AND ONTO THE SKIN. THE CATHETER WAS NOTED TO BE THREADED TO SKIN LINE WITH FULL NEEDLE RETRACTION AND LOCK OUT WHEN THE BLOOD "GUSHED" PASS THE FLASH CHAMBER AND WENT INTO THE HOUSING UNIT. THE CATHETER WAS REMOVED AND A NEW ONE WAS PLACED WITH NO REPORTED ADVERSE PATIENT EFFECTS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6912217 ↗
  • MalfunctionOct 3, 2017Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT A SMITHS MEDICAL JELCO®PROTECTIV® SAFETY I.V. CATHETER HAD "GUSHED" BLOOD OUT OF THE FLASH CHAMBER AND ONTO THE SKIN. THE CATHETER WAS NOTED TO BE THREADED TO SKIN LINE WITH FULL NEEDLE RETRACTION AND LOCK OUT WHEN THE BLOOD "GUSHED" PASS THE FLASH CHAMBER AND WENT INTO THE HOUSING UNIT. THE CATHETER WAS REMOVED AND A NEW ONE WAS PLACED WITH NO REPORTED ADVERSE PATIENT EFFECTS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6912215 ↗

Other Catheter,intravascular,therapeutic,short-term less than 30 days devices

All Catheter,intravascular,therapeutic,short-term less than 30 days devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page