CODMAN® CERTAS® Plus 828807PLRecalls & reported problems

Integra LifeSciences Switzerland Sàrl · CODMAN CERTAS® Plus Programmable Valve Inline Valve with SIPHONGUARD®, Accessories and Unitized BACTISEAL® Catheter Includes: BACTISEAL Ventricular Catheter, BACTISEAL Unitized Distal Catheter, Priming Adapter, Right Angle Adapter and Information Manual · Class 2 · Implant

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10381780535430), received between Aug 7, 2026 and Aug 7, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Improper Flow or Infusion” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Improper Flow or Infusion1

Patient problems

  • Headache1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 7, 2026Improper Flow or Infusion

    A sales representative stated:"Patient is a 68-year-old man with normal pressure hydrocephalus. He was shunted in December 2025 and has been having unpredictable responses to valve changes ever since. Patient had subdurals that had to be managed, but not surgically. Recently, his ventricles had collapsed down with small extra axial collections. The physician turned the valve off to 8 and his ventricles remained collapsed with small extra axial collections. He was neurologically doing very well but was having low pressure headaches.""The physician assumed that the valve was defective now that it was set at 8 and the ventricles were not filling up. He felt the valve was probably just staying open and continued to drain. Ultimately, with the postural headaches continuing, the physician really didn't like looking at slit ventricles and small axials so with the hypothesis of the defective valve, the valve being stuck open, despite being set at 8, the physician put him on the schedule to replace what he thought was a defective valve. That was scheduled for next week, but yesterday on (b)(6), he came in with asymptomatic hydro. Images were close to his pre-op scan. The physician reprogram

    Patient problems: Headache

    MAUDE report 50175253 ↗

Other Shunt, central nervous system and components devices

All Shunt, central nervous system and components devices →