Skip to content

CUSA® Excel C2601Recalls & reported problems

Integra Lifesciences (Ireland) Limited · CUSA® Excel CUSA® Excel 23kKHz Angled Handpiece · Class U

All models of CUSA Excel (14)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10381780039426), received between Jan 2, 2024 and May 14, 2025 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Energy Output Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Energy Output Problem1
  • Fracture1
  • Overheating of Device1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Burn(s)1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 14, 2025Overheating of Device; Overheating of Device

    N/A.

    Patient problems: Burn(s)

    MAUDE report 22018659 ↗
  • MalfunctionMar 27, 2025Energy Output Problem; Energy Output Problem

    A FACILITY REPORTED THAT PRIOR TO AN UNSPECIFIED SURGERY, THE CUSA EXCEL 23KHZ ANGLED HANDPIECE (C2601) WAS DEFECTIVE. THE EXACT DEVICE MALFUNCTION IS NOT KNOWN, BUT THE PATIENT WAS PREPARED/UNDER ANESTHESIA AT THE TIME, THERE WAS INCREASED SURGICAL TIME AS A RESULT. THE HANDPIECE WAS USED WITH AN OLD CONSOLE CUSA EXCEL8, WHICH IS NOT REPAIRABLE. ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER: "THE SURGEON DOES NOT WANT TO ANSWER THE QUESTIONS "YOUR SALES REP INFORMS ME THAT NO REPAIR IS POSSIBLE ON OUR DEVICE BECAUSE YOU HAVE DECLARED IT OBSOLETE. YOUR QUESTIONS ARE THEREFORE IRRELEVANT." THE SURGEON DOES NOT WANT TO ANSWER THE QUESTIONS."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21708694 ↗
  • MalfunctionJan 2, 2024Fracture; Fracture

    N/A.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18427362 ↗

Other Device, neurosurgical fragmentation and aspiration devices

All Device, neurosurgical fragmentation and aspiration devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page