OSV II® 909712Recalls & reported problems

Integra LifeSciences Switzerland Sàrl · OSV II® Valve System WITH ANTECHAMBER AND SEPARATE 15CM VENTRICULAR CATHETER · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10381780034032), received between Nov 19, 2021 and May 1, 2026 — classified as 3 injuries, 1 malfunction.

The most frequently reported specific device problem is “Complete Blockage” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Complete Blockage1
  • Crack1
  • Fluid/Blood Leak1
  • Infusion or Flow Problem1
  • Material Split, Cut or Torn1
  • Material Too Soft/Flexible1

Patient problems

  • Cerebrospinal Fluid Leakage1
  • No Clinical Signs, Symptoms or Conditions1
  • Obstruction/Occlusion1
  • Visual Disturbances1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 1, 2026Material Too Soft/Flexible; Material Split, Cut or Torn

    A FACILITY REPORTED THAT DURING VENTRICULOPERITONEAL (VP) SHUNT IMPLANTATION FOR HYDROCEPHALUS PROCEDURE, TUNNELING FOR THE PLACEMENT OF THE DISTAL (PERITONEAL) CATHETER WAS PERFORMED WITHOUT COMPLICATIONS. AFTER IMPLANTING THE VENTRICULAR CATHETER INTO THE CEREBRAL VENTRICLE, AT THE TIME OF CONNECTING THE VENTRICULAR CATHETER TO THE VALVE, THE SURGICAL TEAM OBSERVED THAT THE CATHETER PRESENTED A PERFORATION/TEAR AT THE CONNECTION SITE. THE DAMAGED SEGMENT WAS CUT, AND THE CONNECTION ATTEMPT WAS REPEATED; HOWEVER, THE SAME ISSUE OCCURRED THREE CONSECUTIVE TIMES. PROPER COUPLING WAS ONLY ACHIEVED AFTER EXTREMELY DELICATE HANDLING. IN THE NEXT STEP, WHEN POSITIONING THE VALVE IN THE LATERAL POCKET OF THE PATIENT¿S HEAD, THE DEVICE PRESENTED BILATERAL OPENING, WITH THE ONSET OF CEREBROSPINAL FLUID LEAKAGE. ACCORDING TO THE TEAM¿S REPORT, THE MATERIAL APPEARED MORE FRAGILE THAN USUAL, RESEMBLING A DRIED OR BRITTLE CONDITION, BECOMING DAMAGED EVEN UNDER CAREFUL HANDLING AND WITHIN STANDARD TECHNIQUE. THE ISSUE WITH THE PRODUCT DELAYED THE PROCEDURE BY APPROXIMATELY 30 MINUTES; HOWEVER, THERE WAS NO INJURY TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25061728 ↗
  • InjuryAug 29, 2024Crack; Fluid/Blood Leak; Crack; Fluid/Blood Leak

    N/A.

    Patient problems: Cerebrospinal Fluid Leakage

    MAUDE report 20103737 ↗
  • InjuryJun 13, 2022Complete Blockage; Complete Blockage

    A FACILITY REPORTED THAT THE OSV II VALVE (909712) WAS NOT DRAINING AND THE PATIENT WAS STARTING TO GO BLIND FROM BOTH EYES. FURTHER INFORMATION RECEIVED INDICATES THAT THE VALVE WAS EXPLANTED DUE TO IT BEING BLOCKED, AND THE INCREASED ICP (INTRACRANIAL PRESSURE) LED TO WEAKENED OPTIC NERVES AND IMPACTED VISION. NO ADDITIONAL INFORMATION HAS BEEN MADE AVAILABLE.

    Patient problems: Visual Disturbances

    MAUDE report 14674988 ↗
  • InjuryNov 19, 2021Infusion or Flow Problem; Infusion or Flow Problem

    N/A

    Patient problems: Obstruction/Occlusion

    MAUDE report 12845043 ↗

Other Shunt, central nervous system and components devices

All Shunt, central nervous system and components devices →