CODMAN® 823045Recalls & reported problems
Integra Lifesciences Production Corporation · CODMAN® Peritoneal Catheter · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 13
- Deaths reported
- 0
- Injuries reported
- 13
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 13 adverse event reports that list this exact device (DI 10381780518839), received between Sep 12, 2023 and Feb 6, 2026 — classified as 13 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Insufficient Device Problem Information5
- Fluid/Blood Leak3
- Obstruction of Flow3
- Infusion or Flow Problem1
- Leak/Splash1
- Migration1
Patient problems
- Insufficient Information8
- Cerebral Ventriculomegaly3
- Ambulation or Postural Difficulties1
- Cerebrospinal Fluid Leakage1
- Meningitis1
- Unspecified Infection1
Recent adverse event reports
The 13 most recent of 13 reports, in the reporter's own words as published by the FDA.
InjuryFeb 6, 2026Obstruction of Flow
InjuryDec 25, 2025Insufficient Device Problem Information; Insufficient Device Problem Information
InjuryNov 21, 2025Insufficient Device Problem Information; Insufficient Device Problem Information
InjurySep 26, 2025Leak/Splash; Leak/Splash
InjuryFeb 21, 2025Fluid/Blood Leak; Fluid/Blood Leak
A PHYSICIAN REPORTED A PERITONEAL CATHETER (ID 823045) WAS IMPLANTED ON (B)(6) 2025. A LEAK WAS OBSERVED FROM THE CATHETER THREE DAYS AFTER IMPLANTATION. A RE-OPERATION WAS PERFORMED; ONLY THE PART THAT WAS LEAKED WAS CUT AND A CONNECTOR WAS USED TO FIX IT. THE DOCTOR ASSUMED THAT THE STAPLER MAY HAVE DAMAGED THE CATHETER.
Patient problems: Insufficient Information
MAUDE report 21432802 ↗InjuryFeb 14, 2025Insufficient Device Problem Information; Insufficient Device Problem Information
InjuryNov 15, 2024Migration; Migration
A PHYSICIAN REPORTED A PERITONEAL CATHETER (ID 823045) WAS IMPLANTED DUE TO SECONDARY NORMAL PRESSURE HYDROCEPHALUS (SNPH) VIA VENTRICULOPERITONEAL (VP) SHUNT ON SEPTEMBER 23, 2022, WITH SETTING 1. THE PATIENT HAD DEVELOPED VENTRICULAR DILATATION. THE PERITONEAL CATHETER RUPTURED IN THE CONNECTING PART OF THE VALVE, AND IT WAS NOT LIGATED. THE CATHETER HAD FALLEN OF IN THE ABDOMEN. DUE TO THE ISSUE, THE CATHETER WAS REMOVED AND REPLACED ON (B)(6) 2024. THE PATIENT RECOVERED. THE PATIENT PRIMARY DISEASE IS SUBARACHNOID HEMORRHAGE. ACCORDING TO INFORMATION PROVIDED, IT IS UNKNOWN IF THE PATIENT EXPERIENCED ANY ADDITIONAL SIGNS AND SYMPTOMS.
Patient problems: Cerebral Ventriculomegaly
MAUDE report 20694728 ↗InjuryJun 8, 2024Obstruction of Flow; Obstruction of Flow
A PHYSICIAN REPORTED A HAKIM PERITONEAL CATHETER (ID 823045) WAS IMPLANTED DUE TO IDIOPATHIC NORMAL-PRESSURE HYDROCEPHALUS (INPH) VIA LUMBOPERITONEAL (LP) SHUNT ON (B)(6) 2023 WITH SETTING 5. THE VALVE WAS USED WITH THE SILASCON LUMBAR CATHETER (MANUFACTURED BY KANEKA, PRODUCT CODE: 702-JJ) AND CERTAS PLUS VALVE (ID 828804). THE DOCTOR SUSPECTED THAT THE VALVE HAD FLIPPED, SO THEY ADMINISTERED A LOCAL ANESTHESIA AND FIXED THE VALVE IN ITS ORIGINAL POSITION. DURING THE PROCEDURE, THEY TRIED TO PUMP, BUT THE RESERVOIR REMAINED UNCHANGED. DUE TO SUSPICION OF OBSTRUCTION, PERITONEAL CATHETER, SILASCON AND CERTAS VALVE WERE REMOVED ON (B)(6) 2024. BASED ON INFORMATION PROVIDED, IT IS UNKNOWN IF THE PATIENT EXPERIENCED ANY SIGNS OR SYMPTOMS DUE TO THE REPORTED ISSUE. IT IS NOT KNOWN WHEN THE NEW DEVICE WILL BE IMPLANTED.
Patient problems: Insufficient Information
MAUDE report 19494575 ↗InjuryJun 5, 2024Fluid/Blood Leak; Fluid/Blood Leak
A PHYSICIAN REPORTED A PERITONEAL CATHETER (B)(6) WAS IMPLANTED VIA LUMBOPERITONEAL (L-P) SHUNT DUE TO VENTRICULAR DILATATION 6 MONTHS AGO. ON AN UNKNOWN DATE, A LEAK AND INFECTION WERE NOTED. THE CAUSE OF INFECTION WAS DUE TO A LEAKAGE FROM THE PART WHERE A LUMBAR PUNCTURE WAS PERFORMED. THE CATHETER WAS USED ALONG WITH THE CERTAS VALVE (B)(6) PRODUCTS WERE REMOVED AND REPLACED BY AN EXTERNAL VENTRICULAR DRAINAGE SYSTEM. BASED ON INFORMATION PROVIDED, IT IS UNKNOWN WHICH DEVICE WAS REMOVED, IT IS ALSO UNKNOWN THE TYPE OF INFECTION/ORGANISM AND THE TESTS USED TO CONFIRM IT. THE TREATMENT OR MEDICATION USED TO TREAT THE INFECTION IS UNKNOWN. PRIMARY DISEASE: SECONDARY NORMAL PRESSURE HYDROCEPHALUS (SNPH).
