Skip to content

Integra® INS030Recalls & reported problems

Integra Pain Management · Integra® Hand Drill - Sterile

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10381780263890), received between Aug 21, 2024 and Aug 21, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device-Device Incompatibility1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 21, 2024Device-Device Incompatibility; Device-Device Incompatibility

    A FACILITY REPORTED THAT DURING NEUROSURGERY, AT THE END OF PROCEDURE, IT WAS NOTICED THAT ONE SCREW WAS COMING OUT FROM THE "HAND DRILL: STERILE (INS030)", DESPITE A PROPER FIXATION. THE PATIENT DID NOT HAVE ANY CLINICAL CONSEQUENCES (DESPITE THE RISK OF LOSING CONTROL OF THE INSTRUMENT THAT COULD HAVE LED TO CRANIAL BLOOD LOSS). ADDITIONAL INFORMATION RECEIVED AS FOLLOWS: DESCRIPTION: THE DRILL BIT COMES OUT OF THE HAND DRILL BECAUSE IT WAS NOT HELD PROPERLY DESPITE PROPER PLACEMENT. WHICH TYPE OF DRILL BIT WAS USED WITH INS030? DRILL BIT CONTAINED IN THE SOPHYSA KIT (PRESSIO, NOT INTEGRA PRODUCT) REFERENCE AND LOT NUMBER IF KNOWN? PSO-PB (PRESSIO® ICP MONITORING KIT, PARENCHYMAL WITH BOLT), LOT UNKNOWN. NOT INTEGRA PRODUCT. DRILL BIT DIAMETER? 2.7MM. WHICH PROCEDURE: IMPLANT OF INTRACRANIAL PRESSURE SENSOR. DID IT LEAD TO ANY INCREASE OF SURGERY TIME? ABOUT 3 MINUTES FOR A PROCEDURE WHICH USUALLY TAKES 15 MIN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20013563 ↗

Sources and updates