CODMAN® HAKIM® 825465Recalls & reported problems

Integra Lifesciences Production Corporation · Precision Fixed Pressure Valve In-Line Valve with SIPHONGUARD® Device High Range · Class 2 · Implant

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10381780535201), received between Sep 5, 2025 and Sep 5, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Illegible Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Illegible Information1
  • Use of Device Problem1

Patient problems

  • Lethargy1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjurySep 5, 2025Use of Device Problem; Illegible Information; Use of Device Problem; Illegible Information

    A FACILITY REPORTED: "A 5-YEAR-OLD PATIENT UNDERWENT SHUNT REVISION ON (B)(6) 2024 FOR RADIOLOGICAL AND CLINICAL SHUNT FAILURE. UNEVENTFUL PROCEDURE AND RECOVERED WELL OVER THE FOLLOWING DAYS. CLINICAL DETERIORATION ON (B)(6) 2024 AND SCAN DEMONSTRATED VENTRICLES ENLARGED. THEREFORE, WENT FOR ANOTHER SHUNT EXPLORATION WHICH DEMONSTRATED A NON-FUNCTIONING VALVE WHICH WAS A FIXED HIGH-PRESSURE VALVE WITH ANTISIPHON, AS OPPOSED TO A FIXED MEDIUM-LOW PRESSURE VALVE WITH ANTISIPHON. THEREFORE, THE WRONG VALVE WAS INSERTED IN THE FIRST SHUNT REVISION AND THE PATIENT REQUIRED A FURTHER PROCEDURE TO CORRECT THIS." "THERE WAS NOTHING WRONG WITH THE IMPLANT, BUT THE WRONG IMPLANT WAS INSERTED. IT IS NOT FELT TO HAVE BEEN DIRECTLY CAUSATIVE OF THIS ERROR, BUT THE LABELLING ON THE PACKAGING THAT IDENTIFIES THE TYPE OF SHUNT AND ITS PROPERTIES IS IN VERY SMALL PRINT." ADDITIONAL INFORMATION: - WHICH REFERENCE/TYPE OF VALVE WAS SUPPOSED TO BE IMPLANTED INITIALLY? "833283 MEDIUM -LOW PRESSURE". - IT WAS MENTIONED CLINICAL DETERIORATION ON (B)(6) 2024 AND SCAN DEMONSTRATED VENTRICLES ENLARGED. WHAT ARE THE CONSEQUENCES/SYMPTOMS FOR PATIENT HEALTH? "LETHARGY (IN A PATIENT WITH ALREADY REDUCED CONSC

    Patient problems: Lethargy

    MAUDE report 22978141 ↗

Other Shunt, central nervous system and components devices

All Shunt, central nervous system and components devices →