Patient problems: Cerebral Ventriculomegaly; Cerebrospinal Fluid Leakage; Unspecified Infection
MAUDE report 19466934 ↗InjuryApr 12, 2024Obstruction of Flow; Obstruction of Flow
THIS IS 2 OF 2 REPORTS LINKED TO MFG REPORT NUMBER 3013886523-2024-00115: A FACILITY REPORTED THAT THE HAKIM PERITONEAL CATHETER (823045) WAS EXPLANTED DUE TO SUSPICION OF OBSTRUCTION. THE PRESSURE SETTING ON THE VALVE WAS CHANGEABLE. THE IMPLANT AND EXPLANT DATES ARE UNKNOWN, AND PATIENT INFORMATION IS ALSO UNKNOWN. THERE WAS NO SURGICAL DELAY. REOPERATION WAS PERFORMED ON AN UNKNOWN DATE.
Patient problems: Insufficient Information
MAUDE report 19101919 ↗InjuryNov 22, 2023Fluid/Blood Leak; Infusion or Flow Problem; Fluid/Blood Leak; Infusion or Flow Problem
InjurySep 13, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
THIS IS 2 OF 2 REPORTS LINKED TO MFG REPORT NUMBERS: 3013886523-2023-00314 A PHYSICIAN REPORTED A CERTAS VALVE (828804) WAS IMPLANTED VIA LUMBAR PERITONEAL (LP) SHUNT ON (B)(6) 2022 WITH SETTING 2. THE VALVE WAS USED WITH THE SILASCON® LUMBAR CATHETER (MANUFACTURED BY KANEKA, PRODUCT CODE: 702-JJ), AND PERITONEAL CATHETER (823045) WITH UNKNOWN SERIAL NUMBER. ON (B)(6) 2022, THE PATIENT'S SYMPTOMS WORSENED. AN ENLARGEMENT OF THE VENTRICLES AND SUBCUTANEOUS CEREBROSPINAL FLUID RETENTION WERE CONFIRMED. THE PATIENT WAS DIAGNOSED WITH MENINGITIS. THE SETTING WAS CHANGED FROM 2 TO 1, HOWEVER THE PATIENT'S HYDROCEPHALUS DID NOT IMPROVE. ON (B)(6) 2023, THE SHUNT SYSTEM WAS REMOVED. WHEN THE CATHETER WAS REMOVED FROM THE ABDOMINAL CAVITY WITH THE VALVE AND LUMBAR CATHETER LEFT IN PLACE, THE RESERVOIR REMAINED DEPRESSED AND DID NOT RETURN DESPITE PUMPING. THERE WERE NO OBSTRUCTIONS OF THE LUMBAR CATHETER AND ABDOMINAL CATHETER. THE PATIENT IS CURRENTLY UNDER OBSERVATION WITH VENTRICULAR DRAINAGE. THE VALVE WAS REMOVED ON (B)(6) 2023 AND WAS NOT REPLACED. ACCORDING TO INFORMATION PROVIDED, IT IS UNKNOWN IF THERE IS AN OBSTRUCTION WITH THE VALVE. IT IS ALSO UNKNOWN IF THE INFECTION IS RELATE
Patient problems: Meningitis
MAUDE report 17741050 ↗InjurySep 12, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
THIS IS 2 OF 2 REPORTS LINKED TO MFG REPORT NUMBERS: 3013886523-2023-00305. A PHYSICIAN REPORTED A CERTAS VALVE (ID 828804) AND A HAKIM PERITONEAL CATHETER (ID 823045) WERE IMPLANTED VIA LUMBAR PERITONEAL SHUNT ON UNKNOWN DATE WITH UNKNOWN SETTING. ON (B)(6) 2023, GAIT DISORDER WAS OBSERVED AND OBSTRUCTION WAS SUSPECTED. THE VALVE AND HAKIM CATHETER WERE REMOVED AND REPLACED ON (B)(6) 2023. THE PATIENT RECOVERED. ACCORDING TO INFORMATION PROVIDED, IT IS UNKNOWN IF THE HAKIM CATHETER FAILED, HOWEVER IT WAS EXPLANTED.
Patient problems: Ambulation or Postural Difficulties
MAUDE report 17729557 ↗
Other Shunt, central nervous system and components devices
- NATUS EDS3 DRAINAGE SYSTEM NT821731CNatus Medical Incorporated · Shunt, Central Nervous System And Components1 recall208 reports
- Exacta™ 46700Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall2 deaths163 reports
- Strata® 42866Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 death160 reports
- proGAV 2.0® FX410TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components119 reports
- PROGAV 2.0 FX643TAesculap AG · Shunt, central nervous system and components100 reports
- Becker® 46128Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall50 reports
- M.BLUE PLUS FX804TAesculap AG · Shunt, central nervous system and components82 reports
- proSA® FV701TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components82 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page